Difference between revisions of "Secure vehicle disabling"

From Wiki Knowledge Base | Teltonika GPS
Line 127: Line 127:
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |Timestamp
 
| style="vertical-align: middle; text-align: center;" |Timestamp
| style="vertical-align: middle; text-align: center;" |00 00 01 77 4D 66 D5 A8
+
| style="vertical-align: middle; text-align: center;" |00 00 01 77 4D 66 D5 A8 (Friday, January 29, 2021 9:08:41 AM)
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |Priority
 
| style="vertical-align: middle; text-align: center;" |Priority
Line 160: Line 160:
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |1’st IO ID
 
| style="vertical-align: middle; text-align: center;" |1’st IO ID
| style="vertical-align: middle; text-align: center;" |00 EF
+
| style="vertical-align: middle; text-align: center;" |00 EF (AVL ID: 239; Name: Ignition)
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |1’st IO Value
 
| style="vertical-align: middle; text-align: center;" |1’st IO Value
Line 166: Line 166:
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |2’nd IO ID
 
| style="vertical-align: middle; text-align: center;" |2’nd IO ID
| style="vertical-align: middle; text-align: center;" |00 F0
+
| style="vertical-align: middle; text-align: center;" |00 F0 (AVL ID: 240; Name: Movement)
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |2’nd IO Value
 
| style="vertical-align: middle; text-align: center;" |2’nd IO Value
Line 172: Line 172:
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |3’th IO ID
 
| style="vertical-align: middle; text-align: center;" |3’th IO ID
| style="vertical-align: middle; text-align: center;" |00 B3
+
| style="vertical-align: middle; text-align: center;" |00 B3 (AVL ID: 179; Name: Digital Output 1)
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |3’th IO Value
 
| style="vertical-align: middle; text-align: center;" |3’th IO Value
Line 196: Line 196:
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |Timestamp
 
| style="vertical-align: middle; text-align: center;" |Timestamp
| style="vertical-align: middle; text-align: center;" |00 00 01 77 4D 66 D9 90
+
| style="vertical-align: middle; text-align: center;" |00 00 01 77 4D 66 D9 90 (Friday, January 29, 2021 9:08:42 AM)
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |Priority
 
| style="vertical-align: middle; text-align: center;" |Priority
Line 229: Line 229:
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |1’st IO ID
 
| style="vertical-align: middle; text-align: center;" |1’st IO ID
| style="vertical-align: middle; text-align: center;" |00 EF
+
| style="vertical-align: middle; text-align: center;" |00 EF (AVL ID: 239; Name: Ignition)
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |1’st IO Value
 
| style="vertical-align: middle; text-align: center;" |1’st IO Value
Line 235: Line 235:
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |2’nd IO ID
 
| style="vertical-align: middle; text-align: center;" |2’nd IO ID
| style="vertical-align: middle; text-align: center;" |00 F0
+
| style="vertical-align: middle; text-align: center;" |00 F0 (AVL ID: 240; Name: Movement)
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |2’nd IO Value
 
| style="vertical-align: middle; text-align: center;" |2’nd IO Value
Line 241: Line 241:
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |3’th IO ID
 
| style="vertical-align: middle; text-align: center;" |3’th IO ID
| style="vertical-align: middle; text-align: center;" |00 B3
+
| style="vertical-align: middle; text-align: center;" |00 B3 (AVL ID: 179; Name: Digital Output 1)
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |3’th IO Value
 
| style="vertical-align: middle; text-align: center;" |3’th IO Value
Line 270: Line 270:
 
| style="vertical-align: middle; text-align: center;" |00 00 A6 5F
 
| style="vertical-align: middle; text-align: center;" |00 00 A6 5F
 
|}
 
|}
 +
 +
== In platform ==
 +
TAVL: Open TAVL → select client → select Street Map → select device → choose the date from which to which to show the records → push advanced → push show button and then you will see in left down corner all information.
 +
[[File:Seco 2.png|alt=|frameless|center|1155x1155px]]
 +
<br />
 +
[[File:Seco 2.png|alt=|frameless|center|1155x1155px]]

Revision as of 21:11, 18 February 2021

Main Page > General Information > Usage scenarios > Secure vehicle disabling

Project description

Motor vehicle theft is one of the world’s biggest concerns and the fastest growing crimes in many countries around the world. This great challenge for car rental agencies, car sharing clubs, businesses, state organizations and private car owners caused properly losses of over 6 billion US dollar globally in 2018. Luckily for them, Teltonika GPS trackers gave a remote secure engine cut-off (SECO) functionality that can help to recover a stolen vehicle and prevent the loss.

We glad that you decided to test our “Secure vehicle disabling” solution.

Here you will find how to prepare and to test this solution.

What you need for a solution?

  • The secure vehicle disabling solution is supported by any Teltonika FMB series tracker which has one or more digital output (DOUT) which in this scenario is used to control fuel pump of the car.
  • The SIM card in order to get data to your server.
  • The secure engine cut-off (SECO) functionality is only available in Teltonika FMB series GPS trackers starting with the firmware version 03.25.10.Rev.110 or higher.
  • FOTA WEB to remotely send the configuration to the device.

Installation

It’s important to well hide tracker, so it would not be a simple task for the thieves to find and unplug it. But also, please do not forget to follow mounting recommendations as well. Although devices have high gain antennas it’s important to mount devices with stickers on top and in metal-free space. The device should be firmly fixed to the surface or cables. Please make sure, that device is not fixed to heat emitting or moving parts.


During installation please follow recommendations in order to avoid damaging device and vehicle:

  • Wires should be connected while the module is not plugged in.
  • Be sure that after the car computer falls asleep, power is still available on the chosen wire. Depending on the car, this may happen in a 5 to 30 minutes period.
  • When the module is connected, be sure to measure the voltage again if it did not decrease.
  • The ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.

Configuration

1. Prerequisites:

1.1. Read through First start guide

1.2. Understanding of possible Sleep modes.

2. Configuring SECO scenario

Parameter ID - Parameter name GPRS settings:

  • 2001 – APN
  • 2002 – APN username (if there are no APN username, empty field should be left)
  • 2003 – APN password (if there are no APN password, empty field should be left)


Server settings:

  • 2004 – Domain
  • 2005 – Port
  • 2006 – Data sending protocol (0 – TCP, 1 – UDP)


After successful GPRS/SERVER settings configuration, FMB130 device will synchronize time and update records to the configured server. Time intervals and default I/O elements can be changed by using Teltonika Configurator or SMS parameters.


Sleep settings:

  • 102 – Sleep settings(0 – Disable, 1 – Gps sleep, 2 – Deep sleep, 3 – Online Deep sleep, 4 – Ultra sleep)
  • Note: This scenario will not work with Deep Sleep and Ultra Deep Sleep since they disable the device's GSM module to save power.




SECO scenario settings:

  • 12250 – Scenario priority
  • 12251 – Eventual settings (0 – Disable, 1 – Enable)
  • 12252 – Output Control (0 – None, 1 – DOUT1, 2 – DOUT2, 3 – DOUT3)
  • 12254 - Speed (km/h)
  • 12259 - Speed Pulse Scenario (km/h)
  • 12255 - Speed check period (s)
  • 12256 - Movement timeout (s)
  • 12253 - Output Pulse (0 – Disable, 1 – Enable)
  • 12257 – DOUT ON Duration (ms)
  • 12258 – DOUT OFF Duration (ms)
  • 7377 - Send SMS To
  • 8377 – SMS text








Quick start: From default configuration to SECO detection in one SMS:

"  setparam 2001:APN;2002:APN_username;2003:APN_password;2004:Domain;2005:Port;2006:0;102:1;12250:2;12252:1"

Pharsing SECO records

1.Prerequisites:

1.1. Open TCP/UDP port

1.2. Go to Java parser first start guide

2. Parsing example:

Unparsed received data in hexadecimal stream
00000000000000678E02000001774D66D5A8010F1267D220979FC600BE00C1050028018C0004000400EF0100

F00100B300018C010000000000000000000001774D66D990010F12663120979BFF00BE00C1050028018C0004

000400EF0100F00100B300018C020000000000000000020000A65F

AVL Data Packet
AVL Data Packet Part HEX Code Part
Zero Bytes 00 00 00 00
Data Field Length 00 00 00 67
Codec ID 8E (Codec 8 Extended)
Number of Data 1 (Records) 02
Timestamp 00 00 01 77 4D 66 D5 A8 (Friday, January 29, 2021 9:08:41 AM)
Priority 01
Longitude 0F 12 67 D2
Latitude 20 97 9F C6
Altitude 00 BE
Angle 00 C1
Satellites 05
Speed 00 28
Event IO ID 01 8C (AVL ID: 396, Name: Seco)
of Total ID 00 04
of One Byte IO 00 04
1’st IO ID 00 EF (AVL ID: 239; Name: Ignition)
1’st IO Value 01
2’nd IO ID 00 F0 (AVL ID: 240; Name: Movement)
2’nd IO Value 01
3’th IO ID 00 B3 (AVL ID: 179; Name: Digital Output 1)
3’th IO Value 00
4’th IO ID 01 8C (AVL ID: 396, Name: Seco)
4’th IO Value 01 ( 0 - SECO DOUT OFF; 1- SECO DOUT pulsing; 2 - SECO DOUT ON)
N2 of Two Bytes IO 00 00
N4 of Two Bytes IO 00 00
N8 of Two Bytes IO 00 00
NX of X Byte IO 00 00
Timestamp 00 00 01 77 4D 66 D9 90 (Friday, January 29, 2021 9:08:42 AM)
Priority 01
Longitude 0F 12 66 3
Latitude 20 97 9B FF
Altitude 00 BE
Angle 00 C1
Satellites 05
Speed 00 28
Event IO ID 01 8C (AVL ID: 396, Name: Seco)
of Total ID 00 04
of One Byte IO 00 04
1’st IO ID 00 EF (AVL ID: 239; Name: Ignition)
1’st IO Value 01
2’nd IO ID 00 F0 (AVL ID: 240; Name: Movement)
2’nd IO Value 01
3’th IO ID 00 B3 (AVL ID: 179; Name: Digital Output 1)
3’th IO Value 00
4’th IO ID 01 8C (AVL ID: 396, Name: Seco)
4’th IO Value 02 ( 0 - SECO DOUT OFF; 1- SECO DOUT pulsing; 2 - SECO DOUT ON)
N2 of Two Bytes IO 00 00
N4 of Two Bytes IO 00 00
N8 of Two Bytes IO 00 00
NX of X Byte IO 00 00
Number of Data 2 (Number of Total Records) 02
CRC-16 00 00 A6 5F

In platform

TAVL: Open TAVL → select client → select Street Map → select device → choose the date from which to which to show the records → push advanced → push show button and then you will see in left down corner all information.