Line 270: |
Line 270: |
| | style="text-align: center; vertical-align: center;" |1 – Enable | | | style="text-align: center; vertical-align: center;" |1 – Enable |
| |- | | |- |
− | ! style="text-align: center; vertical-align: center;" |1142 | + | ! style="text-align: center; vertical-align: center;" |1242 |
| | style="text-align: center; vertical-align: center;" |Char | | | style="text-align: center; vertical-align: center;" |Char |
| | style="text-align: center; vertical-align: center;" |- | | | style="text-align: center; vertical-align: center;" |- |
Line 437: |
Line 437: |
| |- | | |- |
| |} | | |} |
| + | |
| ==Data Acquisition Modes parameters== | | ==Data Acquisition Modes parameters== |
| ===Home Network GSM operator code "Vehicle on STOP" parameters=== | | ===Home Network GSM operator code "Vehicle on STOP" parameters=== |
Revision as of 12:08, 22 July 2019
System parameters
Parameter ID
|
Parameter Type
|
Recomended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1002
|
Uint8
|
-
|
0
|
2
|
0 – Ignition
|
Stop Detection Source
|
1 – Movement sensor
|
2 – GPS
|
1003
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Static navigation
|
1 – Enable
|
1004
|
Uint8
|
-
|
0
|
2
|
0 – Power voltage
|
Ignition source
|
1 – Digital input 1
|
1 – Movement
|
1005
|
Uint16
|
-
|
0
|
30000
|
Voltage
|
Power Voltage High Level
|
1006
|
Uint16
|
-
|
0
|
30000
|
Voltage
|
Power Voltage Low Level
|
1920
|
Uint8
|
-
|
0
|
1
|
0 – Manual
|
Ignition detection (Power voltage)
|
1 – Auto
|
1921
|
Uint8
|
10
|
0
|
65536
|
Seconds
|
Ignition detection timeout
|
201
|
Uint8
|
1
|
0
|
2
|
0 – after position fix
|
Records Saving/Sending
|
1 – always
|
2 – after time sync
|
202
|
Uint8
|
0
|
0
|
2
|
0 – GNSS (all available)
|
GNSS System
|
1 – GPS only
|
2 – GLONASS only
|
1007
|
Uint32
|
-
|
1
|
259200
|
Seconds
|
GNSS Fix Timeout
|
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1000
|
Uint8
|
-
|
0
|
2
|
0 – Disable
|
Sleep settings
|
1 – Sleep
|
2 – Deep sleep
|
200
|
Uint8
|
-
|
1
|
3000
|
Minutes
|
Timeout
|
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1001
|
Uint8
|
-
|
0
|
1
|
0 – 0...10V
|
Analog Input value range
|
1 – 1...30V
|
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1008
|
Uint8
|
1
|
0
|
1
|
0 - disabled
|
NTP Time Synchronization
|
1 – enabled
|
Records parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1010
|
Uint8
|
-
|
0
|
1
|
0 - From oldest
|
Sorting
|
1 - From Newest
|
1011
|
Uint32
|
-
|
0
|
259200
|
Seconds
|
Active Data Link Timeout
|
1012
|
Uint8
|
-
|
0
|
300
|
Seconds
|
Server Response Timeout
|
|
ATTENTION! Some GSM operators may disconnect the device from an active data link if the device doesn’t send any data for a very long time, even if active data link timeout is set to maximum value. The amount of time that an operator keeps the link open depends solely on the operator. For example, if active data link timeout is set to maximum, 259200 seconds (72 hours), and the device sends data to server every 86400 seconds (24 hours), the operator might disconnect the link earlier and the device will have to connect to the server anew. This may cost extra, depending on the operator GPRS data charge. It is strongly recommended, when using active data link timeout, that data sending to the server should not be very rare (24 hours or more). If data sending is more frequent, then the operator will not disconnect the device form the server.
|
GSM parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1240
|
Uint8
|
-
|
0
|
1
|
0 – Disable
|
GPRS content activation
|
1 – Enable
|
1242
|
Char
|
-
|
0
|
32
|
String
|
APN name
|
1243
|
Char
|
-
|
0
|
30
|
String
|
APN username
|
1244
|
Char
|
-
|
0
|
30
|
String
|
APN password
|
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1245
|
Char
|
-
|
0
|
31
|
String
|
Domain
|
1246
|
Uint16
|
-
|
0
|
65535
|
Number
|
Target Server Port
|
1247
|
Uint8
|
-
|
0
|
1
|
0 – TCP
|
Protocol
|
1 – UDP
|
1248
|
Uint8
|
-
|
0
|
1
|
0 – Not Allowed
|
Always online
|
1 – Allowed
|
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1252
|
Char
|
-
|
0
|
5
|
String
|
SMS Login
|
1253
|
Char
|
-
|
0
|
5
|
String
|
SMS password
|
1250
|
Char
|
-
|
0
|
1
|
0 - Not Allowed
|
SMS data sending settings
|
1 - Allowed
|
1273
|
Uint32
|
Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF
|
-
|
-
|
Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday.
|
GPRS Week Time
|
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1260-1269
|
Char
|
-
|
1 digit
|
16 digits
|
String
|
Authorized phone numbers
|
150-159
|
Char
|
-
|
1 digit
|
16 digits
|
String
|
SMS Event PreDefined Numbers
|
1271 X
|
u32
|
X defines starting position that is changed: If X is from 0 to 49, X means index of operator code which has to be configured.
|
0 digit
|
7 digits
|
String
|
Operator list
|
1272 X
|
u32
|
X defines starting position that is changed: If X is from 0 to 49, X means index of operator code which has to be configured.
|
0 digit
|
7 digits
|
String
|
Operator Black list
|
Data Acquisition Modes parameters
Home Network GSM operator code "Vehicle on STOP" parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1540
|
Uint32
|
-
|
0
|
2592000
|
Seconds
|
Min Period
|
1543
|
Uint8
|
1
|
1
|
225
|
Records
|
Min Saved Records
|
1544
|
Uint32
|
-
|
0
|
2592000
|
Seconds
|
Send period
|
1545
|
Uint32
|
Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF
|
-
|
-
|
Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday.
|
GPRS Week Time
|
Home Network GSM operator code "Vehicle on MOVING" parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1550
|
Uint32
|
-
|
0
|
2592000
|
Seconds
|
Min Period
|
1551
|
Uint32
|
-
|
0
|
65535
|
Meters
|
Min distance
|
1552
|
Uint16
|
0
|
1
|
160
|
Angle
|
Min angle
|
1553
|
Uint16
|
1
|
1
|
255
|
Records
|
Min Saved Records
|
1544
|
Uint32
|
-
|
0
|
2592000
|
Seconds
|
Send period
|
1555
|
Uint32
|
Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF
|
-
|
-
|
Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday.
|
GPRS Week Time
|
1556
|
Uint16
|
-
|
0
|
255
|
km/h
|
Min Speed
|
1557
|
Uint8
|
-
|
0
|
1
|
0- GPS
|
Min Speed Source
|
1- LVCAN
|
Roaming Network GSM operator code "Vehicle on STOP" parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1560
|
Uint32
|
-
|
0
|
2592000
|
Seconds
|
Min Period
|
1563
|
Uint8
|
1
|
1
|
225
|
Records
|
Min Saved Records
|
1564
|
Uint32
|
-
|
0
|
2592000
|
Seconds
|
Send period
|
1565
|
Uint32
|
Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF
|
-
|
-
|
Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday.
|
GPRS Week Time
|
Roaming Network GSM operator code "Vehicle on MOVING" parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1570
|
Uint32
|
-
|
0
|
2592000
|
Seconds
|
Min Period
|
1571
|
Uint32
|
-
|
0
|
65535
|
Meters
|
Min distance
|
1572
|
Uint16
|
0
|
1
|
160
|
Angle
|
Min angle
|
1573
|
Uint16
|
1
|
1
|
255
|
Records
|
Min Saved Records
|
1574
|
Uint32
|
-
|
0
|
2592000
|
Seconds
|
Send period
|
1575
|
Uint32
|
Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF
|
-
|
-
|
Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday.
|
GPRS Week Time
|
1576
|
Uint16
|
-
|
0
|
255
|
km/h
|
Min Speed
|
1577
|
Uint8
|
-
|
0
|
1
|
0- GPS
|
Min Speed Source
|
1- LVCAN
|
Unknown Network GSM operator code "Vehicle on STOP" parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1580
|
Uint32
|
-
|
0
|
2592000
|
Seconds
|
Min Period
|
1583
|
Uint8
|
1
|
1
|
225
|
Records
|
Min Saved Records
|
1584
|
Uint32
|
-
|
0
|
2592000
|
Seconds
|
Send period
|
1585
|
Uint32
|
Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF
|
-
|
-
|
Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday.
|
GPRS Week Time
|
Unknown Network GSM operator code "Vehicle on MOVING" parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1590
|
Uint32
|
-
|
0
|
2592000
|
Seconds
|
Min Period
|
1591
|
Uint32
|
-
|
0
|
65535
|
Meters
|
Min distance
|
1592
|
Uint16
|
0
|
1
|
160
|
Angle
|
Min angle
|
1593
|
Uint16
|
1
|
1
|
255
|
Records
|
Min Saved Records
|
1594
|
Uint32
|
-
|
0
|
2592000
|
Seconds
|
Send period
|
1595
|
Uint32
|
Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF
|
-
|
-
|
Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday.
|
GPRS Week Time
|
1596
|
Uint16
|
-
|
0
|
255
|
km/h
|
Min Speed
|
1597
|
Uint8
|
-
|
0
|
1
|
0- GPS
|
Min Speed Source
|
1- LVCAN
|
Features parameters
Green driving parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1890
|
Uint8
|
-
|
0
|
1
|
0 – Disable
|
Scenario settings
|
1 – Enable
|
1891
|
Uint8
|
-
|
0
|
2
|
0 - disable
|
Digital Output Control
|
1 - DOUT1
|
2 - DOUT2
|
1909
|
Uint8
|
-
|
0
|
1
|
0 - GPS
|
Source
|
1 - Accelerometer
|
1892
|
Float
|
0.25
|
0.25
|
0.85
|
mG
|
Max Acceleration Force
|
1893
|
Float
|
0.35
|
0.25
|
0.85
|
mG
|
Max Braking Force
|
1894
|
Float
|
0.2
|
0.1
|
1.0
|
mG
|
Max Cornering Force
|
Overspeeding scenario parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1895
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Scenario settings
|
1 – Enable
|
1896
|
Uint8
|
-
|
0
|
2
|
0 – None
|
Digital Output control
|
1 – DOUT 1
|
2 – DOUT 2
|
1897
|
Uint16
|
-
|
0
|
260
|
km/h
|
Max speed
|
Jamming scenario parameters
Parameter ID
|
Parameter Type
|
Recommended Value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1898
|
Uint8
|
-
|
0
|
1
|
0 – Disable
|
Scenario settings
|
1 – Enable
|
1899
|
Uint8
|
-
|
0
|
2
|
0 – None
|
Digital Output control
|
1 – DOUT1
|
2 – DOUT2
|
1900
|
Uint8
|
-
|
0
|
2
|
0 – Low sensitivity (50 RSSI)
|
Jamming sensitivity
|
1 – Medium sensitivity (30 RSSI)
|
2 – High sensitivity (10 RSSI)
|
1901
|
Uint16
|
60
|
0
|
65535
|
Seconds
|
Jamming Timeout
|
1902
|
Uint16
|
0
|
0
|
65535
|
Seconds
|
Jamming Pulse Duration
|
Immobilizer scenario parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1903
|
Uint8
|
-
|
0
|
1
|
0 – Disable
|
Scenario settings
|
1 – Enable
|
1904
|
Uint8
|
-
|
0
|
2
|
0 – Disable
|
Digital Output Control
|
1 – DOUT1
|
2 – DOUT2
|
1905
|
Uint8
|
-
|
0
|
1
|
0 – Disable
|
iButton list checking
|
1 – Enable
|
1906
|
Uint16
|
30
|
5
|
65353
|
Seconds
|
Ignition Off Timeout
|
iButton read notification
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1907
|
Uint8
|
-
|
0
|
1
|
0 - Disabled
|
iButton detect
|
1 - Enabled
|
1908
|
Uint8_t
|
0
|
0
|
1
|
0 - Disabled
|
Digital Output Control
|
1 - DOUT1
|
2 - DOUT2
|
Trip scenario parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1280
|
Uint8
|
-
|
0
|
1
|
0 – Disable
|
Scenario settings
|
1 – Enable
|
1281
|
Uint8
|
-
|
0
|
255
|
km/h
|
Start speed
|
1282
|
Uint16
|
-
|
0
|
65535
|
Seconds
|
Ignition off timeout
|
1283
|
Uint8
|
-
|
0
|
1
|
0 – Not
|
Continuous distance counting
|
1 – Continuous
|
1284
|
Uint8
|
-
|
0
|
1
|
0 – Disable
|
Remember iButton ID
|
1 – Enable
|
1285
|
Uint8
|
-
|
0
|
-
|
Meters
|
Odometer Value
|
AutoGeofencing scenario parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1101
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Scenario Settings
|
1 – Enable
|
1102
|
Uint16
|
60
|
0
|
65535
|
0 – Disable
|
Activation Timeout
|
1100
|
Uint8
|
-
|
0
|
1
|
0 – Ignition
|
Deactivation Source
|
1 – Enable
|
1103
|
Uint8
|
1
|
0
|
1
|
0 - Low
|
AutoGeofence event priority
|
1 - hight
|
1104
|
Uint8
|
2
|
0
|
3
|
0 - No Event
|
AutoGeofence event generating
|
1 - On entering zone
|
2 - On exiting zone
|
3 - On both
|
1105
|
Uint32
|
100
|
0
|
1000000
|
Meters
|
Radius
|
iButton list
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3500-3999
|
Uint64
|
-
|
0
|
FFFFFFFF FFFFFFFF
|
0 – iButton ID
|
iButton list
|
Manual Geofence
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1020
|
Uint32
|
1000
|
0
|
1000000
|
Border value meters
|
Frame border
|
1030
|
Uint8
|
-
|
0
|
1
|
0 - Circle
|
Shape type
|
1 - Rectangle
|
1031
|
Uint8
|
-
|
0
|
2
|
0 – Low
|
Priority
|
1 – High
|
2 – Panic
|
1032
|
Uint8
|
-
|
0
|
3
|
0 - No event
|
Generate event
|
1 - On entering zone
|
2 - On exiting zone
|
3 - On both
|
1033
|
float
|
-
|
-180
|
180
|
Rectangle left down corner X coordinate
|
Longitude X1
|
Or X1 Coordinate circle middle point
|
1034
|
float
|
-
|
-90
|
90
|
Rectangle left down corner Y1 coordinate
|
latitude Y1
|
Or Y1 Coordinate circle middle point
|
1035
|
float
|
-
|
-180
|
180
|
Rectangle right upper corner X2 coordinate
|
longitude X2
|
1035
|
float
|
1000
|
0
|
1000000
|
X2 coordinate radius of circle
|
longitude X2
|
1036
|
float
|
-
|
-90
|
90
|
Rectangle right upper corner Y2 coordinate
|
latitude Y2
|
If circle ID 1036 is not used
|
Similarly to a group defined in the upper table:
Zone number
|
Parameter
|
Shape
|
Priority
|
Generate event
|
X1
|
Y1
|
X2
|
Radius
|
Y2
|
1 |
1030 |
1031 |
1032 |
1033 |
1034 |
1035 |
1035 |
1036
|
2 |
1040 |
1041 |
1042 |
1043 |
1044 |
1045 |
1045 |
1046
|
3 |
1050 |
1051 |
1052 |
1053 |
1054 |
1055 |
1055 |
1056
|
4 |
1060 |
1061 |
1062 |
1063 |
1064 |
1065 |
1065 |
1066
|
5 |
1070 |
1071 |
1072 |
1073 |
1074 |
1075 |
1075 |
1076
|
Parameters
ID
|
Parameter name
|
Value type
|
Value description
|
Min Value
|
max Value
|
1300
|
I/O#1 property parameter
|
S8
|
0 - disable
|
0
|
1
|
1 - enable
|
1301
|
I/O#1 priority parameter
|
S8
|
0 - Low
|
0
|
2
|
1 - High
|
2 - Panic
|
1302
|
I/O#1 High level
|
S32
|
used to set thresholds for I/O properties to generate events.
|
-2147483647
|
2147483647
|
1303
|
I/O#1 Low level
|
S32
|
used to set thresholds for I/O properties to generate events.
|
-2147483647
|
2147483647
|
1304
|
I/O#1 logic operand
|
S8
|
0 - on range exit
|
0
|
5
|
1 - on range entrance
|
2 - both
|
3 - monitoring
|
4 - hysteresis
|
5 - on changes
|
1305
|
I/O#1 averaging length
|
S32
|
Parameter defines I/O property sample length to average
|
0
|
2592000
|
Similarly to a group defined in the upper table
I/O parameters
I/O Element Number
|
I/O element parameters
|
Digital Input 1
|
1300-1305
|
Digital Input 2
|
1310-1315
|
Digital Input 3
|
1320-1325
|
Analog Input 1
|
1330-1335
|
Digital Output 1
|
1340-1345
|
Digital Output 2
|
1350-1355
|
GNSS PDOP
|
1360-1365
|
GNSS HDOP
|
1370-1375
|
External Voltage
|
1380-1385
|
GNSS Power
|
1390-1395
|
Movement Sensor
|
1400-1405
|
Trip distance
|
1410-1415
|
GSM Operator
|
1420-1425
|
Speed (Km/h)
|
1430-1435
|
iButton ID
|
1440-1445
|
Mode
|
1450-1455
|
GSM Signal
|
1460-1465
|
Deep Sleep
|
1470-1475
|
Cell ID
|
1480-1485
|
Area Code
|
1490-1495
|
Dallas Temperature 1
|
1500-1505
|
Reserved
|
1510-1515
|
Reserved
|
1520-1525
|
Battery Voltage
|
1530-1535
|
Battery Charging Current
|
1110-1115
|
Ignition
|
1120-1125
|
Total Distance
|
1130-1135
|
Reserved IO1
|
1140-1145
|
Reserved IO2
|
1150-1155
|
RFID
|
1160-1165
|
LLS Fuel1
|
1720- 1725
|
LLS Temp1
|
1730- 1735
|
LLS Fuel2
|
1740- 1745
|
LLS Temp2
|
1750- 1755
|
LLS Fuel3
|
1760- 1765
|
LLS Temp3
|
1770- 1775
|
LLS Fuel4
|
1780- 1785
|
LLS Temp4
|
1790- 1795
|
LLS Fuel5
|
1800- 1805
|
LLS Temp5
|
1810- 1815
|
Dallas Temperature 2
|
1820- 1825
|
Dallas Temperature 3
|
1830- 1835
|
Dallas Temperature 4
|
1840- 1845
|
Dallas Temperature ID 1
|
1850- 1855
|
Dallas Temperature ID 2
|
1860- 1865
|
Dallas Temperature ID 3
|
1870- 1875
|
Dallas Temperature ID 4
|
1880- 1885
|
LVCAN
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1600
|
Uint8
|
0
|
0
|
2
|
0 – Auto detect
|
LVCAN Mode
|
1 – LV-CAN200
|
2 – ALL-CAN300
|
1601
|
Uint8
|
1
|
0
|
1
|
0 - Disable
|
Send data with 0, if ignition is off
|
1 - Enable
|
Configuration example
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
2000
|
Uint8
|
-
|
0
|
3
|
0 – Disabled
|
Priority
|
1 – Low
|
2 – High
|
3 – Panic
|
2001
|
Uint8
|
3
|
0
|
4
|
0 - On range exit
|
Generation type
|
1 - On range entrance
|
2 - On both
|
3 - Monitoring
|
4 - Hysteresis
|
5 - On change
|
2002
|
Uint8
|
-
|
0
|
255
|
High value
|
High level
|
2003
|
Uint8
|
0
|
0
|
255
|
Low value
|
Low level
|
2004
|
Uint8
|
-
|
0
|
265535
|
value
|
Average constant value
|
Allowed values
CAN IO Element
|
Minimum value
|
Maximum value
|
Speed
|
0
|
250
|
Accelerator pedal position
|
0
|
100
|
Total fuel used
|
0
|
99999999
|
Fuel level (liters)
|
0
|
100
|
Engine RPM
|
0
|
8200
|
Vehicle distance
|
0
|
2145000000
|
Fuel level (proc.)
|
0
|
100
|
Program number
|
0
|
999
|
Other CAN settings
Similarly to a group defined in the upper table:
Name
|
Parameter
|
Priority
|
Generation type
|
Low level
|
High level
|
Avg const'
|
Vehicle speed |
2000 |
2001 |
2002 |
2003 |
2004
|
Acceleration Pedal Position |
2010 |
2011 |
2012 |
2013 |
2014
|
Total fuel used |
2020 |
2021 |
2022 |
2023 |
-
|
Fuel level (liters) |
2030 |
2031 |
2032 |
2033 |
2034
|
Engine RPM |
2040 |
2041 |
2042 |
2043 |
2044
|
Total Mileage |
2050 |
2051 |
2052 |
2053 |
-
|
Fuel Level (percent) |
2060 |
2061 |
2062 |
2063 |
2064
|
Program Number |
2070 |
2071 |
2072 |
2073 |
-
|
Module ID |
2080 |
2081 |
2082 |
2083 |
-
|
Engine Worktime |
2090 |
2091 |
2092 |
2093 |
-
|
Engine Worktime (counted) |
2100 |
2101 |
2102 |
2103 |
-
|
Total Mileage (counted) |
2110 |
2111 |
2112 |
2113 |
-
|
Fuel Consumed (counted) |
2120 |
2121 |
2122 |
2123 |
-
|
Fuel Rate |
2130 |
2131 |
2132 |
2133 |
2134
|
AdBlue Level (percent) |
2140 |
2141 |
2142 |
2143 |
2144
|
AdBlue Level (liters) |
2150 |
2151 |
2152 |
2153 |
2154
|
Engine Load |
2160 |
2161 |
2162 |
2163 |
2164
|
Engine Temperature |
2170 |
2171 |
2172 |
2173 |
2174
|
Axle 1 Load |
2180 |
2181 |
2182 |
2183 |
2184
|
Axle 2 Load |
2190 |
2191 |
2192 |
2193 |
2194
|
Axle 3 Load |
2200 |
2201 |
2202 |
2203 |
2204
|
Axle 4 Load |
2210 |
2211 |
2212 |
2213 |
2214
|
Axle 5 Load |
2220 |
2221 |
2222 |
2223 |
2224
|
Control State Flags |
2230 |
2231 |
2232 |
2233 |
-
|
Agricultural Machinery Flags |
2240 |
2241 |
2242 |
2243 |
-
|
Harvesting Time |
2250 |
2251 |
2252 |
2253 |
-
|
Area of Harvest |
2260 |
2261 |
2262 |
2263 |
-
|
Mowing Efficiency |
2270 |
2271 |
2272 |
2273 |
2274
|
Grain Mown Volume |
2280 |
2281 |
2282 |
2283 |
-
|
Grain Moisture |
2290 |
2291 |
2292 |
2293 |
2294
|
Harvesting Drum RPM |
2300 |
2301 |
2302 |
2303 |
2304
|
Gap Under Harvesting Drum |
2310 |
2311 |
2312 |
2313 |
2314
|
Security State Flags |
2320 |
2321 |
2322 |
2323 |
-
|
Tachograph Total Vehicle Distance |
2330 |
2331 |
2332 |
2333 |
-
|
Trip Distance |
2340 |
2341 |
2342 |
2343 |
-
|
Tachograph Vehicle Speed |
2350 |
2351 |
2352 |
2353 |
2354
|
Tachograph Driver Card Presence |
2360 |
2361 |
2362 |
2363 |
-
|
Driver 1 States |
2370 |
2371 |
2372 |
2373 |
-
|
Driver 2 States |
2380 |
2381 |
2382 |
2383 |
-
|
Driver 1 Continuous Driving Time |
2390 |
2391 |
2392 |
2393 |
-
|
Driver 2 Continuous Driving Time |
2400 |
2401 |
2402 |
2403 |
-
|
Driver 1 Cumulative Break Time |
2410 |
2411 |
2412 |
2413 |
-
|
Driver 2 Cumulative Break Time |
2420 |
2421 |
2422 |
2423 |
-
|
Driver 1 Selected Activity Duration |
2430 |
2431 |
2432 |
2433 |
-
|
Driver 2 Selected Activity Duration |
2440 |
2441 |
2442 |
2443 |
-
|
Driver 1 Cumulative Driving Time |
2450 |
2451 |
2452 |
2453 |
-
|
Driver 2 Cumulative Driving Time |
2460 |
2461 |
2462 |
2463 |
-
|
Driver 1 ID High |
2470 |
2471 |
2472 |
2473 |
-
|
Driver 1 ID Low |
2480 |
2481 |
2482 |
2483 |
-
|
Driver 2 ID High |
2490 |
2491 |
2492 |
2493 |
-
|
Driver 2 ID Low |
2500 |
2501 |
2502 |
2503 |
-
|
Battery temperature |
2510 |
2511 |
2512 |
2513 |
2514
|
Battery level |
2520 |
2521 |
2522 |
2523 |
2524
|
Door Status |
2530 |
2531 |
2532 |
2533 |
-
|
DTC Faults |
2540 |
2541 |
2542 |
2543 |
-
|
Slope Of Arm |
2550 |
2551 |
2552 |
2553 |
-
|
Rotation of Arm |
2560 |
2561 |
2562 |
2563 |
-
|
Eject of Arm |
2570 |
2571 |
2572 |
2573 |
-
|
Horizontal Distance Arm Vehicle |
2580 |
2581 |
2582 |
2583 |
-
|
Height Arm Above Ground |
2590 |
2591 |
2592 |
2593 |
-
|
Drill RPM |
2600 |
2601 |
2602 |
2603 |
-
|
Amount of Spread Salt Square Meter |
2610 |
2611 |
2612 |
2613 |
-
|
Battery Voltage |
2620 |
2621 |
2622 |
2623 |
-
|
Amount of Spread Fine Grained Salt |
2630 |
2631 |
2632 |
2633 |
-
|
Amount of Spread Coarse Grained Salt |
2640 |
2641 |
2642 |
2643 |
-
|
Amount of Spread DiMix |
2650 |
2651 |
2652 |
2653 |
-
|
Amount of Spread Coarse Grained Calcium |
2660 |
2661 |
2662 |
2663 |
-
|
Amount of Spread Calcium Chloride |
2670 |
2671 |
2672 |
2673 |
-
|
Amount of Spread Sodium Chloride |
2680 |
2681 |
2682 |
2683 |
-
|
Amount of Spread Magnesium Chloride |
2690 |
2691 |
2692 |
2693 |
-
|
Amount of Spread Gravel |
2700 |
2701 |
2702 |
2703 |
-
|
Amount of Spread Sand |
2710 |
2711 |
2712 |
2713 |
-
|
Width Pouring Left |
2720 |
2721 |
2722 |
2723 |
-
|
Width Pouring Right |
2730 |
2731 |
2732 |
2733 |
-
|
Salt Spreader Working Hours |
2740 |
2741 |
2742 |
2743 |
-
|
Distance During Salting |
2750 |
2751 |
2752 |
2753 |
-
|
Load Weight |
2760 |
2761 |
2762 |
2763 |
-
|
Retarder Load |
2770 |
2771 |
2772 |
2773 |
-
|
Cruise Time |
2780 |
2781 |
2782 |
2783 |
-
|
CNG Status |
2790 |
2791 |
2792 |
2793 |
-
|
CNG Used |
2800 |
2801 |
2802 |
2803 |
-
|
CNG Level |
2810 |
2811 |
2812 |
2813 |
-
|
Oil Level |
2820 |
2821 |
2822 |
2823 |
-
|