| Line 1: | Line 1: | ||
{{Template:FMB I/O settings|model=FMB125}} | {{Template:FMB I/O settings|model=FMB125|ctrIO=[https://wiki.teltonika-gps.com/index.php?title=FMB125_I/O_settings I/O settings]|ctrCAN=[[FMB120 CAN adapters|FMB125 with LV-CAN200 and ALL-CAN300 CAN adapters]] | ||
|sms_text_tmt= | |||
}} | |||
==FMB125 RS-232/RS-485 parameter configuration== | ==FMB125 RS-232/RS-485 parameter configuration== | ||
FMB-125 supports RS-232 and RS-485 serial standards and can be configured to work in different RS-232/RS-485 modes. More information about each mode is provided in [[FMB125 RS-232 and RS-485|RS-232 and RS-485]].<br/>Only one mode may be selected | |||
[[Image:Fmb125_uart_mode.png|300px|right]] | |||
FMB-125 supports RS-232 and RS-485 serial standards and can be configured to work in different RS-232/RS-485 modes. More information about each mode is provided in [[FMB125 RS-232 and RS-485|RS-232 and RS-485]].<br/>Only one mode may be selected at a time: | |||
* <span style=color:#F6A83E>Disable</span> - Disable RS-232/RS-485 functionality; | * <span style=color:#F6A83E>Disable</span> - Disable RS-232/RS-485 functionality; | ||
* <span style=color:#F6A83E>RS232</span> - Select RS-232 functionality; | * <span style=color:#F6A83E>RS232</span> - Select RS-232 functionality; | ||
| Line 8: | Line 12: | ||
===RS-232 modes=== | ===RS-232 modes=== | ||
---- | |||
RS-232 supports following modes: | RS-232 supports following modes: | ||
* <span style=color:#F6A83E>Log Mode</span> – suitable for debugging/logging; | * <span style=color:#F6A83E>Log Mode</span> – suitable for debugging/logging; | ||
| Line 20: | Line 24: | ||
* <span style=color:#F6A83E>TCP Binary</span> – for routing any binary input data from external device to the server. | * <span style=color:#F6A83E>TCP Binary</span> – for routing any binary input data from external device to the server. | ||
====RS-232 | ====RS-232 baudrate and parity==== | ||
Every RS-232 mode supports different baudrates, but each mode has its own default baudrate value. Default baudrate and parity values for each RS-232 mode are provided in the table below. | Every RS-232 mode supports different baudrates, but each mode has its own default baudrate value. Default baudrate and parity values for each RS-232 mode are provided in the table below. | ||
| Line 77: | Line 81: | ||
====RS-232 TCP Binary mode settings==== | ====RS-232 TCP Binary mode settings==== | ||
RS-232 TCP Binary | [[Image:Fmb125_tcp_binary_mode.png|300px|right]] | ||
RS-232 ''TCP Binary mode'' has additional configurable parameters for advanced data filtering as shown on the right hand side figure. | |||
==== | ====RS-232 Garmin mode settings==== | ||
Garmin FMI mode has addditional filtering capabilities. It is possible to filter Ping and Unicode packets. If <span style=color:#F6A83E>Ping Filter</span> | [[Image:Fmb125_garmin_mode.png|300px|right]] | ||
''Garmin FMI mode'' has addditional filtering capabilities. It is possible to filter Ping and Unicode packets. If <span style=color:#F6A83E>Ping Filter</span> is enabled, then Ping packets are blocked. When <span style=color:#F6A83E>Unicode Filter</span> is enabled Unicode packets are not sent to the server. Both filters may be enabled for simultaneous effect.<br/><br/><br/> | |||
===RS-485 modes=== | ===RS-485 modes=== | ||
---- | |||
RS-485 supports several modes: | RS-485 supports several modes: | ||
* <span style=color:#F6A83E>Log Mode</span> – suitable for debugging/logging; | * <span style=color:#F6A83E>Log Mode</span> – suitable for debugging/logging; | ||
| Line 96: | Line 102: | ||
====RS-485 LLS sensors==== | ====RS-485 LLS sensors==== | ||
LLS addresses may be configured for 5 LLS sensors. If at least one LLS sensor is connected to FMB125 when configuring device using configurator, LLS sensor ID will be entered automatically. | |||
[[Image:Fmb125_lls_sensors.png|300px|right]] | |||
LLS addresses may be configured for 5 LLS sensors. If at least one LLS sensor is connected to FMB125 when configuring device using configurator, LLS sensor ID will be entered automatically.<br> | |||
Up to 16 LLS sensors are supported with <b>03.28.XX</b> firmware version | |||
Up to 8 passenger counter sensors "PP-01" can be connected each requiring 2 LLS addresses. The passenger counter sensor "PP-01" provides the possibility to count passengers getting either on or off public transport (bus, trolleybus, etc.). | |||
[[Category:FMB125 Configuration]] | |||