Difference between revisions of "Template:FM36 GSM Parameters"

From Wiki Knowledge Base | Teltonika GPS
Line 254: Line 254:
  
 
! style="text-align: center; vertical-align: center;" |1271
 
! style="text-align: center; vertical-align: center;" |1271
| style="text-align: center; vertical-align: center;" colspan=6 |[[FM36_Operator_list|For detailed info]]
+
| style="text-align: center; vertical-align: center;" colspan=5 |[[FM36_Operator_list|For detailed info]]
 
| style="text-align: center; vertical-align: center;" |Operator list
 
| style="text-align: center; vertical-align: center;" |Operator list
 
|-
 
|-

Revision as of 13:22, 4 June 2018

GPRS


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1240 S8 1 0 1 0 – GPRS is not allowed GPRS content activation
1 – GPRS is allowed
1242 S8[32] "" Empty 32 char string string APN Name
1243 S8[30] "" Empty 30 char string string APN username
1244 S8[30] "" Empty 30 char string string APN Password
1245 S8[16] "" Empty 31 char string string Domain
1246 S8[16] 0 Empty 65535 number Target Server Port
1247 U8 0 0 1 0 – TCP Protocol
1 – UDP
1248 U8 0 0 1 0 – work with both networks Use 2G only
1 – work only with 2G network

SMS



Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
ID Uint8 default min max 0 – value = 0 Name
1 – value = 1
ID Uint8 default min max Value Name
1252 S8[5] "" Empty 5 char string string SMS Login
1253 S8[5] "" Empty 5 char string string SMS Password
1254 U8 0 -720 +840 minutes SMS Time Zone
1250 U8 0 0 1 0 – SMS use is not allowed SMS data sending settings
1 – SMS use is allowed
1273 For detail info SMS Data send week time schedule
1260-1269 S8[17] "" 0 digit 16 digit string Authorized phone numbers
5000-5009 S8[17] "" 0 digit 16 digit string SMS Event PreDefined Numbers

SMS Events



Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
ID Uint8 default min max 0 – value = 0 Name
1 – value = 1
ID Uint8 default min max Value Name

Operator list



Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1271 For detailed info Operator list