Main Page > Basic Trackers > FTC921 > FTC921 Teltonika Data Sending Parameters ID
FTC AVL ID's consist of these parameters groups:
Permanent I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
239 | Ignition | 1 | Unsigned | 0 | 1 | - | - |
0 – Ignition Off |
Permanent I/O Elements | |
240 | Movement | 1 | Unsigned | 0 | 1 | - | - |
0 – Movement Off |
Permanent I/O Elements | |
303 | Instant Movement | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 returns movement value | Permanent I/O elements | |
21 | GSM Signal | 1 | Unsigned | 0 | 5 | - | - |
Value in range 1-5 |
Permanent I/O Elements | |
800 | External Voltage | 4 | Unsigned | 0 | 150000 | 0.001 | V |
Voltage |
Permanent I/O elements | |
205 | GSM Cell ID | 2 | Unsigned | 0 | 65535 | - | - |
GSM base station ID |
Permanent I/O elements | |
206 | GSM Area Code | 2 | Unsigned | 0 | 65535 | - | - |
Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations. |
Permanent I/O elements | |
237 | Network Type | 1 | Unsigned | 0 | 1 | - | - | 0 - 3G
1 - GSM |
Permanent I/O elements | |
67 | Battery Voltage | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Voltage |
Permanent I/O elements | |
68 | Battery Current | 2 | Unsigned | 0 | 65535 | 0.001 | A |
Current |
Permanent I/O elements | |
199 | Trip Odometer | 4 | Unsigned | 0 | 2147483647 | - | m |
Trip Odometer value |
Permanent I/O elements | |
16 | Total Odometer | 4 | Unsigned | 0 | 2147483647 | - | - |
Total Odometer value in meters |
Permanent I/O elements | |
1 | Digital Input 1 | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
9 | Analog Input 1 | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Voltage |
Permanent I/O elements | |
249 | Digital Output 1 Overcurrent | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
641 | ICCID | 22 | ASCII | 0 | 22 | - | - |
Value of SIM ICCID |
Permanent I/O elements |
Eventual I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
249 | Jamming detection | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Eventual I/O elements | |
250 | Trip | 1 | Unsigned | 0 | 1 | - | - |
0 – trip stop |
Eventual I/O elements | |
255 | Over Speeding | 1 | Unsigned | 0 | 255 | - | km/h |
At over speeding start km/h, at over speeding end km/h |
||
251 | Idling | 1 | Unsigned | 0 | 1 | - | - |
0 – moving |
Eventual I/O elements | |
253 | Green driving type | 1 | Unsigned | 1 | 3 | - | - |
1 – harsh acceleration |
Eventual I/O elements | |
254 | Green Driving Value | 1 | Unsigned | 0 | 255 | acc and braking: 0.01 | G or rad |
Depending on green driving type: if harsh acceleration or braking – g*100 (value 123 -> 1.23g). If Green driving source is „GPS“ – harsh cornering value is rad/s*100. If source is „Accelerometer“ – g*100. |
|
Eventual I/O elements |