TEST-X: Difference between revisions
Appearance
No edit summary |
No edit summary |
||
| Line 8: | Line 8: | ||
<tr> | <tr> | ||
<td style="vertical-align: middle; text-align: center;"> | <td style="vertical-align: middle; text-align: center;"> Auto geofence </td> | ||
<td style="vertical-align: middle; text-align: center;"> | <td style="vertical-align: middle; text-align: center;"> 1017500 </td> | ||
<td style="vertical-align: middle; text-align: center;"> Disables, or enables and sets priority | <td style="vertical-align: middle; text-align: center;"> Disables, or enables and sets priority for record generation. </td> | ||
<td style="vertical-align: middle; text-align: left;"> | <td style="vertical-align: middle; text-align: left;"> ''0''' = Disable Disable scenario. | ||
'''1 | '''1''' = Low priority Device makes an additional record with indication of event cause. | ||
'''2''' = High priority Device makes an additional record with high priority flag and immediately sends an event packet to the server by GPRS. </td> | |||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td style="vertical-align: middle; text-align: center;"> | <td style="vertical-align: middle; text-align: center;"> Generate event </td> | ||
<td style="vertical-align: middle; text-align: center;"> | <td style="vertical-align: middle; text-align: center;"> 20001 </td> | ||
<td style="vertical-align: middle; text-align: center;"> | <td style="vertical-align: middle; text-align: center;"> Defines when the event will be generated </td> | ||
<td style="vertical-align: middle; text-align: left;"> '''0 =''' | <td style="vertical-align: middle; text-align: left;"> '''0 =''' On exit <br> | ||
'''1 =''' | '''1 =''' On enter <br> | ||
'''2 =''' On both <br> | |||
</td> | </td> | ||
| Line 26: | Line 29: | ||
<tr> | <tr> | ||
<td style="vertical-align: middle; text-align: center;"> | <td style="vertical-align: middle; text-align: center;"> Activation timeout (s) </td> | ||
<td style="vertical-align: middle; text-align: center;"> | <td style="vertical-align: middle; text-align: center;"> 20002 </td> | ||
<td style="vertical-align: middle; text-align: center;"> Sets the | <td style="vertical-align: middle; text-align: center;"> Sets the duration in seconds for two conditions: <br> | ||
<td style="vertical-align: middle; text-align: left;"> Minimum value '''= | 1. '''In Wait State:''' how long the vehicle must be stationary with a GNSS fix before the geofence is armed. <br> | ||
2. '''In Active State:''' how long the vehicle must be moving without a GNSS fix to trigger an alarm. | |||
</td> | |||
<td style="vertical-align: middle; text-align: left;"> Minimum value '''= 0''' <br> | |||
Maximum value '''= 65535''' </td> | Maximum value '''= 65535''' </td> | ||
| Line 35: | Line 41: | ||
<tr> | <tr> | ||
<td style="vertical-align: middle; text-align: center;"> | <td style="vertical-align: middle; text-align: center;"> Radius (m) </td> | ||
<td style="vertical-align: middle; text-align: center;"> | <td style="vertical-align: middle; text-align: center;"> 20003 </td> | ||
<td style="vertical-align: middle; text-align: center;"> | <td style="vertical-align: middle; text-align: center;"> Sets the radius of the circular geofence in meters, measured from the vehicle's position when armed. </td> | ||
<td style="vertical-align: middle; text-align: left;"> '''0''' | <td style="vertical-align: middle; text-align: left;"> inimum value '''= 0''' <br> | ||
''' | Maximum value '''= 1000000''' </td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td style="vertical-align: middle; text-align: center;"> | <td style="vertical-align: middle; text-align: center;"> Deactivate by </td> | ||
<td style="vertical-align: middle; text-align: center;"> | <td style="vertical-align: middle; text-align: center;"> 20004 </td> | ||
<td style="vertical-align: middle; text-align: center;"> | <td style="vertical-align: middle; text-align: center;"> Selects the source that will deactivate an armed geofence and return the system to the Wait State. </td> | ||
<td style="vertical-align: middle; text-align: left;"> | <td style="vertical-align: middle; text-align: left;"> 0 - Power Voltage: Deactivates if external voltage exceeds a predefined threshold. | ||
'''1 = Digital Input 1:''' Deactivates if DIN1 becomes active. <br> | |||
'''2 = Digital Input 2:''' Deactivates if DIN2 becomes active. <br> | |||
'''3 = Digital Input 3:''' Deactivates if DIN3 becomes active. <br> | |||
'''4 = iButton:''' Deactivates if an authorized iButton is presented. | |||
</td> | |||
''' | |||
''' | |||
</tr> | </tr> | ||
</table> | </table> | ||
Revision as of 15:33, 11 September 2025
| PARAMETER NAME | PARAMETER ID (RELATED AVL ID) | DESCRIPTION | VALUES |
|---|---|---|---|
| Auto geofence | 1017500 | Disables, or enables and sets priority for record generation. | 0' = Disable Disable scenario.
1 = Low priority Device makes an additional record with indication of event cause. 2 = High priority Device makes an additional record with high priority flag and immediately sends an event packet to the server by GPRS. |
| Generate event | 20001 | Defines when the event will be generated | 0 = On exit 1 = On enter |
| Activation timeout (s) | 20002 | Sets the duration in seconds for two conditions: 1. In Wait State: how long the vehicle must be stationary with a GNSS fix before the geofence is armed. |
Minimum value = 0 Maximum value = 65535 |
| Radius (m) | 20003 | Sets the radius of the circular geofence in meters, measured from the vehicle's position when armed. | inimum value = 0 Maximum value = 1000000 |
| Deactivate by | 20004 | Selects the source that will deactivate an armed geofence and return the system to the Wait State. | 0 - Power Voltage: Deactivates if external voltage exceeds a predefined threshold.
1 = Digital Input 1: Deactivates if DIN1 becomes active. |