Template:FMA Device Family Features Parameter list: Difference between revisions
No edit summary |
|||
Line 226: | Line 226: | ||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Parameter ID''' | ! style="width: 150px; background: black; color: white;" rowspan=2 |'''Parameter ID''' | ||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Parameter Type''' | ! style="width: 150px; background: black; color: white;" rowspan=2 |'''Parameter Type''' | ||
! style="width: 150px; background: black; color: white;" rowspan=2 |''' | ! style="width: 150px; background: black; color: white;" rowspan=2 |'''Recommended value''' | ||
! style="width: 150px; background: black; color: white;" colspan=2 |'''Value range''' | ! style="width: 150px; background: black; color: white;" colspan=2 |'''Value range''' | ||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Value''' | ! style="width: 150px; background: black; color: white;" rowspan=2 |'''Value''' |
Revision as of 10:31, 22 August 2018
Green driving parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1890 | Uint8 | - | 0 | 1 | 0 – Disable | Scenario settings |
1 – Enable | ||||||
1891 | Uint8 | - | 0 | 2 | 0 - disable | Digital Output Control |
1 - DOUT1 | ||||||
2 - DOUT2 | ||||||
1909 | Uint8 | - | 0 | 1 | 0 - GPS | Source |
1 - Accelerometer | ||||||
1892 | Float | 0.25 | 0.25 | 0.85 | mG | Max Acceleration Force |
1893 | Float | 0.35 | 0.25 | 0.85 | mG | Max Braking Force |
1894 | Float | 0.2 | 0.1 | 1.0 | mG | Max Cornering Force |
Overspeeding scenario parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1895 | Uint8 | 0 | 0 | 1 | 0 – Disable | Scenario settings |
1 – Enable | ||||||
1896 | Uint8 | - | 0 | 2 | 0 – None | Digital Output control |
1 – DOUT 1 | ||||||
2 – DOUT 2 | ||||||
1897 | Uint16 | - | 0 | 260 | km/h | Max speed |
Jamming scenario parameters
Parameter ID | Parameter Type | Recommended Value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1898 | Uint8 | - | 0 | 1 | 0 – Disable | Scenario settings |
1 – Enable | ||||||
1899 | Uint8 | - | 0 | 2 | 0 – None | Digital Output control |
1 – DOUT1 | ||||||
2 – DOUT2 | ||||||
1900 | Uint8 | - | 0 | 2 | 0 – Low sensitivity (50 RSSI) | Jamming sensitivity |
1 – Medium sensitivity (30 RSSI) | ||||||
2 – High sensitivity (10 RSSI) | ||||||
1901 | Uint16 | 60 | 0 | 65535 | Seconds | Jamming Timeout |
1902 | Uint16 | 0 | 0 | 65535 | Seconds | Jamming Pulse Duration |
Immobilizer scenario parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1903 | Uint8 | - | 0 | 1 | 0 – Disable | Scenario settings |
1 – Enable | ||||||
1904 | Uint8 | - | 0 | 2 | 0 – Disable | Digital Output Control |
1 – DOUT1 | ||||||
2 – DOUT2 |
iButton read notification
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
11704 | Uint8_t | 0 | 0 | 1 | 0 - Disabled | DOUT control |
1 - Enabled | ||||||
11705 | Uint16_t | 200 | 100 | 50000 | Milliseconds | DOUT duration |
11706 | Uint8_t | 0 | 0 | 1 | 0 - Disabled | iButton notification list |
1 - Enabled | ||||||
11707 | Uint8_t | 0 | 0 | 1 | 0 - Disabled | Depend on ignition |
1 - Enabled |
Trip scenario parameters
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
11800 | Uint8 | 0 | 0 | 3 | 0 – Disable | Scenario settings |
1 – Low priority | ||||||
2 – High priority | ||||||
3 – Panic priority | ||||||
11801 | Uint8 | 1 | 0 | 1 | 0 – Disable | Eventual records |
1 – Enable | ||||||
11802 | Uint8 | 0 | 0 | 1 | 0 – Continuous | Mode |
1 – Between records | ||||||
11803 | Uint8 | 5 | 0 | 255 | km/h | Start speed |
11804 | Uint16 | 60 | 0 | 65535 | Seconds | Ignition off timeout |
7031 | Uint8 | 0 | 0 | 10 | Phone number | Send SMS to |
8031 | String | "Trip" | 0 | 160 | Text | Sms text |
DOUT control via call scenario parameters
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
12000 | Uint8 | 0 | 0 | 2 (1 for FMB125) | 0 – None | Digital Output control |
1 – DOUT 1 | ||||||
2 – DOUT 2 | ||||||
12001 | Uint8 | 0 | 0 | 3 (1 for FMB125) | 0 – None | DOUT deactivation |
1 – DIN 1 | ||||||
2 – DIN 2 | ||||||
3 – DIN 3 | ||||||
12002 | Int32 | 5 | 0 | 2147483647 | Seconds | Duration timeout |