Difference between revisions of "FMB965 firmware errata"
From Wiki Knowledge Base | Teltonika GPS
Line 66: | Line 66: | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: center; vertical-align: center; background: white;" |{{{release_date| 2024.06.07}}} | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: center; vertical-align: center; background: white;" |{{{release_date| 2024.06.07}}} | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: top; background: white;" | | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: top; background: white;" | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
* '''NEW!''' '''[[EYE_SENSOR_/_BTSMP1#Teltonika_configurator_new_functionalities_.28Evaluation_firmware_.2F_EYE_Sensor_filtering_by_name.29|TELTONIKA EYE Beacon and EYE Sensor easy configuration]]''' functionalities added | * '''NEW!''' '''[[EYE_SENSOR_/_BTSMP1#Teltonika_configurator_new_functionalities_.28Evaluation_firmware_.2F_EYE_Sensor_filtering_by_name.29|TELTONIKA EYE Beacon and EYE Sensor easy configuration]]''' functionalities added | ||
* '''NEW!''' '''[[EYE_SENSOR_/_BTSMP1#Teltonika_configurator_new_functionalities_.28Evaluation_firmware_.2F_EYE_Sensor_filtering_by_name.29|TELTONIKA EYE Beacon Lost & Found and Proximity Event]]''' functionalities added | * '''NEW!''' '''[[EYE_SENSOR_/_BTSMP1#Teltonika_configurator_new_functionalities_.28Evaluation_firmware_.2F_EYE_Sensor_filtering_by_name.29|TELTONIKA EYE Beacon Lost & Found and Proximity Event]]''' functionalities added | ||
Line 88: | Line 83: | ||
* '''CHANGED!''' SMS/GPRS command '''[[FMB_cpureset|"cpureset"]]''' protection functionality | * '''CHANGED!''' SMS/GPRS command '''[[FMB_cpureset|"cpureset"]]''' protection functionality | ||
* '''CHANGED!''' '''[[Advanced_Pulse_Counter|Pulse Counter]]''' reworked | * '''CHANGED!''' '''[[Advanced_Pulse_Counter|Pulse Counter]]''' reworked | ||
+ | * Improved reconnection to new operator time if GPRS was unavailable with initial operator | ||
+ | * Fixed pro-longed reconnection to new operator due to record tasks interrupting operator search | ||
+ | * Fixed network session closing when current operator is added to blacklist | ||
+ | * Fixed Digital Output state restore after firmware update | ||
+ | * GNSS status element state improvements | ||
* Record saving and sending improvements | * Record saving and sending improvements | ||
* DOUT state saving improvements | * DOUT state saving improvements |
Revision as of 08:13, 14 June 2024
Main Page > Basic Trackers > FMB965 > FMB965 firmware errataIntroduction
We are always improving our devices performance, stability and reliability. That’s why Teltonika is one of the leading GNSS trackers manufacturers in the world.
This document describes FMB965 devices firmware improvements, changes, new features implementations as well as current firmware release version.
FIRMWARE VERSION | SUPPORTED HARDWARE |
---|---|
03.27.10.Rev.4XX | FMB965 |
03.29.00.Rev.93X | FMB965 |
Evaluation firmware branches
Newly introduced Teltonika Telematics products start their lifecycle and mass production running evaluation branch firmware versions, which may be based on older BASE firmware version or seperate firmware branch, therefore may have different features. Such products do not immediately receive identical improvements as products in BASE firmware until their support is added. Currently such products are:
FIRMWARE VERSION | HARDWARE |
---|---|
03.29.00.Rev.457 | FMC880, FMM880, FMC800, FMM800, FMM80A |
03.28.07.Rev.159 | FMB150, FMC150, FMM150 |
03.27.10.Rev.482 | FMB930 |
03.29.00.Rev.931 | FMB965 |
03.28.04.Rev.273 | FMP100 |
Firmware versioning
- Structure
FMB(T).VER.[XX
].[YY
].[ZZ
].Rev.[##
] _[ID###
]
- Syntax description
XX
– major FW version.YY
– branch number, shows major changes in firmware, i.e. new module support added or new major feature added.ZZ
– major changes like bigger fixes, improvements and new features addition.##
– minor changes like small fixes and improvements.ID[###]
– Spec ID KEY – Specific clients FW changes.
Firmware versions
FIRMWARE VERSION | RELEASE DATE | CHANGES |
---|---|---|
03.29.00.Rev.931 (recommended for FMB965) |
2024.06.07 |
|
03.27.10.Rev.487 (recommended for FMB965) |
2023.12.22 |
|
03.27.10.Rev.464 (recommended for FMB965) |
2022.08.05 |
|
03.27.10.Rev.460 (recommended for FMB965) |
2022.05.05 |
|