FMB120 First Start: Difference between revisions
Atabasnikov (talk | contribs) mNo edit summary |
Atabasnikov (talk | contribs) mNo edit summary |
||
Line 112: | Line 112: | ||
<font size="+3"><span style=color:#104996>'''How to install FMB120 drivers'''</span></font> | <font size="+3"><span style=color:#104996>'''How to install FMB120 drivers (Windows)'''</span></font> | ||
<font size="+2"><span style=color:#F49E21> 1. </span> | <font size="+2"><span style=color:#F49E21> 1. </span> Please download COM port drivers from Teltonika website: https://teltonika.lt/?media_dl=5543. </font> | ||
<font size="+2"><span style=color:#F49E21> 2. </span> Extract and run TeltonikaCOMDriver.exe. This driver is used to detect FMB120 device when it is connected to the computer. </font> | |||
<font size="+2"><span style=color:#F49E21> 3. </span> Click 'Next' in driver installation window. </font> | |||
<font size="+2"><span style=color:#F49E21> 4. </span> In the following window click 'Install' button. </font> | |||
<font size="+2"><span style=color:#F49E21> 5. </span> Setup will continue install driver and will display a windows confirming that installation process is complete. Click 'Finish' to complete setup. You are now ready to use the device on your computer. </font> | |||
<font size="+3"><span style=color:#104996>'''Configuration (Windows)'''</span></font><br/> | |||
<font size="+2"><span style=color:#104996>.NET requirements</span></font> | <font size="+2"><span style=color:#104996>.NET requirements</span></font> | ||
Line 143: | Line 155: | ||
|} | |} | ||
<font size="+ | <font size="+1"> | ||
When delivered FMB120 module has default factory settings. Settings should be changed according to your application and your GSM operator information.<br/> | |||
It can be configured to acquire and send data to server. If device is not able to send data to server, GSM is not available and FMB120 will start storing records to flash memory. It is possible to store up to 192000 data records with 128 MB SD memory card (when 100 MB are used to store records). It will send data over GPRS when it is available. Note that FMB120 can have memory full of records. Then it will start deleting oldest records in order to save new ones.<br/> | |||
FMB120 configuration is performed via FMB120 Configurator program. Contact sales manager to get the latest FMB120 Configurator version or download from https://teltonika.lt/?media_dl=7290. FMB120 configurator operates on Microsoft Windows OS and uses prerequisite MS .NET Framework. | |||
Module configuration is performed over USB cable or Bluetooth port. Configuration process starts from starting FMB120 Configurator software and then connecting to FMB120 device via 'Connect' button located in 'Online' menu part. FMB120 has one user editable profile, which can be loaded from device, and saved. User can also revert to default settings, by pressing 'Reset to defaults' button. After any modification of configuration settings the changes have to be saved to FMB120 device.<br/> | |||
</font> | |||
Revision as of 09:47, 10 April 2018
Main Page > Advanced Trackers > FMB120 > FMB120 First Start
FMB120 GNSS/GSM/Bluetooth tracker with internal GNSS/GSM antennas and internal battery
Quick Start Guide
How to insert micro SIM card into FMB120
1. Remove FMB120 cover.
2. Insert SIM card as shown. SIM slot 1 is closer to PCB, SIM slot 2 is the upper one.
3. Attach cover.
4. Device is ready.
2x6 socket pinout
Pin number | Pin name | Description |
---|---|---|
1 | VCC (10-30)V DC (+) | Power supply (+10-30 V DC). |
2 | AIN 1 | Analog input, channel 1. Input range: 0-30 V DC. |
3 | AIN 2 / DIN 3 | Analog input, channel 2. Input range: 0-30 V DC / Digital input, channel 3. |
4 | DIN 2 | Digital input, channel 2. |
5 | DIN 1 | Digital input, channel 1. |
6 | INPUT 6 | TX EXT (LVCAN – TX). |
7 | GND (-) | Ground. |
8 | OUT 1 | Digital output, channel 1. Open collector output. Max. 3,3 A DC. |
9 | OUT 2 | Digital output, channel 2. Open collector output. Max. 3,3 A DC. |
10 | 1WIRE POWER | +3,8 V output for 1–Wire devices. |
11 | 1WIRE DATA | Data for 1–Wire devices. |
12 | INPUT 5 | RX EXT (LVCAN - RX). |
How to install FMB120 drivers (Windows)
1. Please download COM port drivers from Teltonika website: https://teltonika.lt/?media_dl=5543.
2. Extract and run TeltonikaCOMDriver.exe. This driver is used to detect FMB120 device when it is connected to the computer.
3. Click 'Next' in driver installation window.
4. In the following window click 'Install' button.
5. Setup will continue install driver and will display a windows confirming that installation process is complete. Click 'Finish' to complete setup. You are now ready to use the device on your computer.
Configuration (Windows)
.NET requirements
Operating system | MS .NET Framework version | Version | Links |
---|---|---|---|
Windows XP with SP3 or later | MS .NET Framework 4 with KB2468871-v2 update | 32 and 64 bit | https://www.microsoft.com/en-US/Download/confirmation.aspx?id=17718 |
32 bit (x86) , 64 bit (x64 or IA64) | https://www.microsoft.com/en-us/download/details.aspx?id=3556
http://avl1.teltonika.lt/downloads/software/Framework/.NET%20Framework%204%20update%20KB2468871-v2/ | ||
Windows Vista Windows 7 Windows 8.1 Windows 10 |
MS .NET Framework 4.6.2 | 32 and 64 bit | https://www.microsoft.com/en-us/download/confirmation.aspx?id=53344 |
When delivered FMB120 module has default factory settings. Settings should be changed according to your application and your GSM operator information.
It can be configured to acquire and send data to server. If device is not able to send data to server, GSM is not available and FMB120 will start storing records to flash memory. It is possible to store up to 192000 data records with 128 MB SD memory card (when 100 MB are used to store records). It will send data over GPRS when it is available. Note that FMB120 can have memory full of records. Then it will start deleting oldest records in order to save new ones.
FMB120 configuration is performed via FMB120 Configurator program. Contact sales manager to get the latest FMB120 Configurator version or download from https://teltonika.lt/?media_dl=7290. FMB120 configurator operates on Microsoft Windows OS and uses prerequisite MS .NET Framework.
Module configuration is performed over USB cable or Bluetooth port. Configuration process starts from starting FMB120 Configurator software and then connecting to FMB120 device via 'Connect' button located in 'Online' menu part. FMB120 has one user editable profile, which can be loaded from device, and saved. User can also revert to default settings, by pressing 'Reset to defaults' button. After any modification of configuration settings the changes have to be saved to FMB120 device.
Safety information
This message contains information on how to operate FMB120 safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!
The device uses SELV limited power source. The nominal voltage is +12 V DC. The allowed range of voltage is +10-30 V DC.
To avoid mechanical damage, it is advised to transport the device in an impact-proof package. Before usage, the device should be placed so that its LED indicators are visible, which show the status of device operation.
When connecting the 2x6 connector wires to the vehicle, the appropriate jumpers of the vehicle power supply should be disconnected.
Before unmounting the device from the vehicle, the 2x6 connector must be disconnected.
The device is designed to be mounted in a zone of limited access, which is inaccessible to the operator. All related devices must meet the requirements of EN 60950-1 standard.
The device FMB120 is not designed as a navigational device for boats.
Precautions
https://teltonika.lt/product/fmb120-internal-gnss-antenna-battery/