Difference between revisions of "FMB630 Accessories"

From Wiki Knowledge Base | Teltonika GPS
(Created page with "{{Template:FMB640_Accessories|model=FMB630|pic_ds1820=400px|center}}")
 
Line 1: Line 1:
{{Template:FMB640_Accessories|model=FMB630|pic_ds1820=[[Image:FMB640_DS1820.png|400px|center]]}}
+
{{Template:FMB640_Accessories|model=FMB630||fuel_sensor=x|panic_button=x|inv_relay=x|imb_relay=x|pic_relay=x|DS1820=x|DS1990A=x|impulse_meter=x}}

Revision as of 08:50, 31 May 2018

Main Page > EOL Products > FMB630 > FMB630 Manual > FMB630 Accessories
Bw nb.png Please order accessories separately as they are not included into device package.


Accessory and its description Accessory connection schematic
Fuel tank sensors Fuel sensor connection to FMB630
A fuel tank level sensor which indicates the approximate fuel level on the driver's indicator panel exists in most cars. If the sensor returns analogue signal proportional to fuel level it can be connected to FMB630 Analog input. After connection to the tank fuel level sensor a calibration is needed because most fuel tank sensors are not linear. Calibration is performed by measuring voltage values resulting from the volume of fuel in tank.
Alarm buttons, door sensors etc. Panic button connection to FMB630
Alarm buttons, door sensors, ignition, etc. have two output states: high or low. FMB630 Digital inputs are used to detect these states.
Relays Inverting relay connection to FMB630
In cases when sensor output signal is negative, an additional relay has to be installed to convert negative signal to positive.
Immobilizer relay Immobilizer relay connection to FMB630 output
When connected as shown on the right hand side, FMB630 disables engine starter when output is ON.
Automotive relay Automotive relay pinout
An ordinary automotive relay is used to invert input signal or to immobilize engine starter. Note that relays can be 12 V or 24 V capable.
Sch ord relay.png
1-Wire devices Digital thermometer DS1820 and TTJ100 connection to FMB630
One of the implemented features on FMB630 is 1-Wire® data protocol, which enables connection to devices such as thermometer (DS1820, DS18S20 and DS18B20) and I-Button DS1990A.
TTJ sensor pinout
FMB640 TTJ.png
I-Button DS1990A connection to FMB630
Impulse counters Pulse fuel meters connection scheme
Here two pulse meters are used, where one is mounted on the direct flow valve and the other on the return flow valve. Data from both meters is sent to the FMB630. Then FMB630 calculates DIN3-DIN4. Resulting difference equals to fuel consumption. Filter should be used on the direct flow pipe to prevent any damage caused by impurities in the liquid. The filter mounted in the meter inlet is only a safety filter and it is too small to act as a strainer. Read more about impulse counters here