Template:FMA Device Family Features Parameter list: Difference between revisions
Appearance
No edit summary |
|||
| Line 226: | Line 226: | ||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Parameter ID''' | ! style="width: 150px; background: black; color: white;" rowspan=2 |'''Parameter ID''' | ||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Parameter Type''' | ! style="width: 150px; background: black; color: white;" rowspan=2 |'''Parameter Type''' | ||
! style="width: 150px; background: black; color: white;" rowspan=2 |''' | ! style="width: 150px; background: black; color: white;" rowspan=2 |'''Recommended value''' | ||
! style="width: 150px; background: black; color: white;" colspan=2 |'''Value range''' | ! style="width: 150px; background: black; color: white;" colspan=2 |'''Value range''' | ||
! style="width: 150px; background: black; color: white;" rowspan=2 |'''Value''' | ! style="width: 150px; background: black; color: white;" rowspan=2 |'''Value''' | ||
Revision as of 10:31, 22 August 2018
Green driving parameters
| Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 1890 | Uint8 | - | 0 | 1 | 0 – Disable | Scenario settings |
| 1 – Enable | ||||||
| 1891 | Uint8 | - | 0 | 2 | 0 - disable | Digital Output Control |
| 1 - DOUT1 | ||||||
| 2 - DOUT2 | ||||||
| 1909 | Uint8 | - | 0 | 1 | 0 - GPS | Source |
| 1 - Accelerometer | ||||||
| 1892 | Float | 0.25 | 0.25 | 0.85 | mG | Max Acceleration Force |
| 1893 | Float | 0.35 | 0.25 | 0.85 | mG | Max Braking Force |
| 1894 | Float | 0.2 | 0.1 | 1.0 | mG | Max Cornering Force |
Overspeeding scenario parameters
| Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 1895 | Uint8 | 0 | 0 | 1 | 0 – Disable | Scenario settings |
| 1 – Enable | ||||||
| 1896 | Uint8 | - | 0 | 2 | 0 – None | Digital Output control |
| 1 – DOUT 1 | ||||||
| 2 – DOUT 2 | ||||||
| 1897 | Uint16 | - | 0 | 260 | km/h | Max speed |
Jamming scenario parameters
| Parameter ID | Parameter Type | Recommended Value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 1898 | Uint8 | - | 0 | 1 | 0 – Disable | Scenario settings |
| 1 – Enable | ||||||
| 1899 | Uint8 | - | 0 | 2 | 0 – None | Digital Output control |
| 1 – DOUT1 | ||||||
| 2 – DOUT2 | ||||||
| 1900 | Uint8 | - | 0 | 2 | 0 – Low sensitivity (50 RSSI) | Jamming sensitivity |
| 1 – Medium sensitivity (30 RSSI) | ||||||
| 2 – High sensitivity (10 RSSI) | ||||||
| 1901 | Uint16 | 60 | 0 | 65535 | Seconds | Jamming Timeout |
| 1902 | Uint16 | 0 | 0 | 65535 | Seconds | Jamming Pulse Duration |
Immobilizer scenario parameters
| Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 1903 | Uint8 | - | 0 | 1 | 0 – Disable | Scenario settings |
| 1 – Enable | ||||||
| 1904 | Uint8 | - | 0 | 2 | 0 – Disable | Digital Output Control |
| 1 – DOUT1 | ||||||
| 2 – DOUT2 | ||||||
iButton read notification
| Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 11704 | Uint8_t | 0 | 0 | 1 | 0 - Disabled | DOUT control |
| 1 - Enabled | ||||||
| 11705 | Uint16_t | 200 | 100 | 50000 | Milliseconds | DOUT duration |
| 11706 | Uint8_t | 0 | 0 | 1 | 0 - Disabled | iButton notification list |
| 1 - Enabled | ||||||
| 11707 | Uint8_t | 0 | 0 | 1 | 0 - Disabled | Depend on ignition |
| 1 - Enabled | ||||||
Trip scenario parameters
| Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 11800 | Uint8 | 0 | 0 | 3 | 0 – Disable | Scenario settings |
| 1 – Low priority | ||||||
| 2 – High priority | ||||||
| 3 – Panic priority | ||||||
| 11801 | Uint8 | 1 | 0 | 1 | 0 – Disable | Eventual records |
| 1 – Enable | ||||||
| 11802 | Uint8 | 0 | 0 | 1 | 0 – Continuous | Mode |
| 1 – Between records | ||||||
| 11803 | Uint8 | 5 | 0 | 255 | km/h | Start speed |
| 11804 | Uint16 | 60 | 0 | 65535 | Seconds | Ignition off timeout |
| 7031 | Uint8 | 0 | 0 | 10 | Phone number | Send SMS to |
| 8031 | String | "Trip" | 0 | 160 | Text | Sms text |
DOUT control via call scenario parameters
| Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 12000 | Uint8 | 0 | 0 | 2 (1 for FMB125) | 0 – None | Digital Output control |
| 1 – DOUT 1 | ||||||
| 2 – DOUT 2 | ||||||
| 12001 | Uint8 | 0 | 0 | 3 (1 for FMB125) | 0 – None | DOUT deactivation |
| 1 – DIN 1 | ||||||
| 2 – DIN 2 | ||||||
| 3 – DIN 3 | ||||||
| 12002 | Int32 | 5 | 0 | 2147483647 | Seconds | Duration timeout |