Difference between revisions of "Template:FMB630 Device Family Parameter list"

From Wiki Knowledge Base | Teltonika GPS
Line 783: Line 783:
 
| style="text-align: center; vertical-align: center;" |-
 
| style="text-align: center; vertical-align: center;" |-
 
|-
 
|-
! style="text-align: center; vertical-align: center;" colspan=2|Configuring Format
+
! style="text-align: center; vertical-align: center;" |Configuring Format
 
| style="text-align: center; vertical-align: center;" colspan=6|<priority>,<activationTmo>,<TowingEvtTmo>,<Duration>,<Acceleration>,<TowingAngle>,<TowingCallNr>
 
| style="text-align: center; vertical-align: center;" colspan=6|<priority>,<activationTmo>,<TowingEvtTmo>,<Duration>,<Acceleration>,<TowingAngle>,<TowingCallNr>
 
|-
 
|-
Line 829: Line 829:
 
|-
 
|-
 
! style="text-align: center; vertical-align: center;" colspan=2|Eco driving type
 
! style="text-align: center; vertical-align: center;" colspan=2|Eco driving type
| style="text-align: center; vertical-align: center;" rowspan=14|x910
+
| style="text-align: center; vertical-align: center;" rowspan=15|x910
 
| style="text-align: center; vertical-align: center;" rowspan=7|0
 
| style="text-align: center; vertical-align: center;" rowspan=7|0
 
| style="text-align: center; vertical-align: center;" rowspan=7|5
 
| style="text-align: center; vertical-align: center;" rowspan=7|5

Revision as of 08:54, 26 June 2018


!Not finished

System parameters

Parameter ID Parameter value Value type
MIN MAX Default Recommended
Sleep Mode x000 0 3 0 - U8
0 Disable
1 Enable
2 Deep sleep
3 Online deep sleep
Sleep Timeout x001 0 9000 1 - U16
Ignition source x900 0 5 0 - U8
0 Power voltage
1 DIN 1
2 DIN 2
3 DIN 3
4 DIN 4
5 Movement
High Voltage Level(for Ignition) x901 0 30000 0 - U16
Low Voltage Level (for Ignition) x902 0 30000 0 - U16


GPRS data sending settings

Parameter ID Parameter value Value type
MIN MAX Default Recommended
Server 1
GPRS Context Activation x240 0 (Disable) 1 (Enable) 0 - S8
Protocol 0 (TCP) 1 (UDP) 0 - U8
Server Response Timeout 5 300 5 - U16
Domain Empty 56 char Empty - -
Target Server Port 0 65535 0 - U16
Configuring format: <Enable>,<IP>,<port>,<protocol>,<Server Reponse Tmo>
Server 2
GPRS Context Activation x242 0 (Disable) 1 (Enable) 0 - S8
Protocol 0 (TCP) 1 (UDP) 0 - U8
Domain Empty 56 char Empty - -
Target Server Port 0 65535 0 - U16
Configuring format: <Enable>,<IP>,<port>,<protocol>


GPRS data limit settings

Parameter ID Parameter value Value type
MIN MAX Default Recommended
Enable GPRS limits x241 0 (Disable) 1 (Enable) 0 - U8
Data limit Home 1 10000 100 - U16
Data limit Roaming 1 10000 10 - U16
Configuring format: <Enable>,,

SMS security settings

Parameter ID Parameter value Value type
MIN MAX Default Recommended
SMS Login x252 Empty 5 char Empty - S8[5]
SMS Password x253 Empty 5 char Empty - S8[5]
Authorized phone numbers x260-x269 Empty 16 char Empty - S8[17]

SMS data sending settings

Parameter ID Parameter value Value type
MIN MAX Default Recommended
SMS Data x250 0 (Disable) 1 (Enable) 0 - U8
SMS Data send week time schedule x273 Binary decoding Binary decoding - - 20 byte array
Configuring format: <x1><x2><x3><x4>......<x19>

Operator list settings

Parameter ID Parameter value Value type
MIN MAX Default Recommended
Preferred Operator x271 0 99999999 0 - U32
Black List Operator x272 0 99999999 0 - U32
Configuring format:
(setparam Y271 X)
X is start position. If no X is set starts from 0
Max 19 operator codes can be set (separated by comma) in one SMS command.
Reading format:
(getparam Y271 X)
X values can be 1,2,3.
If X = 1, Operator codes from 0-19 are read from configuration and sent via SMS.
If X = 2, Operator codes from 20-39 are read from configuration and sent via SMS.
If X = 3, Operator codes from 40-49 are read from configuration and sent via SMS.
If X = any other, Operator codes from 0-19 are read from configuration and sent via SMS
*User must use X, without X value device responds that parameter is wrong or it can respond with wrong operator codes.

Data Acquisition settings

Parameter ID Parameter value Value type
MIN MAX Default Recommended
Data acquisition modes x010
Min Period (in seconds) 0 9999999 600 - U32
Min Distance (in meters) 0 65535 0 - U32
Min Angle (in degrees) 0 180 0 - U16
Min Speed (in km/h) 0 400 0 - U16
Min Speed Source 0/1/2/3/4 (0-GPS, 1-LVCAN, 2-ALLCAN, 3-FMS, 4-KLINE) 0 - U8
Min Saved Records 1 25 10 - U8
Min Send Period (in seconds) 0 9999999 600 - U32
Configuring format: <minperiod>,<mindistance>,<minangle>,<minspeed>,<minspeedsource>,<minsavedrec>,<sendperiod>

Geofencing settings

Parameter ID Parameter value Value type
MIN MAX Default Recommended
Frame Border (in meters) x020 0 9999999 1 1000 U32
Geofence Overspeed control x021 0 5 0 - U8
Geofence Zone #1 x030
Zone #1 Shape 0 (Circle) 1 (Rectangle) 0 - U32
Zone #1 priority 0 7 (exl. 3) 0 - U8
0 Low
1 High
2 Panic
4 SW21
5 SW22
6 SW23
7 SW24
Zone #1 Generate Event 0 3 0 - U8
0 No Event
1 On enter
2 On exit
3 On both
Min Angle (in degrees) 0 180 0 - U16
Zone #1 Longitude X1 (Rectangle) / X (Circle) -180 180 0 - Float
-180 180 0 - Float
Zone #1 Latitude Y1 (Rectangle) / Y (Circle) -90 90 0 - Float
-90 90 0 - Float
Zone #1 Longitude X2 (Rectangle) / R (Circle) -180 180 0 - Float
0 180 / 9999999.99 0 0 Float
Zone #1 Latitude Y2 (Rectangle) / None (Circle) -90 90 0 - Float
- - - - -
Configuring format: <shape>,<priority>,<generateEvent>,<fx1>,<fy1>,<fx2>,<fy2>
Geofence Zone #2 x031 Same configuration as Geofence Zone #1
Geofence Zone #3 x032
Geofence Zone #4 x033
Geofence Zone #5 x034
Geofence Zone #6 x035
Geofence Zone #7 x036
Geofence Zone #8 x037
Geofence Zone #9 x038
Geofence Zone #10 x039
Geofence Zone #11 x040
Geofence Zone #12 x041
Geofence Zone #13 x042
Geofence Zone #14 x043
Geofence Zone #15 x044
Geofence Zone #16 x045
Geofence Zone #17 x046
Geofence Zone #18 x047
Geofence Zone #19 x048
Geofence Zone #20 x049

Auto Geofencing settings

Parameter ID Parameter value Value type
MIN MAX Default Recommended
Autogeofence x290
Deactivate By 0 (Ignition) 1 (iButton) 0 - U8
Activation Timeout (in seconds) 0 65535 60 60 U16
Min Angle (in degrees) 0 180 0 - U16
Zone #1 priority 0 7 1 1 U8
0 Low
1 High
2 Panic
4 SW21
5 SW22
6 SW23
7 SW24
Zone #1 Generate Event 0 3 0 2 U8
0 No Event
1 On enter
2 On exit
3 On both
Radius (in meters) 0 9999999 100 100 U32
Configuring format: <deactivateBy>,<tmo>,<priority>,<eventGenerating>,<radius>


Towing Detection settings

Parameter ID Parameter value Value type
MIN MAX Default Recommended
Towing Detection X917 0 (Disable) 2 (High priority) 0 - U8
Activation Tmo (min) 0 1440 5 - -
Ignition Check (sec) 0 60 5 - -
Duration (ms) 100 5000 1000 1000 -
Acceleration 0.15 5 0.25 0.25 m/s^2 -
Angle (deg.) 0.5 5 1.0 1.0 U8
Make Call Number 0 9 - - -
Configuring Format <priority>,<activationTmo>,<TowingEvtTmo>,<Duration>,<Acceleration>,<TowingAngle>,<TowingCallNr>

iButton List

Parameter ID Parameter value Value type
MIN MAX Default Recommended
Authorized iButtons 500-999 0 FFFFFFFF 0 - U64
FFFFFFFF

Eco/Green driving settings

Parameter ID Parameter value Value type
MIN MAX Default Recommended
Eco driving type x910 0 5 0 - U8
0 Disable
1 No DOUT control
2 DOUT1 control
3 DOUT2 control
4 DOUT3 control
5 DOUT4 control
FFFFFFFF
Eco source 0 (accelerometer) 1 (GPS) 0 - U8
Max Acceleration Force 5 100 22 25 Float
Max Braking Force 5 100 25 35 Float
Max Cornering Force 5 100 21 - Float
Acceleration Active Output Duration 0 100 1 - Float
Breaking Active Output Duration 0 100 1 - Float
Cornering Active Output Duration 0 100 1 - Float
Configuring format: <Eco driving type>,<Ecosource><MaxAcceleration>,<MaxBraking>,<MaxCornering>,<AccOutputDuration>,<BrakingOutputDuration>,<CorneringOutputDuration>

Overspeeding settings

Immobilizer settings

Excessive Idling settings

Jamming settings

iButton Notification settings

Crash Detection settings

Trip settings

Global and External devices parameters

CAN