TeraCom-TSH202: Difference between revisions
Ahmed Hossam (talk | contribs) (Created page with "thumb|400px|TeraCom TSH202 ==Introduction== TeraCom TSH202 is humidity and temperature sensors with a 1-Wire interface. The...") |
Ahmed Hossam (talk | contribs) No edit summary |
||
(2 intermediate revisions by the same user not shown) | |||
Line 90: | Line 90: | ||
#Use | #Use '''Firmware ver.03.27.13.Rev.480.e''' and above. | ||
#Use '''Teltonika.Configurator_1.7.30_E.THS202_R.4''' | #Use '''Teltonika.Configurator_1.7.30_E.THS202_R.4''' and above. | ||
===With FMB120:=== | ===With FMB120:=== | ||
Line 101: | Line 101: | ||
[[File:TSH202-FMC130.mp4|none|thumb|1920x1080px]] | [[File:TSH202-FMC130.mp4|none|thumb|1920x1080px]] | ||
'''''<span style="color:blue"><b><nowiki>*</nowiki>''' The used Firmware is tested with '''TSH202v3 | '''''<span style="color:blue"><b><nowiki>*</nowiki>''' The used Firmware is tested with '''TSH202v3 model'''.</b></span>'' | ||
==Demonstration in Flespi platform== | ==Demonstration in Flespi platform== |
Latest revision as of 15:25, 12 June 2023
Main Page > Accessories > TeraCom-TSH202Introduction
TeraCom TSH202 is humidity and temperature sensors with a 1-Wire interface. The device integrates basic elements plus signals processing, and provides a fully calibrated digital output. A unique capacitive element is used for measuring relative humidity while the temperature is measured by a band gap sensor. Both sensors are seamlessly coupled to a 12-bit analog to digital converter. This results in superior signal quality and fast response time.
Applications
- Server room and data centers monitoring.
- Environmental quality monitoring and assessment.
- Humidity and temperature monitoring in building management systems.
- Humidity and temperature monitoring for mobile operator facilities, vineyards, greenhouses, etc.
Technical parameters
NAME | DESCRIPTION |
---|---|
Interface | 1-Wire Interface |
Wiring | White = 1-wire signal, Red = 1-wire power, Black = Ground |
* Operating temperature | -20 ºC to +60 ºC |
* Operating humidity | 10 to 90%RH |
Tolerance typ. | ±3.0 %RH (20 to 80 %RH), ±0.4 °C (-10 to +60°C) |
Tolerance max. | ±5.0 %RH (10 to 90) %RH, ±1.0 °C (-20 to +60°C) |
Power supply/consumption | 4.0 to 5.5 VDC, 5 mA |
Dimensions | 45 x 16 x 10 |
Cable length | 1 m |
* Recommended operating range is 20% to 80% RH (non-condensing) over -10°C to +60°C.
Prolonged operation beyond these ranges may result in a shift of sensor reading, with slow recovery time.
Installation
- TSH202 will be connected with FM devices via 1-wire interface.
- To connect the 1-wire TSH202 sensor you have to make sure to connect 3 PINs of the sensor to the PINs of your device correctly.
Connections
We tested TSH202 sensor with FMB120 & FMC130 devices and connections will be as per following sequence.
TSH202 wire color | Connections |
---|---|
Red | +VDD (+4.0 to +5.5V) 1-wire power of FM device |
White | 1-wire signal of FM device |
Black | Ground of FM device |
Configuration
- Use Firmware ver.03.27.13.Rev.480.e and above.
- Use Teltonika.Configurator_1.7.30_E.THS202_R.4 and above.
With FMB120:
With FMC130:
* The used Firmware is tested with TSH202v3 model.
Demonstration in Flespi platform
Flespi: Open Flespi application → Select Device → Select Logs & Messages → Select the record interval → Tap to see all information.
With FMB120:
With FMC130:
Downloads
Manual & Documentation
1-Wire humidity and temperature sensor TSH202 brochure(v1.10)