System settings have 5 configurable parameters:
- Sleep mode - where user can turn GPS sleep/deep sleep on or off;
- Sleep timeout - timer which starts after every sleep condition is met and will end up with device going to sleep mode;
- Ignition Source sets ignition triggered functionalities to be triggered by:
- Power Voltage (if voltage is between High Voltage Level and Low Voltage Level the ignition is considered to be turned on);
- Digital Input 1;
- Digital Input 2;
- Digital Input 3;
- Digital Input 4;
- Movement (if accelerometer/movement sensor detects movement then ignition is on, if movement stops – ignition is off).
Also if Power Voltage is chosen for ignition source there is possibility to choose Manual ignition detection or automatic ignition detection. For manual ignition user has to choose power voltage levels by himself. For
automatic ignition FMB630 automatically detects ignition, ignition is on if power voltage is between 13,2 – 16 V, or 27 – 32 V.