Difference between revisions of "Template:FTXXXX Device Family Parameter list"
From Wiki Knowledge Base | Teltonika GPS
Line 854: | Line 854: | ||
! rowspan="2" style="width: 150px; background: black; color: white;" |'''Value''' | ! rowspan="2" style="width: 150px; background: black; color: white;" |'''Value''' | ||
! rowspan="2" style="width: 150px; background: black; color: white;" |'''Parameter name''' | ! rowspan="2" style="width: 150px; background: black; color: white;" |'''Parameter name''' | ||
+ | |- | ||
+ | ! style="width: 75px; background: black; color: white;" |Min | ||
+ | ! style="width: 75px; background: black; color: white;" |Max | ||
|- | |- | ||
! rowspan="3" style="text-align: center; vertical-align: center;" |107 | ! rowspan="3" style="text-align: center; vertical-align: center;" |107 | ||
Line 878: | Line 881: | ||
| style="text-align: center; vertical-align: center;" |1 – Oldest | | style="text-align: center; vertical-align: center;" |1 – Oldest | ||
|- | |- | ||
− | ! rowspan=" | + | ! rowspan="2" style="{{{hide_table_tmt250|}}}text-align: center; vertical-align: center;" |113 |
− | | rowspan=" | + | | rowspan="2" style="{{{hide_table_tmt250|}}}text-align: center; vertical-align: center;" |Uint8 |
− | | rowspan=" | + | | rowspan="2" style="{{{hide_table_tmt250|}}}text-align: center; vertical-align: center;" |1 |
− | | rowspan=" | + | | rowspan="2" style="{{{hide_table_tmt250|}}}text-align: center; vertical-align: center;" |1 |
− | | rowspan=" | + | | rowspan="2" style="{{{hide_table_tmt250|}}}text-align: center; vertical-align: center;" |1 |
− | | rowspan=" | + | | rowspan="2" style="{{{hide_table_tmt250|}}}text-align: center; vertical-align: center;" |1 – Codec 8 Extended |
|- | |- | ||
− | | style="{{{hide_table_tmt250|}}}text-align: center; vertical-align: center;" | | + | | style="{{{hide_table_tmt250|}}}text-align: center; vertical-align: center;" |Data Protocol |
|- | |- | ||
|} | |} |
Revision as of 10:36, 29 April 2024
System parameters
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
138 | Uint8 | 0 | 0 | 8 | 1 – Ignition | Movement source |
2 – Accelerometer | ||||||
4 – GNSS | ||||||
8 - CAN Speed | ||||||
133 | Uint8 | 0 | 0 | 1 | 0 – GNSS | Speed Source |
1 – OBD / CAN | ||||||
106 | Uint8 | 1 | 0 | 1 | 0 – Disable | Static navigation |
1 – Enable | ||||||
112 | Uint8 | 1 | 0 | 3 | 1 – Movement | Static navigation source |
2 – Ignition | ||||||
3 – Movement and Ignition | ||||||
107 | Uint8 | 2 | 0 | 2 | 0 – After Position Fix | Send/Save records without TS |
1 – Always | ||||||
2 – After Time Sync | ||||||
108 | Uint8 | 1 | 0 | 1 | 0 – Disable | LED Indication |
1 – Enable | ||||||
109 | Uint8 | 10 | 1 | 15 | 0 – Undefined | GNSS source |
1 – Beidou only | ||||||
2 – Glonass only | ||||||
3 – Glonass and Beidou not allowed | ||||||
4 – Galileo only | ||||||
5 – Galileo and Beidou | ||||||
6 – Galileo and Glonass | ||||||
7 – Galileo, Glonass and Beidou not allowed | ||||||
8 – Gps only | ||||||
9 – Gps and Beidou | ||||||
10 – Gps and Glonass | ||||||
11 – Gps, Glonass and Beidou not allowed | ||||||
12 – Gps and Galileo | ||||||
13 – Gps, Galileo and Beidou | ||||||
14 – Gps, Galileo and Glonass | ||||||
15 – Gps, Galileo, Glonass and Beidou and not allowed | ||||||
110 | Uint8 | 0 | 0 | 1 | 0 – On need | Battery charge mode |
1 – After ignition on | ||||||
113 | Uint8 | 0 | 0 | 1 | 0 – Codec 8 | Data Protocol |
1 – Codec 8 Extended | ||||||
135 | Uint8 | 0 | 0 | 1 | 0 – DIN2/AIN1 | Input mode |
1 – Ground Sense |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
102 | Uint8 | 2 | 0 | 4 | 0 – Disable | Sleep settings |
1 – GPS sleep | ||||||
2 – Deep sleep | ||||||
3 – Online Deep sleep | ||||||
4 – Ultra Deep sleep | ||||||
6 – Power Off sleep (only for FMB965) | ||||||
103 | Uint16 | 1 | 1 | 3000 | Minutes | Timeout |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
101 | Uint8 | 4 | 1 | 14 | 1 – DIN 1 | Ignition settings |
2 – Accelerometer | ||||||
3 – Digital Input or Accelerometer | ||||||
4 - Power Voltage | ||||||
5 - Digital Input or Power Voltage | ||||||
6 - Accelerometer or Power Voltage | ||||||
7 – Digital Input, Accelerometer, or Power Voltage | ||||||
8 - Engine RPM | ||||||
9 - Digital Input or Engine RPM | ||||||
10 - Accelerometer or Engine RPM | ||||||
11 - Digital Input, Accelerometer or Engine RPM | ||||||
12 - Power Voltage or Engine RPM | ||||||
13 - Digital Input, Power Voltage or Engine RPM | ||||||
14 - Accelerometer, Power Voltage or Engine RPM | ||||||
104 | Uint16 | 30000 | 0 | 30000 | mV | High voltage |
105 | Uint16 | 13200 | 0 | 29999 | mV | Low voltage |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
19001 | Uint16 | 5 | 1 | 60 | Seconds | Movement Start Delay |
19002 | Uint16 | 60 | 5 | 300 | Seconds | Movement Stop Delay |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
900 | Uint8 | 1 | 0 | 3 | 0 – Gps only | Synchronization settings |
1 – NITZ and NTP | ||||||
2 – NTP | ||||||
3 – NITZ | ||||||
901 | Uint8 | 0 | 0 | 24 | Hours | NTP Resync |
902 | Char | "avl1.teltonika.lt" | 0 | 55 | String | NTP server 1 |
903 | Char | "pool.ntp.org" | 0 | 55 | String | NTP server 2 |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
169 | Uint8 | 2 | 0 | 2 | 0 – Disabled | Accelerometer Auto Calibration |
1 – Once | ||||||
2 – Continuous | ||||||
170 | Uint8 | 1 | 0 | 1 | 0 Disabled | Gravity Filter |
1 Enabled |
GPRS parameters
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1000 | Uint32 | 300 | 30 | 259200 | Seconds | Open link timeout |
1001 | Uint16 | 30 | 5 | 300 | Seconds | Response timeout |
1002 | Uint8 | 0 | 0 | 1 | 0 – Newest | Sort by |
1 – Oldest | ||||||
1003 | Uint16 | 0 | 0 | 300 | Seconds | Network ping timeout |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
2000 | Uint8 | 1 | 0 | 1 | 0 – Disable | GPRS context |
1 – Enable | ||||||
2001 | Char | "" | 0 | 32 | String | APN |
2002 | Char | "" | 0 | 32 | String | APN username |
2003 | Char | "" | 0 | 32 | String | APN password |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
2004 | Char | "" | 0 | 55 | String | Domain |
2005 | Uint16 | 0 | 0 | 65535 | Number | Port |
2006 | Uint8 | 1 | 0 | 1 | 0 – TCP | Protocol |
1 – UDP |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
2010 | Uint8 | 0 | 0 | 3 | 0 - Disable | Backup Server Mode |
1 - Backup | ||||||
2 - Duplicate | ||||||
3 - EGTS | ||||||
2007 | Char | "" | 0 | 55 | String | Backup Server Domain |
2008 | Uint16 | 0 | 0 | 65535 | Number | Backup Server Port |
2009 | Uint8 | 0 | 0 | 1 | 0 - TCP | Backup Server Protocol |
1 - UDP |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
13003 | Uint8 | 1 | 0 | 1 | 0 - Disable | FOTA WEB Status |
1 – Enable | ||||||
13000 | Char | fm.teltonika.lt | 0 | 55 | String | FOTA WEB Domain |
13001 | Uint16 | 5000 | 0 | 65535 | Number | FOTA WEB Port |
13002 | Uint16 | 720 | 30 | 65535 | Number | FOTA WEB Period |
SMS/Call settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
3000 | Uint8 | 0 | 0 | 1 | 0 – Disable | Allow SMS data sending |
1 – Enable | ||||||
3001 | Char | "" | 0 | 16 | String | Data Send Number |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
3003 | Char | "" | 0 | 5 | String | Login |
3004 | Char | "" | 0 | 5 | String | Password |
3006 | Uint16 | UTC+00:00 | UTC-12:00 | UTC+13:00 | Time zone | SMS event Time Zone |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
3005 | Uint8 | 0 | 0 | 4 | 0 – Do nothing | Incoming call action |
1 – Hangup | ||||||
2 – Report position | ||||||
3 – Spy call | ||||||
4 – Auto answer |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
3007 | Uint8 | 0 | 0 | 7 (3 for FMB125) | 0 – Disable | Outgoing call trigger |
1 – DIN1 | ||||||
2 – Crash event | ||||||
3 – DIN1 and Crash event | ||||||
4 – DIN2 | ||||||
5 – DIN1 and DIN2 | ||||||
6 – DIN2 and Crash event | ||||||
7 – DIN1, DIN2 and Crash event | ||||||
3008 | Uint8 | 0 | 0 | 10 | GSM number | GSM number index |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
4000-4199 | Char | "" | 0 | 16 | String | Authorized number |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
6000-6009 | Char | "" | 0 | 16 | String | Predefined number |
GSM operators
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
5000-5049 | Uint32 | 0 | 0 | 999999 | Number | SIM1 roaming operator list |
9500-9549 | Uint32 | 0 | 0 | 999999 | Number | SIM2 roaming/home operator list |
5500-5549 | Uint32 | 0 | 0 | 999999 | Number | Operator blacklist |
Tracking settings
Records settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
107 | Uint8 | 2 | 0 | 2 | 0 – After position fix | Saving sending mode |
1 – Always | ||||||
2 – After time sync | ||||||
1002 | Uint8 | 0 | 0 | 1 | 0 – Newest | Sort by |
1 – Oldest | ||||||
113 | Uint8 | 1 | 1 | 1 | 1 – Codec 8 Extended | |
Data Protocol |
Home Network GSM operator code "Vehicle on STOP" parameters
Parameter ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10000 | Uint16 | 3600 | 0 | 65535 | Min Period |
10004 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10005 | Uint16 | 120 | 0 | 65535 | Send Period |
Home Network GSM operator code "Vehicle MOVING" parameters
Parameter ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10050 | Uint16 | 300 | 0 | 65535 | Min Period |
10051 | Uint16 | 100 | 0 | 65535 | Min Distance |
10052 | Uint8 | 10 | 0 | 180 | Min Angle |
10053 | Uint8 | 10 | 0 | 100 | Min Speed Delta |
10054 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10055 | Uint16 | 120 | 0 | 65535 | Send Period |
Roaming Network GSM operator code "Vehicle on STOP" parameters
Parameter ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10100 | Uint16 | 3600 | 0 | 65535 | Min Period |
10104 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10105 | Uint16 | 0 | 0 | 65535 | Send Period |
Roaming Network GSM operator code "Vehicle MOVING" parameters
Parameter ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10150 | Uint16 | 300 | 0 | 65535 | Min Period |
10151 | Uint16 | 100 | 0 | 65535 | Min Distance |
10152 | Uint8 | 10 | 0 | 180 | Min Angle |
10153 | Uint8 | 10 | 0 | 100 | Min Speed Delta |
10154 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10155 | Uint16 | 0 | 0 | 65535 | Send Period |
Unknown Network GSM operator code "Vehicle on STOP" parameters
Parameter ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10200 | Uint16 | 3600 | 0 | 65535 | Min Period |
10204 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10205 | Uint16 | 120 | 0 | 65535 | Send Period |
Unknown Network GSM operator code "Vehicle MOVING" parameters
Parameter ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10250 | Uint16 | 300 | 0 | 65535 | Min Period |
10251 | Uint16 | 100 | 0 | 65535 | Min Distance |
10252 | Uint8 | 10 | 0 | 180 | Min Angle |
10253 | Uint8 | 10 | 0 | 100 | Min Speed Delta |
10254 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10255 | Uint16 | 0 | 0 | 65535 | Send Period |
Features
Driving behavior
Overspeeding
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1025500 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority | ||||||
11104 | Uint16 | 90 | 0 | 260 | km/h | Max speed |
Trip
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1025000 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority | ||||||
11803 | Uint8 | 5 | 0 | 255 | km/h | Start speed |
11804 | Uint16 | 60 | 0 | 65535 | Seconds | Ignition OFF timeout |
Odometer
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1001600 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority | ||||||
11807 | Uint32 | 0 | 0 | 4294967 | Kilometer | Odometer value |
Vehicle protection
Unplug Detection
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1025200 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority |
Other features
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
106 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority |
Digital output overcurrent recovery
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
350 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority |
|}