Template:FMB First start config: Difference between revisions

From Teltonika Telematics Wiki
No edit summary
No edit summary
 
(73 intermediate revisions by 15 users not shown)
Line 1: Line 1:
=='''How to install {{{model|FMB1YX}}} drivers (Windows)'''==
{{{PCConnection|
===PC Connection (Windows)===


1. Please download COM port drivers from Teltonika '''[https://teltonika.lt/downloads/en/fmb120/TeltonikaCOMDriver.zip here]'''.
{{{fmb_powerup|# Power-up {{{model|FMB1YX}}} with '''DC voltage {{{dc_voltage|(10 – 30 V)}}}''' power supply {{{additional_power_supply|}}} using '''{{{power_cable|supplied power cable}}}'''. LED’s should start blinking, see “'''{{{led_status_link|LED behaviour description}}}'''”.}}}
# Connect device to computer using '''{{{usb_cable|Micro-USB}}} cable'''{{{Bluetooth®_connection| or '''Bluetooth®''' connection:
#* Using '''{{{usb_cable|Micro-USB}}} cable'''
#** You will need to install USB drivers, see "[[#How to install USB drivers (Windows)|'''How to install USB drivers (Windows)''']]"
#* Using '''Bluetooth®'''
#** {{{model|FMB1YX}}} Bluetooth® is enabled by default. Turn on '''Bluetooth®''' on your PC, then select '''Add Bluetooth® or other device > Bluetooth®'''. Choose your device named – “'''{{{model|FMB1YX}}}_last_7_imei_digits'''”, without '''LE''' in the end. Enter default password '''5555''', press '''Connect''' and then select '''Done'''.}}}
# You are now ready to use the device on your computer.
}}}
===How to install USB drivers (Windows)===


2. Extract and run '''TeltonikaCOMDriver.exe'''. This driver is used to control {{{model|FMB1YX}}} device when it is connected to the computer.
# Please download COM port drivers from '''[[Media:TeltonikaCOMDriver.zip|here]]'''.
# Extract and run '''TeltonikaCOMDriver.exe'''.
# Click '''Next''' in driver installation window.
# In the following window click '''Install''' button.
# Setup will continue installing the driver and eventually the confirmation window will appear. Click '''Finish''' to complete the setup.


3. Click '''Next''' in driver installation window.
===Configuration (Windows)===


4. In the following window click '''Install''' button.
At first {{{model|FMB1YX}}} device will have default factory settings set. These settings should be changed according to the user's needs.<br/>
 
Main configuration can be performed via '''[[Teltonika Configurator]]''' software. Get the latest {{{model|FMB1YX}}} '''Configurator''' version from '''[[{{{SAS_Configurator_Versions|Teltonika Configurator versions}}}|here]]'''. Configurator operates on Microsoft Windows OS and uses prerequisite MS .NET Framework. Make sure you have the correct version installed.
5. Setup will continue installing the driver and eventually the confirmation window will appear. Click '''Finish''' to complete the setup. You are now ready to use the device on your computer.
 
=='''Configuration (Windows)'''==


{| class="wikitable"
{| class="wikitable" style="width:50%;"
|+.NET requirements
|+
! style="background: white;"         | Operating system
! colspan="4" style="width:50%; border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: left;"| MS .NET requirements
! style="background: white;"         | MS .NET Framework version
! style="background: white;"        | Version
! style="background: white;"         | Links
|-
|-
| style="text-align: left; background: #F6F6FB;"         | Windows Vista<br/>Windows 7<br/>Windows 8.1<br/>Windows 10
! style="width:10%; border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: left;"| Operating system
| style="text-align: left; background: #F6F6FB;"         | MS .NET Framework 4.6.2
! style="width:25%; border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: left;"| MS .NET Framework version
| style="text-align: left; background: #F6F6FB;"         | 32 and 64 bit
! style="width:10%; border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: left;"| Version
| style="text-align: left; background: #F6F6FB;"         | [https://www.microsoft.com/en-us/download/confirmation.aspx?id=53344 Microsoft.com]
! style="width:5%; border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: left;"| Link
[http://avl1.teltonika.lt/downloads/software/Framework/.NET%20Framework%204.6.2/NDP462-KB3151800-x86-x64-AllOS-ENU.exe  Teltonika.lt]
|-
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" | <ul style="list-style: none; margin: 0px;">
<li>Windows Vista</li>
<li>Windows 7</li>
<li>Windows 8.1</li>
<li>Windows 10</li>
</ul>
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" | {{{MS .NET Framework|MS .NET Framework 5.0}}}
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" | 32 and 64 bit
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" | {{{MS .NET Framework link|[https://dotnet.microsoft.com/en-us/download/dotnet-framework/net462 .NET Framework]}}}
|}
|}


At first {{{model|FMB1YX}}} device will have default factory settings set. These settings should be changed according to the user's needs.<br/>
Downloaded '''Configurator''' will be in compressed archive. Extract it and launch '''Configurator.exe'''. After launch software language can be changed by clicking [[File:Language_logo.png|25px|link=]] in the right bottom corner:
Device can be configured to acquire and send data to server, in this case the GSM settings shall be set in regards with GSM operator's information. If device GSM is unavailable, the device will not be able to send the data and {{{model|FMB1YX}}} will start storing records to flash memory. It is possible to store up to 192000 data records with {{{txt_memory|128 MB SD memory card}}} (when 100 MB are used to store records). It will send data over GPRS when it is available. Note that {{{model|FMB1YX}}} might reach its full memory capacity. If such case happens, the device will start deleting the oldest records in order to save new ones.<br/>
 
{{{model|FMB1YX}}} configuration is performed via {{{model|FMB1YX}}} Configurator program. Contact sales manager to get the latest {{{model|FMB1YX}}} Configurator version or download from '''[https://teltonika.lt/downloads/en/fmb900/FMB.Configurator_v0.14.5.27701_C.001.7z here]'''. {{{model|FMB1YX}}} configurator operates on Microsoft Windows OS and uses prerequisite MS .NET Framework.
[[File:FMB_Configurator_languag.jpg|400px]]
 
Configuration process begins by pressing on connected device:
 
[[File:{{{cfg_connect|Configurator_connect-FMB150.jpg}}}|400px]]
 
After connection to Configurator '''Status window''' will be displayed:
{{{Status window image|[[Image:{{{model|FMB120}}} Beacon-info-{{{family|FMB1}}} series.png|1000px|none]]}}}
 
 
Various '''[[{{{model|FMB1YX}}}_Status_info|Status window]]''' tabs display information about '''[[{{{model|FMB1YX}}}_Status_info#GNSS_Info|GNSS]], [[{{{model|FMB1YX}}}_Status_info#GSM_Info|GSM]], [[{{{model|FMB1YX}}}_Status_info#I.2FO_Info|I/O]], [[{{{model|FMB1YX}}}_Status_info#Maintenance|Maintenance]]''' and etc. {{{model|FMB1YX}}} has one user editable profile, which can be loaded and saved to the device. After any modification of configuration the changes need to be saved to device using '''Save to device''' button. Main buttons offer following functionality:<br/>
# [[File:Load_from_device.png|25px|link=]] '''Load from device''' – loads configuration from device.
# [[File:Save_to_device.png|25px|link=]] '''Save to device''' – saves configuration to device.
# [[File:Load_from_file.png|25px|link=]] '''Load from file''' – loads configuration from file.
# [[File:Save_to_file.png|25px|link=]] '''Save to file''' – saves configuration to file.
# {{{Firmware_button| [[File:Firmware_update.png|25px|link=]] '''Update firmware''' – updates firmware on device.}}}
# [[File:Read_records.png|25px|link=]] '''Read records''' – read records from device.
# [[File:Reboot_device.png|25px|link=]] '''Reboot device''' – restarts device.
# [[File:Reset_configuration.png|25px|link=]] '''Reset configuration''' – sets device configuration to default.
 
Most important configurator section is GPRS – where all your server and '''[[{{{model|FMB1YX}}}_GPRS_settings|GPRS settings]]''' can be configured and '''[[{{{model|FMB1YX}}}_Data_acquisition_settings|Data Acquisition]]''' – where data acquiring parameters can be configured.
More details about {{{model|FMB1YX}}} configuration using Configurator can be found '''{{{config_link|in the manual}}}'''.
 
===Quick SMS configuration===
 
Default configuration has optimal parameters present to ensure best performance of track quality and data usage.<br/>
Quickly set up your device by sending this SMS command to it:
 
"  setparam <span style="background-color:#91b9d4;">2001</span>:APN;<span style="background-color:#91d4b9;">2002</span>:APN_username;<span style="background-color:#b991d4;">2003</span>:APN_password;<span style="background-color:#b9d491;">2004</span>:Domain;<span style="background-color:#d491b9;">2005</span>:Port;<span style="background-color:#d4b991;">2006</span>:0"
 
<div style="column-count:2;-moz-column-count:2;-webkit-column-count:2">
GPRS settings:
* <span style="background-color:#91b9d4;">2001</span> – APN
* <span style="background-color:#91d4b9;">2002</span> – APN username (if there are no APN username, empty field should be left)
* <span style="background-color:#b991d4;">2003</span> – APN password (if there are no APN password, empty field should be left)
Server settings:
* <span style="background-color:#b9d491;">2004</span> – Domain
* <span style="background-color:#d491b9;">2005</span> – Port
* <span style="background-color:#d4b991;">2006</span> – Data sending protocol (0 – TCP, 1 – UDP)
</div>
 
'''Note''': Before SMS text, two space symbols should be inserted.<br/><br/>
[[File:IOS sms cfg.png|235px|right]]


[[Image:{{{first_time|Fmb120_configurator.png}}}|1200px|none]]
{{{quick_sms_tmt|<table style="width:70%">
Module configuration can be performed over USB cable or using a Blue-tooth connection. Configuration process begins by starting {{{model|FMB1YX}}} Configurator software and then connecting to {{{model|FMB1YX}}} device via '''Connect''' button located in '''Online''' menu part. {{{model|FMB1YX}}} has one user editable profile, which can be loaded and saved to the device. After any modification of configuration the changes need to be saved to {{{model|FMB1YX}}} device using '''Save to device''' button.<br/>
  <tr>
Main buttons offer following functionality:<br/>
    <td colspan="4">'''Default configuration settings'''</td>
* '''Load from device''' – loads configuration from device.
  </tr>
* '''Save to device''' – saves configuration to device.
  <tr>
* '''Load from file''' – loads configuration from file.
    <td colspan="4">Movement and ignition detection:</td>
* '''Save to file''' – saves configuration to file.
  </tr>
* '''Update firmware''' – updates firmware on device.
  <tr>
* '''Reset configuration''' – sets device configuration to default.
    <td>[[File:Accelerometer.png|65px]]</td>
    <td>Vehicle movement will be detected by accelerometer</td>
    <td>[[File:Ignition detection-2-2.png|65px]]</td>
    <td>Ignition will be detected by vehicle power voltage between 13,2 – 30 V</td>
  </tr>
  <tr>
    <td colspan="4">Device makes a record '''On Moving''' if one of these events happen:</td>
  </tr>
  <tr>
    <td>[[File:300s_icon_2.png|65px]]</td>
    <td>300 seconds passes</td>
    <td>[[File:Angle_10_2.png|65px]]</td>
    <td>Vehicle turns 10° degrees</td>
  </tr>
  <tr>
    <td>[[File:Min_distance.png|65px]]</td>
    <td>Vehicle drives 100 meters</td>
    <td>[[File:Speed_delta.png|65px]]</td>
    <td>Speed difference between last coordinate and current position is greater than 10 km/h</td>
  </tr>
  <tr>
    <td colspan="4">Device makes a record '''On Stop''' if:</td>
  </tr>
  <tr>
    <td>[[File:1h_icon.png|65px]]</td>
    <td>1 hour passes while vehicle is stationary and ignition is off</td>
  </tr>
  <tr>
    <td colspan="4">Records sending to server:</td>
  </tr>
  <tr>
    <td>[[File:120_s.png|65px]]</td>
    <td>If device has made a record it is sent to the server every 120 seconds</td>
  </tr>
</table>}}}


More details on using the Configurator can be found {{{config_link|in the manual}}}.
<br/>
<p>After successful SMS configuration, {{{model|FMB1YX}}} device will '''synchronize time''' and '''update records''' to '''configured server'''. Time intervals and default I/O elements can be changed by using [[Teltonika Configurator]] or {{{SMS/GPRS Commands|[[Template:FMB Device Family Parameter list|SMS parameters]]}}}.</p>

Latest revision as of 12:01, 15 December 2023

PC Connection (Windows)

  1. Power-up FMB1YX with DC voltage (10 – 30 V) power supply using supplied power cable. LED’s should start blinking, see “LED behaviour description”.
  2. Connect device to computer using Micro-USB cable or Bluetooth® connection:
    • Using Micro-USB cable
    • Using Bluetooth®
      • FMB1YX Bluetooth® is enabled by default. Turn on Bluetooth® on your PC, then select Add Bluetooth® or other device > Bluetooth®. Choose your device named – “FMB1YX_last_7_imei_digits”, without LE in the end. Enter default password 5555, press Connect and then select Done.
  3. You are now ready to use the device on your computer.

How to install USB drivers (Windows)

  1. Please download COM port drivers from here.
  2. Extract and run TeltonikaCOMDriver.exe.
  3. Click Next in driver installation window.
  4. In the following window click Install button.
  5. Setup will continue installing the driver and eventually the confirmation window will appear. Click Finish to complete the setup.

Configuration (Windows)

At first FMB1YX device will have default factory settings set. These settings should be changed according to the user's needs.
Main configuration can be performed via Teltonika Configurator software. Get the latest FMB1YX Configurator version from here. Configurator operates on Microsoft Windows OS and uses prerequisite MS .NET Framework. Make sure you have the correct version installed.

MS .NET requirements
Operating system MS .NET Framework version Version Link
  • Windows Vista
  • Windows 7
  • Windows 8.1
  • Windows 10
MS .NET Framework 5.0 32 and 64 bit .NET Framework

Downloaded Configurator will be in compressed archive. Extract it and launch Configurator.exe. After launch software language can be changed by clicking in the right bottom corner:

Configuration process begins by pressing on connected device:

After connection to Configurator Status window will be displayed:


Various Status window tabs display information about GNSS, GSM, I/O, Maintenance and etc. FMB1YX has one user editable profile, which can be loaded and saved to the device. After any modification of configuration the changes need to be saved to device using Save to device button. Main buttons offer following functionality:

  1. Load from device – loads configuration from device.
  2. Save to device – saves configuration to device.
  3. Load from file – loads configuration from file.
  4. Save to file – saves configuration to file.
  5. Update firmware – updates firmware on device.
  6. Read records – read records from device.
  7. Reboot device – restarts device.
  8. Reset configuration – sets device configuration to default.

Most important configurator section is GPRS – where all your server and GPRS settings can be configured and Data Acquisition – where data acquiring parameters can be configured. More details about FMB1YX configuration using Configurator can be found in the manual.

Quick SMS configuration

Default configuration has optimal parameters present to ensure best performance of track quality and data usage.
Quickly set up your device by sending this SMS command to it:

"  setparam 2001:APN;2002:APN_username;2003:APN_password;2004:Domain;2005:Port;2006:0"

GPRS settings:

  • 2001 – APN
  • 2002 – APN username (if there are no APN username, empty field should be left)
  • 2003 – APN password (if there are no APN password, empty field should be left)

Server settings:

  • 2004 – Domain
  • 2005 – Port
  • 2006 – Data sending protocol (0 – TCP, 1 – UDP)

Note: Before SMS text, two space symbols should be inserted.

Default configuration settings
Movement and ignition detection:
Vehicle movement will be detected by accelerometer Ignition will be detected by vehicle power voltage between 13,2 – 30 V
Device makes a record On Moving if one of these events happen:
300 seconds passes Vehicle turns 10° degrees
Vehicle drives 100 meters Speed difference between last coordinate and current position is greater than 10 km/h
Device makes a record On Stop if:
1 hour passes while vehicle is stationary and ignition is off
Records sending to server:
If device has made a record it is sent to the server every 120 seconds


After successful SMS configuration, FMB1YX device will synchronize time and update records to configured server. Time intervals and default I/O elements can be changed by using Teltonika Configurator or SMS parameters.