Difference between revisions of "Template:FMB CAN adapters"
From Wiki Knowledge Base | Teltonika GPS
Atabasnikov (talk | contribs) m |
Atabasnikov (talk | contribs) m |
||
Line 1: | Line 1: | ||
− | ==Purpose of Can Adapters LV-CAN200 and ALL- | + | ==Purpose of Can Adapters LV-CAN200 and ALL-CAN300== |
+ | |||
+ | [[Image:Fmb120_can_connx_diagram.png|300px|center]] | ||
+ | LV-CAN200 is used to listening data from light vehicles, while ALL-CAN300 is used to listening data from any type of transport: light vehicles, Trucks, buses, agriculture and other special transport. With those adapters FMB120 device is able to collect and send vehicle data. | ||
+ | |||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! style="width: 200px; background: black; color: white;" | Parameter | ||
+ | ! style="width: 300px; background: black; color: white;" | Value | ||
+ | |- | ||
+ | ! style="text-align: left; vertical-align: top;" | Supply voltage | ||
+ | | style="text-align: left; vertical-align: top;" | 9 to 50 V | ||
+ | |- | ||
+ | ! style="text-align: left; vertical-align: top;" | Power supply current | ||
+ | | style="text-align: left; vertical-align: top;" | Average 10 mA. Max (peak) 100 mA | ||
+ | |- | ||
+ | ! style="text-align: left; vertical-align: top;" | Working temperature | ||
+ | | style="text-align: left; vertical-align: top;" | -40..+85 ºC | ||
+ | |- | ||
+ | ! style="text-align: left; vertical-align: top;" | Max working humidity | ||
+ | | style="text-align: left; vertical-align: top;" | 60 % (non condensate). | ||
+ | |- | ||
+ | |} | ||
==LV-CAN200 and ALL-CAN300 program number selection== | ==LV-CAN200 and ALL-CAN300 program number selection== | ||
===LV-CAN200 and ALL-CAN300 program number configuration via SMS command=== | ===LV-CAN200 and ALL-CAN300 program number configuration via SMS command=== |
Revision as of 15:24, 11 April 2018
Purpose of Can Adapters LV-CAN200 and ALL-CAN300
LV-CAN200 is used to listening data from light vehicles, while ALL-CAN300 is used to listening data from any type of transport: light vehicles, Trucks, buses, agriculture and other special transport. With those adapters FMB120 device is able to collect and send vehicle data.
Parameter | Value |
---|---|
Supply voltage | 9 to 50 V |
Power supply current | Average 10 mA. Max (peak) 100 mA |
Working temperature | -40..+85 ºC |
Max working humidity | 60 % (non condensate). |