Template:FM36YX I/O settings: Difference between revisions
Appearance
No edit summary |
No edit summary |
||
| Line 92: | Line 92: | ||
| style="text-align: left; vertical-align: center;" | Area Code | | style="text-align: left; vertical-align: center;" | Area Code | ||
| style="text-align: left; vertical-align: top;" | Location Area code (LAC), it depends on GSM operator.<br />It provides unique number which assigned to a set of base GSM stations.<br />Max value: 65536 | | style="text-align: left; vertical-align: top;" | Location Area code (LAC), it depends on GSM operator.<br />It provides unique number which assigned to a set of base GSM stations.<br />Max value: 65536 | ||
|- | |||
! style="text-align: left; vertical-align: top;" | 21 | |||
| style="text-align: left; vertical-align: top;" | Dallas Temperature 1 | |||
| style="text-align: left; vertical-align: top;" | 10 * Degrees (°C), -55 - +115, if 3000 – Dallas error | |||
|- | |||
! style="text-align: left; vertical-align: top;" | 22 | |||
| style="text-align: left; vertical-align: top;" | Dallas Temperature 2 | |||
| style="text-align: left; vertical-align: top;" | 10 * Degrees (°C), -55 - +115, if 3000 – Dallas error | |||
|- | |||
! style="text-align: left; vertical-align: top;" | 23 | |||
| style="text-align: left; vertical-align: top;" | Dallas Temperature 3 | |||
| style="text-align: left; vertical-align: top;" | 10 * Degrees (°C), -55 - +115, if 3000 – Dallas error | |||
|- | |||
! style="text-align: left; vertical-align: top;" | 24 | |||
| style="text-align: left; vertical-align: top;" | Battery Voltage | |||
| style="text-align: left; vertical-align: top;" | Voltage: mV | |||
|- | |||
! style="text-align: left; vertical-align: top;" | 25 | |||
| style="text-align: left; vertical-align: top;" | Battery Charging Current | |||
| style="text-align: left; vertical-align: top;" | Current: mA | |||
|- | |||
! style="text-align: left; vertical-align: top;" | 26 | |||
| style="text-align: left; vertical-align: top;" | Ignition | |||
| style="text-align: left; vertical-align: top;" | Ignition status indication. Logic: 0 / 1 | |||
|- | |||
! style="text-align: left; vertical-align: top;" | 27 | |||
| style="text-align: left; vertical-align: top;" | Network Type | |||
| style="text-align: left; vertical-align: top;" | 0 – 3G network, 1 – 2G network | |||
|- | |||
! style="text-align: left; vertical-align: top;" | 28 | |||
| style="text-align: left; vertical-align: top;" | Continuous Odometer | |||
| style="text-align: left; vertical-align: top;" | Distance which device has been traveled with ignition ON: m | |||
|- | |||
! style="text-align: left; vertical-align: top;" | 29 | |||
| style="text-align: left; vertical-align: top;" | Dallas temperature ID1 | |||
| style="text-align: left; vertical-align: top;" | 1st connected dallas temperature sensor ID | |||
|- | |||
! style="text-align: left; vertical-align: top;" | 30 | |||
| style="text-align: left; vertical-align: top;" | Dallas temperature ID2 | |||
| style="text-align: left; vertical-align: top;" | 2nd connected dallas temperature sensor ID | |||
|- | |||
! style="text-align: left; vertical-align: top;" | 31 | |||
| style="text-align: left; vertical-align: top;" | Dallas temperature ID3 | |||
| style="text-align: left; vertical-align: top;" | 3rd connected dallas temperature sensor ID | |||
|- | |||
! style="width: 200px; background: black; color: white;" colspan="3" | Eventual I/O elements (generate and send record to server only if appropriate conditions are met) | |||
|- | |- | ||
|} | |} | ||
Revision as of 08:18, 1 June 2018
When no I/O element is enabled, AVL packet comes with GNSS information only. After enabling I/O element(s) AVL packet along with GNSS information contains current value(s) of enabled I/O element.
| Permanent I/O elements (are always sent to server if enabled) | ||
|---|---|---|
| No. | Property Name | Description |
| 00 | Digital Input Status 1 | Logic: 0 / 1 |
| 01 | Digital Input Status 2 | Logic: 0 / 1 |
| 02 | Digital Input Status 3 | Logic: 0 / 1 |
| 03 | Digital Input Status 4 | Logic: 0 / 1 |
| 04 | Analog Input 1 | Voltage: mV, 0 – 30 V |
| 05 | Digital Output 1 | Logic: 0 / 1 |
| 06 | Digital Output 2 | Logic: 0 / 1 |
| 07 | GNSS PDOP | Probability * 10; 0-500 |
| 08 | GNSS HDOP | Probability * 10; 0-500 |
| 09 | External Voltage | Voltage: mV, 0 – 30 V |
| 10 | GNSS Power | States: 0 – off state (when GPS module is off) 1 – Reserved 2 – GPS ready (antenna is working, but with no GPS fix) 3 – GPS working (antenna is working and has GPS fix) 4 – GPS sleep (when device is in GPS sleep mode) 5 – Overcurrent (The only condition to get value 5, then antenna is damaged and short circuit) |
| 11 | Movement Sensor | 0 – not moving, 1 – moving. |
| 12 | Odometer Value | Distance between two records: m |
| 13 | GSM Operator | Currently used GSM Operator code |
| 14 | Speed (Km/h) | Value in km/h, 0 – xxx km/h |
| 15 | iButton ID | iButton ID number |
| 16 | Mode | 0 – home on stop, 1 – home on move, 2 – roaming on stop, 3 – roaming on move, 4 – unknown on stop, 5 – unknown on move |
| 17 | GSM Signal | GSM signal level value in scale 1 – 5 |
| 18 | Deep Sleep | 0 – not deep sleep mode, 1 – deep sleep mode |
| 19 | Cell ID | GSM base station ID |
| 20 | Area Code | Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations. Max value: 65536 |
| 21 | Dallas Temperature 1 | 10 * Degrees (°C), -55 - +115, if 3000 – Dallas error |
| 22 | Dallas Temperature 2 | 10 * Degrees (°C), -55 - +115, if 3000 – Dallas error |
| 23 | Dallas Temperature 3 | 10 * Degrees (°C), -55 - +115, if 3000 – Dallas error |
| 24 | Battery Voltage | Voltage: mV |
| 25 | Battery Charging Current | Current: mA |
| 26 | Ignition | Ignition status indication. Logic: 0 / 1 |
| 27 | Network Type | 0 – 3G network, 1 – 2G network |
| 28 | Continuous Odometer | Distance which device has been traveled with ignition ON: m |
| 29 | Dallas temperature ID1 | 1st connected dallas temperature sensor ID |
| 30 | Dallas temperature ID2 | 2nd connected dallas temperature sensor ID |
| 31 | Dallas temperature ID3 | 3rd connected dallas temperature sensor ID |
| Eventual I/O elements (generate and send record to server only if appropriate conditions are met) | ||
Monitoring
I/O monitoring starts after enabling I/O element and setting up I/O parameters as it is shown below:

Event generating
Events happen when the value of enabled I/O intersects thresholds (enter, exit or on both) predefined by High and Low level thresholds. Table below defines all available values of I/O settings.
| Setting | Value |
|---|---|
| Priority | low, high |
| High level | maximum threshold |
| Low level | minimum threshold |
| Generate event | on interval enter, on interval exit, on both enter and exit |
| Average constant | 1 – 232 (4 Bytes) |

Hysteresis