Template:FMB Auto Geofence settings: Difference between revisions
Atabasnikov (talk | contribs) mNo edit summary |
Atabasnikov (talk | contribs) mNo edit summary |
||
Line 1: | Line 1: | ||
{{{pic_autogeofence|[[Image:Fmb120_autogeofence.png|300px|right]]}}} | {{{pic_autogeofence|[[Image:Fmb120_autogeofence.png|300px|right]]}}} | ||
AutoGeofence is based on the last known position after the movement has stopped. You can be notified using this function if your car is taken away. The shape and size of Geofence zones are set by parameters. It is possible to state whether entering or leaving the geofence triggers an asynchronous message. | ''AutoGeofence'' is based on the last known position after the movement has stopped. You can be notified using this function if your car is taken away. The shape and size of Geofence zones are set by parameters. It is possible to state whether entering or leaving the geofence triggers an asynchronous message. | ||
AutoGeofencing options can be configured by following parameters as depicted in the right hand side figure:<br/>Activation timeout defines the delay between the creation of AutoGeofence within set ''Radius'' value around vehicle's most recent position and when the ignition is off. Note that AutoGeofencing does not require entering coordinates, instead it requires GPS visibility. AutoGeofence can be deactivated by: | AutoGeofencing options can be configured by following parameters as depicted in the right hand side figure:<br/>Activation timeout defines the delay between the creation of AutoGeofence within set ''Radius'' value around vehicle's most recent position and when the ignition is off. Note that AutoGeofencing does not require entering coordinates, instead it requires GPS visibility. AutoGeofence can be deactivated by: | ||
{{{text_din|* <span style=color:#F6A83E>Digital Input 1</span> – If DIN1 voltage becomes equal or higher than 6.9 V. | {{{text_din|* <span style=color:#F6A83E>Digital Input 1</span> – If DIN1 voltage becomes equal or higher than 6.9 V. | ||
Line 9: | Line 9: | ||
* <span style=color:#F6A83E>Power Voltage</span> – If power voltage becomes higher than low voltage level (defined in Ignition settings). | * <span style=color:#F6A83E>Power Voltage</span> – If power voltage becomes higher than low voltage level (defined in Ignition settings). | ||
* <span style=color:#F6A83E>Engine RPM</span> – If engine RPM value becomes higher than 0.<br/> | * <span style=color:#F6A83E>Engine RPM</span> – If engine RPM value becomes higher than 0.<br/> | ||
Event generation can take place on Geofence <span style=color:#F6A83E>Entrance</span>, <span style=color:#F6A83E>Exit</span> or <span style=color:#F6A83E>On Both</span>. ''Eventual Records'' is used to enable or disable Eventual Records functionality. | Event generation can take place on Geofence <span style=color:#F6A83E>Entrance</span>, <span style=color:#F6A83E>Exit</span> or <span style=color:#F6A83E>On Both</span>. ''Eventual Records'' is used to enable or disable ''Eventual Records'' functionality. |
Revision as of 14:26, 27 April 2018
AutoGeofence is based on the last known position after the movement has stopped. You can be notified using this function if your car is taken away. The shape and size of Geofence zones are set by parameters. It is possible to state whether entering or leaving the geofence triggers an asynchronous message.
AutoGeofencing options can be configured by following parameters as depicted in the right hand side figure:
Activation timeout defines the delay between the creation of AutoGeofence within set Radius value around vehicle's most recent position and when the ignition is off. Note that AutoGeofencing does not require entering coordinates, instead it requires GPS visibility. AutoGeofence can be deactivated by:
- Digital Input 1 – If DIN1 voltage becomes equal or higher than 6.9 V.
- Digital Input 2 – If DIN2 voltage becomes equal or higher than 2.1 V.
- Digital Input 3 – If DIN3 voltage becomes equal or higher than 3.5 V.
- iButton – If authorized iButton is attached.
- Power Voltage – If power voltage becomes higher than low voltage level (defined in Ignition settings).
- Engine RPM – If engine RPM value becomes higher than 0.
Event generation can take place on Geofence Entrance, Exit or On Both. Eventual Records is used to enable or disable Eventual Records functionality.