Template:FM36 I/O parameters Parameters: Difference between revisions
Appearance
Simkunas.ma (talk | contribs) No edit summary |
Simkunas.ma (talk | contribs) No edit summary |
||
| Line 68: | Line 68: | ||
|- | |- | ||
|} | |} | ||
Other I/O property elements can be configured in same logic. All I/O element parameters are listed in the next table. | |||
{| class="wikitable" | {| class="wikitable" | ||
Revision as of 09:21, 4 June 2018
| Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 2000 | S8 | 1 | 0 | 3 | 0 – Disabled | I/O#1 Priority |
| 1 – Low | ||||||
| 2 – High | ||||||
| 3 – Panic | ||||||
| 2001 | S32 | 0 | -2147483647 | 2147483647 | I/O#1 High level | |
| 2002 | S32 | 0 | -2147483647 | 2147483647 | I/O#1 Low level | |
| 2003 | S8 | 3 | 0 | 5 | 0 – On Exit | I/O#1 event generation type |
| 1 – On Entrance | ||||||
| 2 – On Both | ||||||
| 3 – Monitoring | ||||||
| 4 – Hysteresis | ||||||
| 5 – On Change | ||||||
| 2004 | S32 | 10 | 0 | 2592000 | I/O#1 Low level | |
Other I/O property elements can be configured in same logic. All I/O element parameters are listed in the next table.
| I/O Element Number | I/O element parameters |
|---|---|
| Digital Input 1 | 2000-2004 |
| Digital Input 2 | 2010-2014 |