Main Page > EOL Products > FM3612 > FM3612 Manual > FM36YX Device Family Parameter listParameters value types
S8 – Signed Char S8[n] – String of n Char U8 – Unsigned Char U16 – Unsigned Short S32 – Signed Integer U32 – Unsigned Integer U64 – Unsigned Long Long Integer
System parameters
| Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 1000 | U8 | 0 | 0 | 2 | 0 – Disabled | Sleep Settings |
| 1 – GPS Sleep | ||||||
| 2 – Deep Sleep | ||||||
| 200 | U8 | 1 | 1 | 3000 | - | Sleep Timeout |
| 1001 | U8 | 0 | 0 | 1 | 0 - 10V | Analog Input value range |
| 1 – 30V | ||||||
| 1002 | U8 | 1 | 0 | 3 | 0 - ignition | Stop Detection Source |
| 1 - Msensor | ||||||
| 2 - GPS | ||||||
| 3 - ignition + Msensor | ||||||
| 1003 | U8 | 0 | 0 | 1 | 0 - Disabled | Static Navigation |
| 1 – Enabled | ||||||
| 1004 | 0 | 0 | 2 | 0 – Power voltage | Ignition Source | |
| 1 – Digital input 1 | ||||||
| 2 – Msensor | ||||||
| 1005 | 30000 mV | 13000 mV | 30000 mV | High Voltage Level | ||
| 1006 | 13000 mV | 0 | 30000 mV | Low Voltage Level | ||
| 1008 | 0 | 0 | 1 | 0 - Manual | Ignition Detection | |
| 1 – Automatic | ||||||
| 1009 | U8 | 10 | 0 | 65535 | Ignition Detection Timeout | |
| 1007 | U8 | 60 | 0 | 65535 | GNSS FIX Timeout for Time Synchronization via NTP | |
| 201 | U8 | 0 | 0 | 1 | 0 - Disabled | Saving/Sending without time synchronization |
| 1 – Enabled | ||||||
| 202 | U8 | 0 | 0 | 2 | 0 – GNSS (all available) | Satellite System |
| 1 – GPS | ||||||
| 2 – GLONASS | ||||||
Records parameters
| Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 1010 | Uint8 | default | 0 | 1 | 0 – arranging data starting from newest | Sorting |
| 1 – arranging data starting from oldest | ||||||
| 1011 | Uint8 | 60 | 0 | 259200 | Seconds | Active Data Link Timeout |
| 1012 | Uint8 | 300 | 1 | 300 | Seconds | Server Response Timeout |
GSM parameters
GPRS
| Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 1240 | S8 | 1 | 0 | 1 | 0 – GPRS is not allowed | GPRS content activation |
| 1 – GPRS is allowed | ||||||
| 1242 | S8[32] | "" | Empty | 32 char string | string | APN Name |
| 1243 | S8[30] | "" | Empty | 30 char string | string | APN username |
| 1244 | S8[30] | "" | Empty | 30 char string | string | APN Password |
| 1245 | S8[16] | "" | Empty | 31 char string | string | Domain |
| 1246 | S8[16] | 0 | Empty | 65535 | number | Target Server Port |
| 1247 | U8 | 0 | 0 | 1 | 0 – TCP | Protocol |
| 1 – UDP | ||||||
| 1248 | U8 | 0 | 0 | 1 | 0 – work with all networks | Network Type |
| 1 – work with 2G network | ||||||
| 2 – work with 3G network | ||||||
| 3 – work with 4G network | ||||||
SMS
| Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| ID | Uint8 | default | min | max | 0 – value = 0 | Name |
| 1 – value = 1 | ||||||
| ID | Uint8 | default | min | max | Value | Name |
| 1252 | S8[5] | "" | Empty | 5 char string | string | SMS Login |
| 1253 | S8[5] | "" | Empty | 5 char string | string | SMS Password |
| 1254 | U8 | 0 | -720 | +840 | minutes | SMS Time Zone |
| 1250 | U8 | 0 | 0 | 1 | 0 – SMS use is not allowed | SMS data sending settings |
| 1 – SMS use is allowed | ||||||
| 1273 | For detail info | SMS Data send week time schedule | ||||
| 1260-1269 | S8[17] | "" | 0 digit | 16 digit | string | Authorized phone numbers |
| 5000-5009 | S8[17] | "" | 0 digit | 16 digit | string | SMS Event PreDefined Numbers |
Operator list
| Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 1271 | For detailed info | Operator list | ||||