Functionality description
If this function is active, then all other settings associated with the this input are disabled.
Frequency measurement can be performed in 2 different ways:
- Frequency is measured by counting pulses over time period (997 ms). Method is used for frequencies higher than 100 Hz.
- Frequency is measured by measuring time between pulses. Method is used for frequencies lower than 100 Hz.
Parameter values
System parameters (ID = 145). Device/Available/Input port/Frequency:
Device | DIN1 | DIN2 | DIN4 | |||
---|---|---|---|---|---|---|
50Hz | 2kHz | 50Hz | 2kHz | 50Hz | 2kHz | |
FMB0 | + | |||||
FMB110/FMB120/FMB130/FMB140 | + | + | ||||
FMB202/FMB204/FMB209 | + | + | ||||
FMB920 | ||||||
FMC130 | ||||||