{| class="wikitable" | |||
|+ | |||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Parameted ID''' | |||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Parameter Type''' | |||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Default value''' | |||
! style="width: 150px; background: black; color: white;" colspan=2 |'''Value range''' | |||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Value''' | |||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Parameter name''' | |||
|- | |||
! style="width: 75px; background: black; color: white;" |Min | |||
! style="width: 75px; background: black; color: white;" |Max | |||
|- | |||
| 11200||Uint8||0||0||3||0 – Disable||Scenario settings|| | |||
|- | |||
| ||||||||||1 – Low priority|||| | |||
|- | |||
| ||||||||||2 – High priority|||| | |||
|- | |||
| ||||||||||3 – Panic priority|||| | |||
|- | |||
| 11203||Uint8||1||0||1||0 – Disable||Eventual records|| | |||
|- | |||
| ||||||||||1 – Enable|||| | |||
|- | |||
| 11205||Uint8||5||0||255||Seconds||Time to stoped|| | |||
|- | |||
| 11206||Uint8||2||0||255||Seconds||Time to moving|| | |||
|- | |||
| 11204||Uint8||0||0||1||0 – None||Output control|| | |||
|- | |||
| ||||||||||1 – DOUT 1|||| | |||
|- | |||
| 11201||Int32||200||0||2147483647||Milliseconds||DOUT ON duration|| | |||
|- | |||
| 11202||Int32||200||0||2147483647||Milliseconds||DOUT OFF duration|| | |||
|- | |||
| 7033||Uint8||0||0||10||Phone number||Send SMS to|| | |||
|- | |||
| 8033||String||"Idling Event"||0||160||Text||Sms text|| | |||
|- | |||
| | |||
|} | |||
==Bluetooth== | ==Bluetooth== | ||
==iButton List== | ==iButton List== |
Revision as of 12:10, 13 April 2018
System parameters
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
100 | Uint8 | 0 | 0 | 2 | 0 – Ignition | Movement source |
1 – Movement | ||||||
2 – GPS | ||||||
106 | Uint8 | 1 | 0 | 1 | 0 – Disable | Static navigation |
1 – Enable | ||||||
107 | Uint8 | 0 | 0 | 1 | 0 – Disable | Send/Save records without TS |
1 – Enable | ||||||
108 | Uint8 | 1 | 0 | 1 | 0 – Disable | LED Indication |
1 – Enable | ||||||
109 | Uint8 | 10 | 1 | 15 | 0 – Undefined | GNSS source |
1 – Beidou only | ||||||
2 – Glonass only | ||||||
3 – Glonass and Beidou not allowed | ||||||
4 – Galileo only | ||||||
5 – Galileo and Beidou | ||||||
6 – Galileo and Glonass | ||||||
7 – Galileo, Glonass and Beidou not allowed | ||||||
8 – Gps only | ||||||
9 – Gps and Beidou | ||||||
10 – Gps and Glonass | ||||||
11 – Gps, Glonass and Beidou not allowed | ||||||
12 – Gps and Galileo | ||||||
13 – Gps, Galileo and Beidou | ||||||
14 – Gps, Galileo and Glonass | ||||||
15 – Gps, Galileo, Glonass and Beidou and not allowed | ||||||
110 | Uint8 | 0 | 0 | 1 | 0 – On need | Battery charge mode| |
1 – After ignition on |
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
102 | Uint8 | 2 | 0 | 2 | 0 – Disable | Sleep settings |
1 – Gps sleep | ||||||
2 – Deep sleep | ||||||
103 | Uint16 | 1 | 1 | 3000 | Minutes | Timeout |
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
101 | Uint8 | 0 | 0 | 2 | 0 – Power voltage | Ignition settings |
1 – Din 1 | ||||||
2 – Accelerometer | ||||||
104 | Uint16 | 30000 | 0 | 30000 | mV | High voltage |
105 | Uint16 | 13200 | 0 | 29999 | mV | Low voltage |
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
900 | Uint8 | 1 | 0 | 3 | 0 – Gps only | Synchronization settings |
1 – NITZ and NTP | ||||||
2 – NTP | ||||||
3 – NITZ | ||||||
901 | Uint8 | 0 | 0 | 24 | Hours | NTP Resync |
902 | Char | "avl1.teltonika.lt" | 0 | 55 | String | NTP server 1 |
903 | Char | "pool.ntp.org" | 0 | 55 | String | NTP server 2 |
GPRS parameters
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1000 | Uint32 | 5 | 0 | 259200 | Seconds | Open link timeout |
1001 | Uint16 | 30 | 5 | 300 | Seconds | Response timeout |
1002 | Uint8 | 0 | 0 | 1 | 0 – Newest | Sort by |
1 – Oldest |
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
2000 | Uint8 | 1 | 0 | 1 | 0 – Disable | GPRS context |
1 – Enable | ||||||
2001 | Char | "" | 0 | 32 | String | APN |
2002 | Char | "" | 0 | 32 | String | APN username |
2003 | Char | "" | 0 | 32 | String | APN password |
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
2004 | Char | "" | 0 | 55 | String | Domain |
2005 | Uint16 | 0 | 0 | 65535 | Number | Port |
2006 | Uint8 | 1 | 0 | 1 | 0 – TCP | Protocol |
1 – UDP |
SMS/Call settings
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
3000 | Uint8 | 0 | 0 | 1 | 0 – Disable | Allow SMS data sending |
1 – Enable | ||||||
3001 | Char | "" | 0 | 16 | String | Data Send Number |
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
3003 | Char | "" | 0 | 5 | String | Login |
3004 | Char | "" | 0 | 5 | String | Password |
3006 | Uint16 | UTC+00:00 | UTC-12:00 | UTC+13:00 | Time zone | SMS event Time Zone |
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
3005 | Uint8 | 0 | 0 | 4 | 0 – Do nothing | Incoming call action |
1 – Hangup | ||||||
2 – Report position | ||||||
3 – Spy call | ||||||
4 – Auto answer |
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
3007 | Uint8 | 0 | 0 | 3 | 0 – Disable | Outgoing call trigger |
1 – DIN 1 | ||||||
2 – Crash event | ||||||
3 – DIN1 and Crash event | ||||||
3008 | Uint8 | 0 | 0 | 10 | GSM number | GSM number index |
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
4000-4009 | Char | "" | 0 | 16 | String | Authorized number |
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
6000-6009 | Char | "" | 0 | 16 | String | Predefined number |
GSM operators
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
5000-5049 | Uint32 | 0 | 0 | 999999 | Number | Operator code |
Data acquisition mode parameters
Home Network GSM operator code "Vehicle on STOP" parameters
Parameted ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10000 | Uint16 | 3600 | 0 | 65535 | Min Period |
10004 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10055 | Uint16 | 120 | 0 | 65535 | Send Period |
Home Network GSM operator code "Vehicle MOVING" parameters
Parameted ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10050 | Uint16 | 300 | 0 | 65535 | Min Period |
10051 | Uint16 | 100 | 0 | 65535 | Min Distance |
10052 | Uint8 | 10 | 0 | 180 | Min Angle |
10053 | Uint8 | 10 | 0 | 100 | Min Speed Delta |
10054 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10055 | Uint16 | 120 | 0 | 65535 | Send Period |
Roaming Network GSM operator code "Vehicle on STOP" parameters
Parameted ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10100 | Uint16 | 3600 | 0 | 65535 | Min Period |
10104 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10105 | Uint16 | 0 | 0 | 65535 | Send Period |
Roaming Network GSM operator code "Vehicle MOVING" parameters
Parameted ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10150 | Uint16 | 300 | 0 | 65535 | Min Period |
10151 | Uint16 | 100 | 0 | 65535 | Min Distance |
10152 | Uint8 | 10 | 0 | 180 | Min Angle |
10153 | Uint8 | 10 | 0 | 100 | Min Speed Delta |
10154 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10155 | Uint16 | 0 | 0 | 65535 | Send Period |
Unknown Network GSM operator code "Vehicle on STOP" parameters
Parameted ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10200 | Uint16 | 3600 | 0 | 65535 | Min Period |
10204 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10205 | Uint16 | 120 | 0 | 65535 | Send Period |
Unknown Network GSM operator code "Vehicle MOVING" parameters
Parameted ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10250 | Uint16 | 300 | 0 | 65535 | Min Period |
10251 | Uint16 | 100 | 0 | 65535 | Min Distance |
10252 | Uint8 | 10 | 0 | 180 | Min Angle |
10253 | Uint8 | 10 | 0 | 100 | Min Speed Delta |
10254 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10255 | Uint16 | 0 | 0 | 65535 | Send Period |
Features parameters
Green driving parameters
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
11000 | Uint8 | 0 | 0 | 3 | 0 – Disable | Scenario settings |
1 – Low priority | ||||||
2 – High priority | ||||||
3 – Panic priority | ||||||
11004 | Uint8 | 25 | 25 | 85 | mG | Max acceleration |
11005 | Uint8 | 35 | 25 | 85 | mG | Max braking |
11006 | Uint8 | 30 | 10 | 100 | mG | Max cornering |
11007 | Uint8 | 0 | 0 | 1 | 0 – GPS | Source |
1 – Accelerometer | ||||||
11008 | uint8 | 0 | 0 | 1 | Enable/Disable | Duration |
11003 | Uint8 | 0 | 0 | 1 | 0 – None | Output control |
1 – DOUT 1 | ||||||
11001 | Int32 | 200 | 0 | 2147483647 | Milliseconds | DOUT ON duration |
11002 | Int32 | 200 | 0 | 2147483647 | Milliseconds | DOUT OFF duration |
7034 | Uint8 | 0 | 0 | 10 | Phone number | Send SMS to |
8034 | String | "Green Driving" | 0 | 160 | Text | Sms text |
Overspeeding scenario parameters
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
11100 | Uint8 | 0 | 0 | 3 | 0 – Disable | Scenario settings |
1 – Low priority | ||||||
2 – High priority | ||||||
3 – Panic priority | ||||||
11104 | Uint16 | 90 | 0 | 260 | km/h | Max speed |
11103 | Uint8 | 0 | 0 | 1 | 0 – None | Output control |
1 – DOUT 1 | ||||||
11101 | Int32 | 200 | 0 | 2147483647 | Milliseconds | DOUT ON duration |
11102 | Int32 | 200 | 0 | 2147483647 | Milliseconds | DOUT OFF duration |
7032 | Uint8 | 0 | 0 | 10 | Phone number | Send SMS to |
8032 | String | "Overspeeding" | 0 | 160 | Text | Sms text |
Jamming scenario parameters
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
11300 | Uint8 | 0 | 0 | 3 | 0 – Disable | Scenario settings |
1 – Low priority | ||||||
2 – High priority | ||||||
3 – Panic priority | ||||||
11303 | Uint8 | 1 | 0 | 1 | 0 – Disable | Eventual records |
1 – Enable | ||||||
11304 | Uint8 | 0 | 0 | 1 | 0 – None | Output control |
1 – DOUT 1 | ||||||
11301 | Int32 | 200 | 0 | 2147483647 | Milliseconds | DOUT ON duration |
11302 | Int32 | 200 | 0 | 2147483647 | Milliseconds | DOUT OFF duration |
11305 | Uint16 | 60 | 0 | 65535 | Seconds | Timeout |
Immobilizer scenario parameters
Trip scenario parameters
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
11800 | Uint8 | 0 | 0 | 3 | 0 – Disable | Scenario settings |
1 – Low priority | ||||||
2 – High priority | ||||||
3 – Panic priority | ||||||
11801 | Uint8 | 1 | 0 | 1 | 0 – Disable | Eventual records |
1 – Enable | ||||||
11802 | Uint8 | 0 | 0 | 1 | 0 – Continuous | Mode |
1 – Between records | ||||||
11803 | Uint8 | 5 | 0 | 255 | km/h | Start speed |
11804 | Uint16 | 60 | 0 | 65535 | Seconds | Ignition off timeout |
7031 | Uint8 | 0 | 0 | 10 | Phone number | Send SMS to |
8031 | String | "Trip" | 0 | 160 | Text | Sms text |
DOUT control via call scenario parameters
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
12000 | Uint8 | 0 | 0 | 1 | 0 – None | Digital Output control |
1 – DOUT 1 | ||||||
12001 | Uint8 | 0 | 0 | 1 | 0 – None | DOUT deactivation |
1 – DIN 1 | ||||||
12002 | Int32 | 5 | 0 | 2147483647 | Seconds | Duration timeout |
iButton read notification
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
11704 | Uint8_t | 0 | 0 | 1 | 0 - Disabled | Dout control |
1 - Enabled | ||||||
11705 | Uint16_t | 200 | 100 | 50000 | ms | Dout duration |
11706 | Uint8_t | 0 | 0 | 1 | 0 - Disabled | iButton notification list |
1 - Enabled | ||||||
11707 | Uint8_t | 0 | 0 | 1 | 0 - Disabled | Depend on ignition |
1 - Enabled |
AutoGeofencing scenario parameters
Manual Geofence
First Geozone parameters
Other Geozones
GPS Fuel counter
Accelerometer features
Unplug Detection
Towing Detection
Crash Detection
Excessive Idling
Parameted ID | Parameter Type | Default value | Value range | Value | Parameter name | ||
---|---|---|---|---|---|---|---|
Min | Max | ||||||
11200 | Uint8 | 0 | 0 | 3 | 0 – Disable | Scenario settings | |
1 – Low priority | |||||||
2 – High priority | |||||||
3 – Panic priority | |||||||
11203 | Uint8 | 1 | 0 | 1 | 0 – Disable | Eventual records | |
1 – Enable | |||||||
11205 | Uint8 | 5 | 0 | 255 | Seconds | Time to stoped | |
11206 | Uint8 | 2 | 0 | 255 | Seconds | Time to moving | |
11204 | Uint8 | 0 | 0 | 1 | 0 – None | Output control | |
1 – DOUT 1 | |||||||
11201 | Int32 | 200 | 0 | 2147483647 | Milliseconds | DOUT ON duration | |
11202 | Int32 | 200 | 0 | 2147483647 | Milliseconds | DOUT OFF duration | |
7033 | Uint8 | 0 | 0 | 10 | Phone number | Send SMS to | |