Difference between revisions of "FM36YX Device Family Parameter list"
From Wiki Knowledge Base | Teltonika GPS
(Created page with "==Parameters value types== ==System parameters== ==Records parameters== ==GSM parameters== ==Data aquisition parameters== ==Features parameters== ==I/O parameters== ==L...") |
Simkunas.ma (talk | contribs) |
||
Line 2: | Line 2: | ||
==System parameters== | ==System parameters== | ||
− | + | {{Template:FM36_System_Parameters}} | |
==Records parameters== | ==Records parameters== | ||
Revision as of 13:12, 1 June 2018
Main Page > EOL Products > FM3612 > FM3612 Manual > FM36YX Device Family Parameter listParameters value types
System parameters
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1000 | U8 | 0 | 0 | 2 | 0 – Disabled | Sleep Settings |
1 – GPS Sleep | ||||||
2 – Deep Sleep | ||||||
200 | U8 | 1 | 1 | 3000 | - | Sleep Timeout |
1001 | U8 | 0 | 0 | 1 | 0 - 10V | Analog Input value range |
1 – 30V | ||||||
1002 | U8 | 1 | 0 | 3 | 0 - ignition | Stop Detection Source |
1 - Msensor | ||||||
2 - GPS | ||||||
3 - ignition + Msensor | ||||||
1003 | U8 | 0 | 0 | 1 | 0 - Disabled | Static Navigation |
1 – Enabled | ||||||
1004 | 0 | 0 | 2 | 0 – Power voltage | Ignition Source | |
1 – Digital input 1 | ||||||
2 – Msensor | ||||||
1005 | 30000 mV | 13000 mV | 30000 mV | High Voltage Level | ||
1006 | 13000 mV | 0 | 30000 mV | Low Voltage Level | ||
1008 | 0 | 0 | 1 | 0 - Manual | Ignition Detection | |
1 – Automatic | ||||||
1009 | U8 | 10 | 0 | 65535 | Ignition Detection Timeout | |
1007 | U8 | 60 | 0 | 65535 | GNSS FIX Timeout for Time Synchronization via NTP | |
201 | U8 | 0 | 0 | 1 | 0 - Disabled | Saving/Sending without time synchronization |
1 – Enabled | ||||||
202 | U8 | 0 | 0 | 2 | 0 – GNSS (all available) | Satellite System |
1 – GPS | ||||||
2 – GLONASS |