| style="text-align: center; vertical-align: center;" |Predefined number
 
| style="text-align: center; vertical-align: center;" |Predefined number
 
|-
 
|-
|}
 
 
==GSM operators==
 
{| class="wikitable"
 
|+
 
! rowspan="2" style="width: 150px; background: black; color: white;" |'''Parameter ID'''
 
! rowspan="2" style="width: 150px; background: black; color: white;" |'''Parameter Type'''
 
! rowspan="2" style="width: 150px; background: black; color: white;" |'''Default value'''
 
! colspan="2" style="width: 150px; background: black; color: white;" |'''Value range'''
 
! rowspan="2" style="width: 150px; background: black; color: white;" |'''Value'''
 
! rowspan="2" style="width: 150px; background: black; color: white;" |'''Parameter name'''
 
|-
 
! style="width: 75px; background: black; color: white;" |Min
 
! style="width: 75px; background: black; color: white;" |Max
 
|-
 
! style="text-align: center; vertical-align: center;" |5000-5049
 
| style="text-align: center; vertical-align: center;" |Uint32
 
| style="text-align: center; vertical-align: center;" |0
 
| style="text-align: center; vertical-align: center;" |0
 
| style="text-align: center; vertical-align: center;" |999999
 
| style="text-align: center; vertical-align: center;" |Number
 
| style="text-align: center; vertical-align: center;" |SIM1 roaming operator list
 
|-
 
! style="text-align: center; vertical-align: center;" |9500-9549
 
| style="text-align: center; vertical-align: center;" |Uint32
 
| style="text-align: center; vertical-align: center;" |0
 
| style="text-align: center; vertical-align: center;" |0
 
| style="text-align: center; vertical-align: center;" |999999
 
| style="text-align: center; vertical-align: center;" |Number
 
| style="text-align: center; vertical-align: center;" |SIM2 roaming/home operator list
 
|-
 
! style="text-align: center; vertical-align: center;" |5500-5549
 
| style="text-align: center; vertical-align: center;" |Uint32
 
| style="text-align: center; vertical-align: center;" |0
 
| style="text-align: center; vertical-align: center;" |0
 
| style="text-align: center; vertical-align: center;" |999999
 
| style="text-align: center; vertical-align: center;" |Number
 
| style="text-align: center; vertical-align: center;" |Operator blacklist
 
|-
 
 
|}
 
|}
  

Revision as of 10:45, 29 April 2024

System parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
138 Uint8 0 0 8 1 – Ignition Movement source
2 – Accelerometer
4 – GNSS
8 - CAN Speed
133 Uint8 0 0 1 0 – GNSS Speed Source
1 – OBD / CAN
106 Uint8 1 0 1 0 – Disable Static navigation
1 – Enable
112 Uint8 1 0 3 1 – Movement Static navigation source
2 – Ignition
3 – Movement and Ignition
107 Uint8 2 0 2 0 – After Position Fix Send/Save records without TS
1 – Always
2 – After Time Sync
108 Uint8 1 0 1 0 – Disable LED Indication
1 – Enable
109 Uint8 10 1 15 0 – Undefined GNSS source
1 – Beidou only
2 – Glonass only
3 – Glonass and Beidou not allowed
4 – Galileo only
5 – Galileo and Beidou
6 – Galileo and Glonass
7 – Galileo, Glonass and Beidou not allowed
8 – Gps only
9 – Gps and Beidou
10 – Gps and Glonass
11 – Gps, Glonass and Beidou not allowed
12 – Gps and Galileo
13 – Gps, Galileo and Beidou
14 – Gps, Galileo and Glonass
15 – Gps, Galileo, Glonass and Beidou and not allowed
110 Uint8 0 0 1 0 – On need Battery charge mode
1 – After ignition on
113 Uint8 0 0 1 0 – Codec 8 Data Protocol
1 – Codec 8 Extended
135 Uint8 0 0 1 0 – DIN2/AIN1 Input mode
1 – Ground Sense
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
102 Uint8 2 0 4 0 – Disable Sleep settings
1 – GPS sleep
2 – Deep sleep
3 – Online Deep sleep
4 – Ultra Deep sleep
6 – Power Off sleep (only for FMB965)
103 Uint16 1 1 3000 Minutes Timeout


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
101 Uint8 4 1 14 1 – DIN 1 Ignition settings
2 – Accelerometer
3 – Digital Input or Accelerometer
4 - Power Voltage
5 - Digital Input or Power Voltage
6 - Accelerometer or Power Voltage
7 – Digital Input, Accelerometer, or Power Voltage
8 - Engine RPM
9 - Digital Input or Engine RPM
10 - Accelerometer or Engine RPM
11 - Digital Input, Accelerometer or Engine RPM
12 - Power Voltage or Engine RPM
13 - Digital Input, Power Voltage or Engine RPM
14 - Accelerometer, Power Voltage or Engine RPM
104 Uint16 30000 0 30000 mV High voltage
105 Uint16 13200 0 29999 mV Low voltage
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
19001 Uint16 5 1 60 Seconds Movement Start Delay
19002 Uint16 60 5 300 Seconds Movement Stop Delay
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
900 Uint8 1 0 3 0 – Gps only Synchronization settings
1 – NITZ and NTP
2 – NTP
3 – NITZ
901 Uint8 0 0 24 Hours NTP Resync
902 Char "avl1.teltonika.lt" 0 55 String NTP server 1
903 Char "pool.ntp.org" 0 55 String NTP server 2
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
169 Uint8 2 0 2 0 – Disabled Accelerometer Auto Calibration
1 – Once
2 – Continuous
170 Uint8 1 0 1 0 Disabled Gravity Filter
1 Enabled

GPRS parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1000 Uint32 300 30 259200 Seconds Open link timeout
1001 Uint16 30 5 300 Seconds Response timeout
1002 Uint8 0 0 1 0 – Newest Sort by
1 – Oldest
1003 Uint16 0 0 300 Seconds Network ping timeout
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2000 Uint8 1 0 1 0 – Disable GPRS context
1 – Enable
2001 Char "" 0 32 String APN
2002 Char "" 0 32 String APN username
2003 Char "" 0 32 String APN password
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2004 Char "" 0 55 String Domain
2005 Uint16 0 0 65535 Number Port
2006 Uint8 1 0 1 0 – TCP Protocol
1 – UDP
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2010 Uint8 0 0 3 0 - Disable Backup Server Mode
1 - Backup
2 - Duplicate
3 - EGTS
2007 Char "" 0 55 String Backup Server Domain
2008 Uint16 0 0 65535 Number Backup Server Port
2009 Uint8 0 0 1 0 - TCP Backup Server Protocol
1 - UDP
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13003 Uint8 1 0 1 0 - Disable FOTA WEB Status
1 – Enable
13000 Char fm.teltonika.lt 0 55 String FOTA WEB Domain
13001 Uint16 5000 0 65535 Number FOTA WEB Port
13002 Uint16 720 30 65535 Number FOTA WEB Period

SMS/Call settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3000 Uint8 0 0 1 0 – Disable Allow SMS data sending
1 – Enable
3001 Char "" 0 16 String Data Send Number
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3003 Char "" 0 5 String Login
3004 Char "" 0 5 String Password
3006 Uint16 UTC+00:00 UTC-12:00 UTC+13:00 Time zone SMS event Time Zone
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3005 Uint8 0 0 4 0 – Do nothing Incoming call action
1 – Hangup
2 – Report position
3 – Spy call
4 – Auto answer
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3007 Uint8 0 0 7 (3 for FMB125) 0 – Disable Outgoing call trigger
1 – DIN1
2 – Crash event
3 – DIN1 and Crash event
4 – DIN2
5 – DIN1 and DIN2
6 – DIN2 and Crash event
7 – DIN1, DIN2 and Crash event
3008 Uint8 0 0 10 GSM number GSM number index
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
4000-4199 Char "" 0 16 String Authorized number
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
6000-6009 Char "" 0 16 String Predefined number

Tracking settings

Records settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
107 Uint8 2 0 2 0 – After position fix Saving sending mode
1 – Always
2 – After time sync
1002 Uint8 0 0 1 0 – Newest Sort by
1 – Oldest
113 Uint8 1 1 1 1 – Codec 8 Extended
Data Protocol

Records profile settings

On Stop

Home

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10000 Uint16 3600 0 2592000 Min Period
10004 Uint8 1 1 255 Min Saved Records
10005 Uint16 120 0 2592000 Send Period

Roaming

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10100 Uint16 3600 0 2592000 Min Period
10104 Uint8 1 1 255 Min Saved Records
10105 Uint16 0 0 2592000 Send Period

Moving

Home

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10050 Uint16 300 0 2592000 Min Period
10051 Uint16 100 0 65535 Min Distance
10052 Uint8 10 0 180 Min Angle
10053 Uint8 10 0 100 Min Speed Delta
10054 Uint8 1 1 255 Min Saved Records
10055 Uint16 120 0 2592000 Send Period

Roaming

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10150 Uint16 300 0 2592000 Min Period
10151 Uint16 100 0 65535 Min Distance
10152 Uint8 10 0 180 Min Angle
10153 Uint8 10 0 100 Min Speed Delta
10154 Uint8 1 1 255 Min Saved Records
10155 Uint16 0 0 2592000 Send Period

Features

Driving behavior

Overspeeding

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1025500 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority
11104 Uint16 90 0 260 km/h Max speed

Trip

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1025000 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority
11803 Uint8 5 0 255 km/h Start speed
11804 Uint16 60 0 65535 Seconds Ignition OFF timeout

Odometer

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1001600 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority
11807 Uint32 0 0 4294967 Kilometer Odometer value


Vehicle protection

Unplug Detection

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1025200 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority

Other features

Static navigation

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
106 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority

Digital output overcurrent recovery

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
350 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority

|}