| style="text-align: center; vertical-align: center;" |7 – Digital Input, Accelerometer or Power Voltage | | style="text-align: center; vertical-align: center;" |7 – Digital Input, Accelerometer or Power Voltage | ||
+ | |- | ||
+ | ! style="text-align: center; vertical-align: center;" |104 | ||
+ | | style="text-align: center; vertical-align: center;" |Uint16 | ||
+ | | style="text-align: center; vertical-align: center;" |30000 | ||
+ | | style="text-align: center; vertical-align: center;" |0 | ||
+ | | style="text-align: center; vertical-align: center;" |30000 | ||
+ | | style="text-align: center; vertical-align: center;" |mV | ||
+ | | style="text-align: center; vertical-align: center;" |High voltage | ||
+ | |- | ||
+ | ! style="text-align: center; vertical-align: center;" |105 | ||
+ | | style="text-align: center; vertical-align: center;" |Uint16 | ||
+ | | style="text-align: center; vertical-align: center;" |13200 | ||
+ | | style="text-align: center; vertical-align: center;" |0 | ||
+ | | style="text-align: center; vertical-align: center;" |29999 | ||
+ | | style="text-align: center; vertical-align: center;" |mV | ||
+ | | style="text-align: center; vertical-align: center;" |Low voltage | ||
+ | |- | ||
|} | |} | ||
==Movement settings== | ==Movement settings== | ||
Line 258: | Line 275: | ||
| style="text-align: center; vertical-align: center;" |15 – Accelerometer, GNSS, Power Voltage or Digital Input | | style="text-align: center; vertical-align: center;" |15 – Accelerometer, GNSS, Power Voltage or Digital Input | ||
|} | |} | ||
+ | ==GNSS settings== | ||
+ | |||
+ | |||
=Tracking settings= | =Tracking settings= | ||
==Records settings== | ==Records settings== |
Revision as of 14:48, 29 April 2024
Mobile network
Mobile data settings
SIM 1 Settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
2001 | Char | "" | 0 | 32 | String | APN |
2002 | Char | "" | 0 | 32 | String | APN username |
2003 | Char | "" | 0 | 32 | String | APN password |
2016 | Uint8 | 1 | 0 | 1 | 0 – PAP | GPRS authentication |
1 – CHAP |
Server Settings
Primary server settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
2004 | Char | "" | 0 | 55 | String | Domain |
2005 | Uint16 | 0 | 0 | 65535 | Number | Port |
2006 | Uint8 | 0 | 0 | 3 | 0 – TCP | Protocol |
1 – UDP |
Server communication settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1000 | Uint32 | 300 | 30 | 259200 | Seconds | Open link timeout |
1001 | Uint16 | 30 | 5 | 300 | Seconds | Response timeout |
1003 | Uint16 | 0 | 0 | 300 | Seconds | Keep-alive |
FOTA WEB settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
13003 | Uint8 | 1 | 0 | 1 | 0 - Disable | FOTA WEB Settings |
1 – Enable | ||||||
13000 | Char | fm.teltonika.lt | 0 | 55 | String | Domain |
13001 | Uint16 | 5005 | 0 | 65535 | Number | Port |
13001 | Uint16 | 5055 | 0 | 65535 | Number | Pinger port |
System parameters
Ignition settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
101 | Uint8 | 4 | 2 | 7 | 1 – Digital Input | Ignition settings |
2 – Power Voltage | ||||||
3 – Digital Input or Power Voltage | ||||||
4 - Accelerometer | ||||||
5 - Digital Input or Accelerometer | ||||||
6 - Accelerometer or Power Voltage | ||||||
7 – Digital Input, Accelerometer or Power Voltage | ||||||
104 | Uint16 | 30000 | 0 | 30000 | mV | High voltage |
105 | Uint16 | 13200 | 0 | 29999 | mV | Low voltage |
Movement settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
138 | Uint8 | 2 | 1 | 15 | 1 – Accelerometer | Movement source |
2 – GNSS | ||||||
3 – Accelerometer or GNSS | ||||||
4 - Power Voltage | ||||||
5 - Accelerometer or Power Voltage | ||||||
6 - GNSS or Power Voltage | ||||||
7 – Accelerometer, GNSS or Power Voltage | ||||||
8 – Digital Input | ||||||
9 – Accelerometer or Digital Input | ||||||
10 – Digital Input or GNSS | ||||||
12 – Digital Input or Power Voltage | ||||||
15 – Accelerometer, GNSS, Power Voltage or Digital Input |
GNSS settings
Tracking settings
Records settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
107 | Uint8 | 2 | 0 | 2 | 0 – After position fix | Saving sending mode |
1 – Always | ||||||
2 – After time sync | ||||||
1002 | Uint8 | 0 | 0 | 1 | 0 – Newest | Sort by |
1 – Oldest | ||||||
113 | Uint8 | 1 | 1 | 1 | 1 – Codec 8 Extended | |
Data Protocol |
Records profile settings
On Stop
Home
Parameter ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10000 | Uint16 | 3600 | 0 | 2592000 | Min Period |
10004 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10005 | Uint16 | 120 | 0 | 2592000 | Send Period |
Roaming
Parameter ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10100 | Uint16 | 3600 | 0 | 2592000 | Min Period |
10104 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10105 | Uint16 | 0 | 0 | 2592000 | Send Period |
Moving
Home
Parameter ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10050 | Uint16 | 300 | 0 | 2592000 | Min Period |
10051 | Uint16 | 100 | 0 | 65535 | Min Distance |
10052 | Uint8 | 10 | 0 | 180 | Min Angle |
10053 | Uint8 | 10 | 0 | 100 | Min Speed Delta |
10054 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10055 | Uint16 | 120 | 0 | 2592000 | Send Period |
Roaming
Parameter ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10150 | Uint16 | 300 | 0 | 2592000 | Min Period |
10151 | Uint16 | 100 | 0 | 65535 | Min Distance |
10152 | Uint8 | 10 | 0 | 180 | Min Angle |
10153 | Uint8 | 10 | 0 | 100 | Min Speed Delta |
10154 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10155 | Uint16 | 0 | 0 | 2592000 | Send Period |
Features
Driving behavior
Overspeeding
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1025500 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority | ||||||
11104 | Uint16 | 90 | 0 | 260 | km/h | Max speed |
Trip
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1025000 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority | ||||||
11803 | Uint8 | 5 | 0 | 255 | km/h | Start speed |
11804 | Uint16 | 60 | 0 | 65535 | Seconds | Ignition OFF timeout |
Odometer
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1001600 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority | ||||||
11807 | Uint32 | 0 | 0 | 4294967 | Kilometer | Odometer value |
Vehicle protection
Unplug Detection
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1025200 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority |
Other features
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
106 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority |
Digital output overcurrent recovery
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
350 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority |
SMS / Call settings
SMS Security
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
3004 | Char | "" | 0 | 5 | String | Password |