Difference between revisions of "Template:FM36YX I/O settings"

From Wiki Knowledge Base | Teltonika GPS
Line 92: Line 92:
 
| style="text-align: left; vertical-align: center;" | Area Code
 
| style="text-align: left; vertical-align: center;" | Area Code
 
| style="text-align: left; vertical-align: top;" | Location Area code (LAC), it depends on GSM operator.<br />It provides unique number which assigned to a set of base GSM stations.<br />Max value: 65536
 
| style="text-align: left; vertical-align: top;" | Location Area code (LAC), it depends on GSM operator.<br />It provides unique number which assigned to a set of base GSM stations.<br />Max value: 65536
 +
|-
 +
! style="text-align: left; vertical-align: top;" | 21
 +
| style="text-align: left; vertical-align: top;" | Dallas Temperature 1
 +
| style="text-align: left; vertical-align: top;" | 10 * Degrees (°C), -55 - +115, if 3000 – Dallas error
 +
|-
 +
! style="text-align: left; vertical-align: top;" | 22
 +
| style="text-align: left; vertical-align: top;" | Dallas Temperature 2
 +
| style="text-align: left; vertical-align: top;" | 10 * Degrees (°C), -55 - +115, if 3000 – Dallas error
 +
|-
 +
! style="text-align: left; vertical-align: top;" | 23
 +
| style="text-align: left; vertical-align: top;" | Dallas Temperature 3
 +
| style="text-align: left; vertical-align: top;" | 10 * Degrees (°C), -55 - +115, if 3000 – Dallas error
 +
|-
 +
! style="text-align: left; vertical-align: top;" | 24
 +
| style="text-align: left; vertical-align: top;" | Battery Voltage
 +
| style="text-align: left; vertical-align: top;" | Voltage: mV
 +
|-
 +
! style="text-align: left; vertical-align: top;" | 25
 +
| style="text-align: left; vertical-align: top;" | Battery Charging Current
 +
| style="text-align: left; vertical-align: top;" | Current: mA
 +
|-
 +
! style="text-align: left; vertical-align: top;" | 26
 +
| style="text-align: left; vertical-align: top;" | Ignition
 +
| style="text-align: left; vertical-align: top;" | Ignition status indication. Logic: 0 / 1
 +
|-
 +
! style="text-align: left; vertical-align: top;" | 27
 +
| style="text-align: left; vertical-align: top;" | Network Type
 +
| style="text-align: left; vertical-align: top;" | 0 – 3G network, 1 – 2G network
 +
|-
 +
! style="text-align: left; vertical-align: top;" | 28
 +
| style="text-align: left; vertical-align: top;" | Continuous Odometer
 +
| style="text-align: left; vertical-align: top;" | Distance which device has been traveled with ignition ON: m
 +
|-
 +
! style="text-align: left; vertical-align: top;" | 29
 +
| style="text-align: left; vertical-align: top;" | Dallas temperature ID1
 +
| style="text-align: left; vertical-align: top;" | 1st connected dallas temperature sensor ID
 +
|-
 +
! style="text-align: left; vertical-align: top;" | 30
 +
| style="text-align: left; vertical-align: top;" | Dallas temperature ID2
 +
| style="text-align: left; vertical-align: top;" | 2nd connected dallas temperature sensor ID
 +
|-
 +
! style="text-align: left; vertical-align: top;" | 31
 +
| style="text-align: left; vertical-align: top;" | Dallas temperature ID3
 +
| style="text-align: left; vertical-align: top;" | 3rd connected dallas temperature sensor ID
 +
|-
 +
! style="width: 200px; background: black; color: white;" colspan="3" | Eventual I/O elements (generate and send record to server only if appropriate conditions are met)
 
|-
 
|-
 
|}
 
|}

Revision as of 08:18, 1 June 2018

When no I/O element is enabled, AVL packet comes with GNSS information only. After enabling I/O element(s) AVL packet along with GNSS information contains current value(s) of enabled I/O element.


Permanent I/O elements (are always sent to server if enabled)
No. Property Name Description
00 Digital Input Status 1 Logic: 0 / 1
01 Digital Input Status 2 Logic: 0 / 1
02 Digital Input Status 3 Logic: 0 / 1
03 Digital Input Status 4 Logic: 0 / 1
04 Analog Input 1 Voltage: mV, 0 – 30 V
05 Digital Output 1 Logic: 0 / 1
06 Digital Output 2 Logic: 0 / 1
07 GNSS PDOP Probability * 10; 0-500
08 GNSS HDOP Probability * 10; 0-500
09 External Voltage Voltage: mV, 0 – 30 V
10 GNSS Power States:
0 – off state (when GPS module is off)
1 – Reserved
2 – GPS ready (antenna is working, but with no GPS fix)
3 – GPS working (antenna is working and has GPS fix)
4 – GPS sleep (when device is in GPS sleep mode)
5 – Overcurrent (The only condition to get value 5, then antenna is damaged and short circuit)
11 Movement Sensor 0 – not moving, 1 – moving.
12 Odometer Value Distance between two records: m
13 GSM Operator Currently used GSM Operator code
14 Speed (Km/h) Value in km/h, 0 – xxx km/h
15 iButton ID iButton ID number
16 Mode 0 – home on stop, 1 – home on move, 2 – roaming on stop, 3 – roaming on move, 4 – unknown on stop, 5 – unknown on move
17 GSM Signal GSM signal level value in scale 1 – 5
18 Deep Sleep 0 – not deep sleep mode, 1 – deep sleep mode
19 Cell ID GSM base station ID
20 Area Code Location Area code (LAC), it depends on GSM operator.
It provides unique number which assigned to a set of base GSM stations.
Max value: 65536
21 Dallas Temperature 1 10 * Degrees (°C), -55 - +115, if 3000 – Dallas error
22 Dallas Temperature 2 10 * Degrees (°C), -55 - +115, if 3000 – Dallas error
23 Dallas Temperature 3 10 * Degrees (°C), -55 - +115, if 3000 – Dallas error
24 Battery Voltage Voltage: mV
25 Battery Charging Current Current: mA
26 Ignition Ignition status indication. Logic: 0 / 1
27 Network Type 0 – 3G network, 1 – 2G network
28 Continuous Odometer Distance which device has been traveled with ignition ON: m
29 Dallas temperature ID1 1st connected dallas temperature sensor ID
30 Dallas temperature ID2 2nd connected dallas temperature sensor ID
31 Dallas temperature ID3 3rd connected dallas temperature sensor ID
Eventual I/O elements (generate and send record to server only if appropriate conditions are met)


Monitoring

I/O monitoring starts after enabling I/O element and setting up I/O parameters as it is shown below:

FM36 monitoring.jpg

Event generating

Events happen when the value of enabled I/O intersects thresholds (enter, exit or on both) predefined by High and Low level thresholds. Table below defines all available values of I/O settings.

Setting Value
Priority low, high
High level maximum threshold
Low level minimum threshold
Generate event on interval enter, on interval exit, on both enter and exit
Average constant 1 – 232 (4 Bytes)


FM36 Hysteresis.jpg

Hysteresis

FM36 Hysteresis 2.jpg


I/O elements can generate events according to hysteresis algorithm. If I/O event operand “Hysteresis” is selected, events will be generated as it is shown in the illustration below (I/O speed is taken as I/O value example):


FM36 Hysteresis 3.jpg