Main Page > EOL Products > FMA120 > FMA120 Manual > FMA120 General descriptionFMA120 is a tracking terminal with GNSS and GSM connectivity, which is able to collect device coordinates and transfer them via GSM network to a server. This device is perfectly suitable for applications, which require the location acquirement of remote objects.
Technical features
| Part name | Physical specification |
|---|---|
| Navigation indication | LED |
| Modem indication | LED |
| Socket 2x5 | Tyco Micro MATE-N-LOK™ 4-794628-0 or similar |
| USB | Mini USB socket |
| GNSS | Internal GNSS antenna |
| GSM | Internal GSM antenna |
| Technical details | |
|---|---|
| 2 W max. Current consumption at 12 V |
GPRS: average 120 mA rms Nominal: average 65 mA rms GNSS sleep: average 28 mA Deep Sleep: average 5 mA² |
| Battery charge current | Average 115 mA |
| Operating temperature (without battery) | -40°C..+85 °C |
| Operating temperature (without battery) | -40°C..+85 °C |
| Storage relative humidity | 5..95% (no condensation) |
| Internal fuse | 3A, 125V |
Dimension drawing:

Technical information about internal battery
| Internal back-up battery | Battery voltage (V) | Nominal Capacity (mAh) | Power (Wh) | Charge temperature (°C) | Discharge temperature (°C) | Storage temperature (°C) |
|---|---|---|---|---|---|---|
| Li-ion rechargeable battery | 3.75~3.90 | 170 | 0.64 – 0.66 | 0 to +45 | -20 to +60 | -20 to +45 for 1 month -20 to +35 for 6 months |
Batteries are covered by 6 month warranty support.
Electrical characteristics
| Characteristic description | Value | |||
|---|---|---|---|---|
| Min. | Typ. | Max. | Unit | |
| Supply Voltage: | ||||
| Supply Voltage (Recommended Operating Conditions) | 5 | 30 | V | |
| Digital Input: | ||||
| Input resistance (DIN1) | 120 | kOhm | ||
| Input resistance (DIN2, DIN3) | 15 | kOhm | ||
| Input Voltage (Recommended Operating Conditions) | 0 | Supply voltage | V | |
| Input Voltage threshold (DIN1) | 7.5 | V | ||
| Input Voltage threshold (DIN2, DIN3) | 2.6 | V | ||
| Digital Output (Open Drain grade): | ||||
| Drain Current (Digital Output OFF) | 120 | uA | ||
| Drain Current (Digital Output ON, Recommended Operating Conditions) | 300 | mA | ||
| Static Drain-Source Resistance (Digital Output ON) | 300 | mOhm | ||
| Analog Input: | ||||
| Input voltage (Recommended Operating Conditions), Range 1 | 0 | 10 | V | |
| Input resistance, Range 1 | 120 | kOhm | ||
| Measurement error | 4.4 | % | ||
| Additional error | ±26 | mV | ||
| Input Voltage (Recommended Operating Conditions) Range2 | 0 | 30 | V | |
| Input resistance, Range2 | 146.7 | kOhm | ||
| Measurement error | 4 | % | ||
| Additional error | ±40 | mV | ||
| Output Supply Voltage 1-Wire:³ | ||||
| Supply voltage | 3.3 | 3.6 | V | |
| Output inner resistance | 10 | Ohm | ||
| Output current (Uout > 3.0 V) | 30 | mA | ||
| Short circuit current (Uout = 0) | 130 | mA | ||
Absolute Maximum Ratings
| Characteristic description | Value | |||
|---|---|---|---|---|
| Min. | Typ. | Max. | Unit | |
| Supply Voltage (Absolute Maximum Ratings) | -32 | 32 | V | |
| Drain-Source clamp threshold voltage (Absolute Maximum Ratings), (Idrain = 2mA) | 36 | V | ||
| Digital Input Voltage (Absolute Maximum Ratings) | -32 | 32 | V | |
| Analog Input Voltage (Absolute Maximum Ratings) | -32 | 32 | V | |