FM36 Operator list: Difference between revisions
Appearance
mNo edit summary |
mNo edit summary |
||
| (2 intermediate revisions by the same user not shown) | |||
| Line 3: | Line 3: | ||
Roaming Operator Codes are written.<br /> | Roaming Operator Codes are written.<br /> | ||
X defines starting position that is changed: If X is from 0 to 49, X means index of operator | X defines starting position that is changed: If X is from 0 to 49, X means index of operator | ||
code which has to be configured. Up to 20 operator codes may be configured in 1 SMS. Example: | code which has to be configured. Up to 20 operator codes may be configured in 1 SMS. Example:<br /> | ||
setparam 1271 16 24602,24603,24605<br /> | " ''setparam 1271 16 24602,24603,24605''"<br /> | ||
Here 16<sup>th</sup>, 17<sup>th</sup> and 18<sup>th</sup> operator codes are set. '''Note! Other operator codes are left unchanged in the configuration'''.<br /> | Here 16<sup>th</sup>, 17<sup>th</sup> and 18<sup>th</sup> operator codes are set. '''Note! Other operator codes are left unchanged in the configuration'''.<br /> | ||
{| class="wikitable" | |||
|+ | |||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Parameter ID''' | |||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Parameter Type''' | |||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Default value''' | |||
! style="width: 150px; background: black; color: white;" colspan=2 |'''Value range''' | |||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Value''' | |||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Parameter name''' | |||
|- | |||
! style="width: 75px; background: black; color: white;" |Min | |||
! style="width: 75px; background: black; color: white;" |Max | |||
|- | |||
! style="text-align: center; vertical-align: center;" |[[FM36_Operator_list|1271]] | |||
| style="text-align: center; vertical-align: center;" |U32 | |||
| style="text-align: center; vertical-align: center;" |"" | |||
| style="text-align: center; vertical-align: center;" |Empty | |||
| style="text-align: center; vertical-align: center;" |7 digits | |||
| style="text-align: center; vertical-align: center;" | | |||
| style="text-align: center; vertical-align: center;" |Name | |||
|- | |||
Latest revision as of 12:55, 4 June 2018
Parameter defines operator list. According to this list module selects operating profile.
GSM operator codes are comma separated. First in a list is Home Operator Code, then Preferred
Roaming Operator Codes are written.
X defines starting position that is changed: If X is from 0 to 49, X means index of operator
code which has to be configured. Up to 20 operator codes may be configured in 1 SMS. Example:
" setparam 1271 16 24602,24603,24605"
Here 16th, 17th and 18th operator codes are set. Note! Other operator codes are left unchanged in the configuration.
| Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 1271 | U32 | "" | Empty | 7 digits | Name | |