Difference between revisions of "Template:FMB1 Accessories"
From Wiki Knowledge Base | Teltonika GPS
m |
|||
Line 15: | Line 15: | ||
! style="text-align: left; vertical-align: top;" |Fuel tank sensors | ! style="text-align: left; vertical-align: top;" |Fuel tank sensors | ||
− | ! style="text-align: | + | ! style="text-align: center; vertical-align: top;" |Fuel sensor connection to {{{model|FMB1YX}}} |
|- | |- | ||
| style="text-align: left; vertical-align: top;" |A fuel tank level sensor which indicates the approximate fuel level on the driver's indicator panel exists in most cars. If the sensor returns analogue signal proportional to fuel level it can be connected to {{{model|FMB1YX}}} Analog input. After connection to the tank fuel level sensor a calibration is needed because most fuel tank sensors are not linear. Calibration is performed by measuring voltage values resulting from the volume of fuel in tank. | | style="text-align: left; vertical-align: top;" |A fuel tank level sensor which indicates the approximate fuel level on the driver's indicator panel exists in most cars. If the sensor returns analogue signal proportional to fuel level it can be connected to {{{model|FMB1YX}}} Analog input. After connection to the tank fuel level sensor a calibration is needed because most fuel tank sensors are not linear. Calibration is performed by measuring voltage values resulting from the volume of fuel in tank. | ||
Line 21: | Line 21: | ||
|- | |- | ||
! style="text-align: left; vertical-align: top;" |Alarm buttons, door sensors etc. | ! style="text-align: left; vertical-align: top;" |Alarm buttons, door sensors etc. | ||
− | ! style="text-align: | + | ! style="text-align: center; vertical-align: top;" |Panic button connection to {{{model|FMB1YX}}} |
|- | |- | ||
| style="text-align: left; vertical-align: top;" |Alarm buttons, door sensors, ignition, etc. have two output states: high or low. {{{model|FMB1YX}}} Digital inputs are used to detect these states. | | style="text-align: left; vertical-align: top;" |Alarm buttons, door sensors, ignition, etc. have two output states: high or low. {{{model|FMB1YX}}} Digital inputs are used to detect these states. | ||
Line 27: | Line 27: | ||
|- | |- | ||
! style="text-align: left; vertical-align: top;" |Relays | ! style="text-align: left; vertical-align: top;" |Relays | ||
− | ! style="text-align: | + | ! style="text-align: center; vertical-align: top;" |Inverting relay connection to {{{model|FMB1YX}}} |
|- | |- | ||
| style="text-align: left; vertical-align: top;" |In cases when sensor output signal is negative, an additional relay has to be installed to convert negative signal to positive. | | style="text-align: left; vertical-align: top;" |In cases when sensor output signal is negative, an additional relay has to be installed to convert negative signal to positive. | ||
Line 33: | Line 33: | ||
|- | |- | ||
! style="text-align: left; vertical-align: top;" |Immobilizer relay | ! style="text-align: left; vertical-align: top;" |Immobilizer relay | ||
− | ! style="text-align: | + | ! style="text-align: center; vertical-align: top;" |Immobilizer relay connection to {{{model|FMB1YX}}} output |
|- | |- | ||
| style="text-align: left; vertical-align: top;" |When connected as shown on the right hand side, {{{model|FMB1YX}}} disables engine starter when output is ON. | | style="text-align: left; vertical-align: top;" |When connected as shown on the right hand side, {{{model|FMB1YX}}} disables engine starter when output is ON. | ||
Line 39: | Line 39: | ||
|- | |- | ||
! style="text-align: left; vertical-align: top;" |Automotive relay | ! style="text-align: left; vertical-align: top;" |Automotive relay | ||
− | ! style="text-align: | + | ! style="text-align: center; vertical-align: top;" |Automotive relay pinout |
|- | |- | ||
|- | |- | ||
Line 46: | Line 46: | ||
|- | |- | ||
! style="text-align: left; vertical-align: top;" |{{{oneWire|1-Wire devices}}} | ! style="text-align: left; vertical-align: top;" |{{{oneWire|1-Wire devices}}} | ||
− | ! style="text-align: | + | ! style="text-align: center; vertical-align: top;" |{{{oneWire|Digital thermometer DS1820 and TTJ100 connection to {{{model|FMB1YX}}} }}} |
|- | |- | ||
| rowspan="5" style="text-align: left; vertical-align: top;" |{{{oneWire|One of the implemented features on {{{model|FMB1YX}}} is 1-Wire® data protocol, which enables connection to devices such as thermometer (DS1820, DS18S20 and DS18B20) and I-Button DS1990A. }}} | | rowspan="5" style="text-align: left; vertical-align: top;" |{{{oneWire|One of the implemented features on {{{model|FMB1YX}}} is 1-Wire® data protocol, which enables connection to devices such as thermometer (DS1820, DS18S20 and DS18B20) and I-Button DS1990A. }}} | ||
Line 54: | Line 54: | ||
| style="text-align: left; vertical-align: top;" |{{{oneWire| {{{pic_ds1820|[[Image:Sch_fmb120_ds1820.png|400px|center]]}}} }}} | | style="text-align: left; vertical-align: top;" |{{{oneWire| {{{pic_ds1820|[[Image:Sch_fmb120_ds1820.png|400px|center]]}}} }}} | ||
|- | |- | ||
− | + | ! style="text-align: center; vertical-align: top;" |{{{oneWire| TTJ sensor pinout }}} | |
|- | |- | ||
| style="text-align: left; vertical-align: top;" |{{{oneWire| [[Image:Ttj_pinout.png|400px|center]] }}} | | style="text-align: left; vertical-align: top;" |{{{oneWire| [[Image:Ttj_pinout.png|400px|center]] }}} | ||
|- | |- | ||
− | ! style="text-align: | + | ! style="text-align: center; vertical-align: top;" |{{{oneWire| I-Button DS1990A connection to {{{model|FMB1YX}}} }}} |
|- | |- | ||
| style="text-align: left; vertical-align: top;" |{{{oneWire| [[Image:Sch_fmb1yx_ibutton.png|400px|center]] }}} | | style="text-align: left; vertical-align: top;" |{{{oneWire| [[Image:Sch_fmb1yx_ibutton.png|400px|center]] }}} | ||
|- | |- | ||
|} | |} |
Revision as of 11:55, 30 June 2021
Please order accessories separately as they are not included into device package. |
Accessory and its description | Accessory connection schematic |
---|---|
Fuel tank sensors | Fuel sensor connection to FMB1YX |
A fuel tank level sensor which indicates the approximate fuel level on the driver's indicator panel exists in most cars. If the sensor returns analogue signal proportional to fuel level it can be connected to FMB1YX Analog input. After connection to the tank fuel level sensor a calibration is needed because most fuel tank sensors are not linear. Calibration is performed by measuring voltage values resulting from the volume of fuel in tank. | |
Alarm buttons, door sensors etc. | Panic button connection to FMB1YX |
Alarm buttons, door sensors, ignition, etc. have two output states: high or low. FMB1YX Digital inputs are used to detect these states. | |
Relays | Inverting relay connection to FMB1YX |
In cases when sensor output signal is negative, an additional relay has to be installed to convert negative signal to positive. | |
Immobilizer relay | Immobilizer relay connection to FMB1YX output |
When connected as shown on the right hand side, FMB1YX disables engine starter when output is ON. | |
Automotive relay | Automotive relay pinout |
An ordinary automotive relay is used to invert input signal or to immobilize engine starter. Note that relays can be 12 V or 24 V capable. |
|
1-Wire devices | Digital thermometer DS1820 and TTJ100 connection to FMB1YX |
One of the implemented features on FMB1YX is 1-Wire® data protocol, which enables connection to devices such as thermometer (DS1820, DS18S20 and DS18B20) and I-Button DS1990A.
|
|
TTJ sensor pinout | |
I-Button DS1990A connection to FMB1YX | |