Jump to content

TEST-X: Difference between revisions

From Teltonika Telematics Wiki
No edit summary
No edit summary
Line 8: Line 8:
<tr>
<tr>


<td style="vertical-align: middle; text-align: center;"> Immobilizer </td>
<td style="vertical-align: middle; text-align: center;"> Auto geofence </td>
<td style="vertical-align: middle; text-align: center;"> 11700 </td>
<td style="vertical-align: middle; text-align: center;"> 1017500 </td>
<td style="vertical-align: middle; text-align: center;"> Disables, or enables and sets priority of the event record generated upon successful or failed authorization attempts.Authorization source </td>
<td style="vertical-align: middle; text-align: center;"> Disables, or enables and sets priority for record generation. </td>
<td style="vertical-align: middle; text-align: left;"> '''0 =''' Disable scenario. <br>
<td style="vertical-align: middle; text-align: left;"> ''0''' = Disable Disable scenario.
'''1 =''' Low priority Device makes an additional record with indication of event cause. </td>
'''1''' = Low priority Device makes an additional record with indication of event cause.
'''2''' = High priority Device makes an additional record with high priority flag and immediately sends an event packet to the server by GPRS. </td>
 
</tr>  
</tr>  
<tr>
<tr>


<td style="vertical-align: middle; text-align: center;"> Authorization source </td>
<td style="vertical-align: middle; text-align: center;"> Generate event </td>
<td style="vertical-align: middle; text-align: center;"> 11703 </td>
<td style="vertical-align: middle; text-align: center;"> 20001 </td>
<td style="vertical-align: middle; text-align: center;"> Selects the type of authorization element to be used. </td>
<td style="vertical-align: middle; text-align: center;"> Defines when the event will be generated </td>
<td style="vertical-align: middle; text-align: left;"> '''0 =''' No authorization selected. <br>  
<td style="vertical-align: middle; text-align: left;"> '''0 =''' On exit <br>
'''1 =''' 1-Wire authorization selected.
'''1 =''' On enter <br>
'''2 =''' On both <br>
  </td>
  </td>


Line 26: Line 29:
<tr>
<tr>


<td style="vertical-align: middle; text-align: center;"> Ignition OFF timeout (s) </td>
<td style="vertical-align: middle; text-align: center;"> Activation timeout (s) </td>
<td style="vertical-align: middle; text-align: center;"> 60068 </td>
<td style="vertical-align: middle; text-align: center;"> 20002 </td>
<td style="vertical-align: middle; text-align: center;"> Sets the time in seconds after the ignition is turned off before the driver's authorization is automatically revoked. </td>
<td style="vertical-align: middle; text-align: center;"> Sets the duration in seconds for two conditions: <br>
<td style="vertical-align: middle; text-align: left;"> Minimum value '''= 1''' <br>
1. '''In Wait State:''' how long the vehicle must be stationary with a GNSS fix before the geofence is armed. <br>
2. '''In Active State:''' how long the vehicle must be moving without a GNSS fix to trigger an alarm.
</td>
<td style="vertical-align: middle; text-align: left;"> Minimum value '''= 0''' <br>
Maximum value '''= 65535''' </td>
Maximum value '''= 65535''' </td>


Line 35: Line 41:
<tr>
<tr>


<td style="vertical-align: middle; text-align: center;"> Eventual records </td>
<td style="vertical-align: middle; text-align: center;"> Radius (m) </td>
<td style="vertical-align: middle; text-align: center;"> 11701</td>
<td style="vertical-align: middle; text-align: center;"> 20003 </td>
<td style="vertical-align: middle; text-align: center;"> Enables feature status sending only when the event happens (an eventual record). When disabled, feature status will be sent with both eventual and periodical records. </td>
<td style="vertical-align: middle; text-align: center;"> Sets the radius of the circular geofence in meters, measured from the vehicle's position when armed. </td>
<td style="vertical-align: middle; text-align: left;"> '''0''' = Disable <br>
<td style="vertical-align: middle; text-align: left;"> inimum value '''= 0''' <br>
'''1''' = Enable </td>
Maximum value '''= 1000000''' </td>


</tr>  
</tr>  
<tr>
<tr>


<td style="vertical-align: middle; text-align: center;"> Bypass authorization </td>
<td style="vertical-align: middle; text-align: center;"> Deactivate by </td>
<td style="vertical-align: middle; text-align: center;"> 11029</td>
<td style="vertical-align: middle; text-align: center;"> 20004 </td>
<td style="vertical-align: middle; text-align: center;"> Allows to bypass authorization when ignition is turned on and a duration expires. </td>
<td style="vertical-align: middle; text-align: center;"> Selects the source that will deactivate an armed geofence and return the system to the Wait State. </td>
<td style="vertical-align: middle; text-align: left;"> '''0 =''' Disabled
<td style="vertical-align: middle; text-align: left;"> 0 - Power Voltage: Deactivates if external voltage exceeds a predefined threshold.
'''0-65535 =''' Enabled  </td>
'''1 = Digital Input 1:''' Deactivates if DIN1 becomes active. <br>
 
'''2 = Digital Input 2:''' Deactivates if DIN2 becomes active. <br>
</tr>
'''3 = Digital Input 3:''' Deactivates if DIN3 becomes active. <br>
<tr>
'''4 = iButton:''' Deactivates if an authorized iButton is presented.  
 
</td>
<td style="vertical-align: middle; text-align: center;"> Bypass authorization timeout (s) </td>
<td style="vertical-align: middle; text-align: center;"> 11029</td>
<td style="vertical-align: middle; text-align: center;"> Sets duration which starts when ignition is turned on. When duration expires immobilizer is turned off, even if the user was not authenticated. </td>
<td style="vertical-align: middle; text-align: left;"> Minimum value '''= 1''' <br>
Maximum value '''= 65535''' </td>
 
</tr>
<tr>
 
<td style="vertical-align: middle; text-align: center;"> Output control </td>
<td style="vertical-align: middle; text-align: center;"> 65535</td>
<td style="vertical-align: middle; text-align: center;"> Selects which Digital Output is used to control the immobilizer relay. </td>
<td style="vertical-align: middle; text-align: left;"> '''0 =''' None DOUTs are disabled in this scenario. <br>
'''1 =''' DOUT1 DOUT1 is enabled in this scenario. <br>
'''2 =''' DOUT2 DOUT2 is enabled in this scenario. <br>
'''3 =''' DOUT3 DOUT3 is enabled in this scenario. </td>


</tr>  
</tr>  
</table>
</table>

Revision as of 15:33, 11 September 2025

PARAMETER NAME PARAMETER ID (RELATED AVL ID) DESCRIPTION VALUES
Auto geofence 1017500 Disables, or enables and sets priority for record generation. 0' = Disable Disable scenario.

1 = Low priority Device makes an additional record with indication of event cause.

2 = High priority Device makes an additional record with high priority flag and immediately sends an event packet to the server by GPRS.
Generate event 20001 Defines when the event will be generated 0 = On exit

1 = On enter
2 = On both

Activation timeout (s) 20002 Sets the duration in seconds for two conditions:

1. In Wait State: how long the vehicle must be stationary with a GNSS fix before the geofence is armed.
2. In Active State: how long the vehicle must be moving without a GNSS fix to trigger an alarm.

Minimum value = 0
Maximum value = 65535
Radius (m) 20003 Sets the radius of the circular geofence in meters, measured from the vehicle's position when armed. inimum value = 0
Maximum value = 1000000
Deactivate by 20004 Selects the source that will deactivate an armed geofence and return the system to the Wait State. 0 - Power Voltage: Deactivates if external voltage exceeds a predefined threshold.

1 = Digital Input 1: Deactivates if DIN1 becomes active.
2 = Digital Input 2: Deactivates if DIN2 becomes active.
3 = Digital Input 3: Deactivates if DIN3 becomes active.
4 = iButton: Deactivates if an authorized iButton is presented.