Difference between revisions of "Template:FMB SMS/Call settings"

From Wiki Knowledge Base | Teltonika GPS
Line 1: Line 1:
Essential fields in ''SMS'' part is ''Login'' and ''Password''. The login and password are used with every SMS sent to FMB120. If login and password are not set, in every SMS sent to FMB120 device two spaces before command have to be used (<space><space><command>).<br/>Command structure with set login and password:<br/><login><space><password><space><command>, for example: "asd 123 getgps"<br/>Phone numbers have to be written in international standard, using "+" is optional but not necessary (in both cases number will be recognized, but when number is without "+" symbol, IDD Prefix will not be generated, which depends on location of the phone). If no numbers are entered, configuration and sending commands over SMS are allowed from all GSM numbers.<br/>SMS data sending settings allow sending AVL data using binary SMS. AVL data will be sent by SMS only when there is no GPRS connection. This setting does not affect replies to SMS request messages – answers are always sent back to the sender's telephone number.
+
Essential fields in ''SMS/Call settings'' are ''Login'' and ''Password''. The login and password are used with every SMS sent to FMB120. If login and password are not set, in every SMS sent to FMB120 device two spaces before command have to be used (<space><space><command>).<br/>Command structure with set login and password:<br/><login><space><password><space><command>, for example: "asd 123 getgps"<br/>Phone numbers have to be written in international standard, using "+" is optional but not necessary (in both cases number will be recognized, but when number is without "+" symbol, IDD Prefix will not be generated, which depends on location of the phone). If no numbers are entered, configuration and sending commands over SMS are allowed from all GSM numbers.<br/>SMS data sending settings allow sending AVL data using binary SMS. AVL data will be sent by SMS only when there is no GPRS connection. This setting does not affect replies to SMS request messages – answers are always sent back to the sender's telephone number.
 
[[Image:Fmb120_smscall_settings.png|800px|centre]]
 
[[Image:Fmb120_smscall_settings.png|800px|centre]]
  

Revision as of 13:27, 25 April 2018

Essential fields in SMS/Call settings are Login and Password. The login and password are used with every SMS sent to FMB120. If login and password are not set, in every SMS sent to FMB120 device two spaces before command have to be used (<space><space><command>).
Command structure with set login and password:
<login><space><password><space><command>, for example: "asd 123 getgps"
Phone numbers have to be written in international standard, using "+" is optional but not necessary (in both cases number will be recognized, but when number is without "+" symbol, IDD Prefix will not be generated, which depends on location of the phone). If no numbers are entered, configuration and sending commands over SMS are allowed from all GSM numbers.
SMS data sending settings allow sending AVL data using binary SMS. AVL data will be sent by SMS only when there is no GPRS connection. This setting does not affect replies to SMS request messages – answers are always sent back to the sender's telephone number.

Fmb120 smscall settings.png

Incoming call settings parameter defines device action during incoming call:

  • Do Nothing.
  • Hang-up – automatically hang up incoming call.
  • Report Position – Report position to calling number via SMS.
  • Auto Answer (HF) – Auto answer incoming call if hands-free device is connected. If hands-free device is not connected, then incoming call will be hung up.

When FMB120 is connected to a hands-free headset, it can call to user defined GSM numbers.

Fmb120 handsfree.png

Outgoing Call Trigger parameter determines which event will trigger a call. FMB120 supports eight call triggers:

  • None selected – disables call trigger functionality.
  • DIN1 – first digital input event triggers call to user selected GSM number.
  • Crash Event – crash event triggers call to user selected GSM number.
  • DIN1 and Crash Event – both events trigger call to user selected GSM number.
  • DIN2 – second digital input event triggers call to user selected GSM number.
  • DIN1 and DIN2 Event – both events trigger call to user selected GSM number.
  • DIN2 and Crash Event – both events trigger call to user selected GSM number.
  • DIN1, DIN2 and Crash Event – all events trigger call to user selected GSM number.

FMB120 works in synchronized GPS time which is UTC+0, with this option customer can configure the time zone and get SMS messages with correct time.

Bw nb.png Please do not set Data Send Number to some cell phone number, because it will not understand binary SMS. When sending a binary SMS to a phone number, which is a server phone number, the server can interpret and understand binary code, so the data can be read and you can view it on the server.
Bw nb.png SMS login and password and authorized numbers list are used to protect FMB120 module from unauthorized access. Module accepts messages only from a list of authorized numbers and with proper module login and password. Phone numbers have to be written in international standard using "+" or without using it (in both cases the number will be recognized). If no authorized numbers are entered, module accepts messages from all numbers.