Difference between revisions of "Template:FTXXXX Device Family Parameter list"
From Wiki Knowledge Base | Teltonika GPS
Line 377: | Line 377: | ||
|- | |- | ||
|} | |} | ||
+ | ==Time synchronization settings== | ||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! rowspan="2" style="width: 150px; background: black; color: white;" |'''Parameter ID''' | ||
+ | ! rowspan="2" style="width: 150px; background: black; color: white;" |'''Parameter Type''' | ||
+ | ! rowspan="2" style="width: 150px; background: black; color: white;" |'''Default value''' | ||
+ | ! colspan="2" style="width: 150px; background: black; color: white;" |'''Value range''' | ||
+ | ! rowspan="2" style="width: 150px; background: black; color: white;" |'''Value''' | ||
+ | ! rowspan="2" style="width: 150px; background: black; color: white;" |'''Parameter name''' | ||
+ | |- | ||
+ | ! style="width: 75px; background: black; color: white;" |Min | ||
+ | ! style="width: 75px; background: black; color: white;" |Max | ||
+ | |- | ||
+ | ! style="text-align: center; vertical-align: center;" |901 | ||
+ | | style="text-align: center; vertical-align: center;" |Uint8 | ||
+ | | style="text-align: center; vertical-align: center;" |3 | ||
+ | | style="text-align: center; vertical-align: center;" |0 | ||
+ | | style="text-align: center; vertical-align: center;" |24 | ||
+ | | style="text-align: center; vertical-align: center;" |Hours | ||
+ | | style="text-align: center; vertical-align: center;" |Time synchronization settings | ||
+ | |- | ||
+ | ! style="text-align: center; vertical-align: center;" |902 | ||
+ | | style="text-align: center; vertical-align: center;" |Char | ||
+ | | style="text-align: center; vertical-align: center;" |"pool.ntp.org" | ||
+ | | style="text-align: center; vertical-align: center;" |0 | ||
+ | | style="text-align: center; vertical-align: center;" |55 | ||
+ | | style="text-align: center; vertical-align: center;" |String | ||
+ | | style="text-align: center; vertical-align: center;" |NTP server 1 | ||
+ | |- | ||
+ | ! style="text-align: center; vertical-align: center;" |903 | ||
+ | | style="text-align: center; vertical-align: center;" |Char | ||
+ | | style="text-align: center; vertical-align: center;" |"time.nist.gov" | ||
+ | | style="text-align: center; vertical-align: center;" |0 | ||
+ | | style="text-align: center; vertical-align: center;" |55 | ||
+ | | style="text-align: center; vertical-align: center;" |String | ||
+ | | style="text-align: center; vertical-align: center;" |NTP server 2 | ||
+ | |- | ||
+ | |} | ||
+ | |||
=Tracking settings= | =Tracking settings= | ||
==Records settings== | ==Records settings== |
Revision as of 15:17, 29 April 2024
Mobile network
Mobile data settings
SIM 1 Settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
2001 | Char | "" | 0 | 32 | String | APN |
2002 | Char | "" | 0 | 32 | String | APN username |
2003 | Char | "" | 0 | 32 | String | APN password |
2016 | Uint8 | 1 | 0 | 1 | 0 – PAP | GPRS authentication |
1 – CHAP |
Server Settings
Primary server settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
2004 | Char | "" | 0 | 55 | String | Domain |
2005 | Uint16 | 0 | 0 | 65535 | Number | Port |
2006 | Uint8 | 0 | 0 | 3 | 0 – TCP | Protocol |
1 – UDP |
Server communication settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1000 | Uint32 | 300 | 30 | 259200 | Seconds | Open link timeout |
1001 | Uint16 | 30 | 5 | 300 | Seconds | Response timeout |
1003 | Uint16 | 0 | 0 | 300 | Seconds | Keep-alive |
FOTA WEB settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
13003 | Uint8 | 1 | 0 | 1 | 0 - Disable | FOTA WEB Settings |
1 – Enable | ||||||
13000 | Char | fm.teltonika.lt | 0 | 55 | String | Domain |
13001 | Uint16 | 5005 | 0 | 65535 | Number | Port |
13001 | Uint16 | 5055 | 0 | 65535 | Number | Pinger port |
System parameters
Ignition settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
101 | Uint8 | 4 | 2 | 7 | 1 – Digital Input | Ignition settings |
2 – Power Voltage | ||||||
3 – Digital Input or Power Voltage | ||||||
4 - Accelerometer | ||||||
5 - Digital Input or Accelerometer | ||||||
6 - Accelerometer or Power Voltage | ||||||
7 – Digital Input, Accelerometer or Power Voltage | ||||||
104 | Uint16 | 30000 | 0 | 30000 | mV | High voltage |
105 | Uint16 | 13200 | 0 | 29999 | mV | Low voltage |
Movement settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
138 | Uint8 | 2 | 1 | 15 | 1 – Accelerometer | Movement source |
2 – GNSS | ||||||
3 – Accelerometer or GNSS | ||||||
4 - Power Voltage | ||||||
5 - Accelerometer or Power Voltage | ||||||
6 - GNSS or Power Voltage | ||||||
7 – Accelerometer, GNSS or Power Voltage | ||||||
8 – Digital Input | ||||||
9 – Accelerometer or Digital Input | ||||||
10 – Digital Input or GNSS | ||||||
12 – Digital Input or Power Voltage | ||||||
15 – Accelerometer, GNSS, Power Voltage or Digital Input | ||||||
139 | Uint16 | 30000 | 0 | 30000 | mV | High voltage |
140 | Uint16 | 13200 | 0 | 29999 | mV | Low voltage |
GNSS settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
121 | Uint8 | 10 | 1 | 15 | 0 – Undefined | GNSS source |
1 – BeiDou only | ||||||
2 – GLONASS only | ||||||
3 – GLONASS and BeiDou not allowed | ||||||
4 – Galileo only | ||||||
5 – Galileo and BeiDou | ||||||
6 – Galileo and GLONASS | ||||||
7 – Galileo, GLONASS and BeiDou not allowed | ||||||
8 – GPS only | ||||||
9 – GPS and BeiDou | ||||||
10 – GPS and GLONASS | ||||||
11 – GPS, GLONASS and BeiDou not allowed | ||||||
12 – GPS and Galileo | ||||||
13 – GPS, Galileo and BeiDou | ||||||
14 – GPS, Galileo and GLONASS | ||||||
15 – GPS, Galileo, GLONASS and BeiDou |
Movement Delay
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
11206 | Uint16 | 2 | 1 | 60 | Seconds | Movement Start Delay |
11205 | Uint16 | 60 | 5 | 300 | Seconds | Movement Stop Delay |
Time synchronization settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
901 | Uint8 | 3 | 0 | 24 | Hours | Time synchronization settings |
902 | Char | "pool.ntp.org" | 0 | 55 | String | NTP server 1 |
903 | Char | "time.nist.gov" | 0 | 55 | String | NTP server 2 |
Tracking settings
Records settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
107 | Uint8 | 2 | 0 | 2 | 0 – After position fix | Saving sending mode |
1 – Always | ||||||
2 – After time sync | ||||||
1002 | Uint8 | 0 | 0 | 1 | 0 – Newest | Sort by |
1 – Oldest | ||||||
113 | Uint8 | 1 | 1 | 1 | 1 – Codec 8 Extended | |
Data Protocol |
Records profile settings
On Stop
Home
Parameter ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10000 | Uint16 | 3600 | 0 | 2592000 | Min Period |
10004 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10005 | Uint16 | 120 | 0 | 2592000 | Send Period |
Roaming
Parameter ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10100 | Uint16 | 3600 | 0 | 2592000 | Min Period |
10104 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10105 | Uint16 | 0 | 0 | 2592000 | Send Period |
Moving
Home
Parameter ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10050 | Uint16 | 300 | 0 | 2592000 | Min Period |
10051 | Uint16 | 100 | 0 | 65535 | Min Distance |
10052 | Uint8 | 10 | 0 | 180 | Min Angle |
10053 | Uint8 | 10 | 0 | 100 | Min Speed Delta |
10054 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10055 | Uint16 | 120 | 0 | 2592000 | Send Period |
Roaming
Parameter ID | Parameter Type | Default value | Value range | Parameter name | |
---|---|---|---|---|---|
Min | Max | ||||
10150 | Uint16 | 300 | 0 | 2592000 | Min Period |
10151 | Uint16 | 100 | 0 | 65535 | Min Distance |
10152 | Uint8 | 10 | 0 | 180 | Min Angle |
10153 | Uint8 | 10 | 0 | 100 | Min Speed Delta |
10154 | Uint8 | 1 | 1 | 255 | Min Saved Records |
10155 | Uint16 | 0 | 0 | 2592000 | Send Period |
Features
Driving behavior
Overspeeding
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1025500 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority | ||||||
11104 | Uint16 | 90 | 0 | 260 | km/h | Max speed |
Trip
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1025000 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority | ||||||
11803 | Uint8 | 5 | 0 | 255 | km/h | Start speed |
11804 | Uint16 | 60 | 0 | 65535 | Seconds | Ignition OFF timeout |
Odometer
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1001600 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority | ||||||
11807 | Uint32 | 0 | 0 | 4294967 | Kilometer | Odometer value |
Vehicle protection
Unplug Detection
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1025200 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority |
Other features
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
106 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority |
Digital output overcurrent recovery
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
350 | Uint8 | 0 | 0 | 2 | 0 – Disable | Priority |
1 – Low priority | ||||||
2 – High priority |
SMS / Call settings
SMS Security
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
3004 | Char | "" | 0 | 5 | String | Password |