Template:FMA120Package contents

Basic characteristics

GSM / GPRS features:

  • Quad band supported (GSM 850 / 900 / 1800 / 1900 MHz);
  • GPRS Multi-Slot Class 12(up to 240 kbps);
  • GPRS Mobile Station Class B;
  • SMS (text, data).


GNSS features:

  • Tracking: 33/ 99 acquisition channels;
  • Up to -165 dBm sensitivity;
  • Hot start < 1s;
  • Warm start < 25s;
  • Cold start < 35s;
  • NMEA -183 protocol;
  • GPS, GLONASS, GALILEO, BEIDOU, SBAS, QZSS, DGPS, AGPS;
  • Accuracy < 3m.


Hardware features:

  • Cortex®-M3 processor;
  • 1 MB internal Flash memory;
  • Built-in accelerometer.


Interface features:

  • Power supply: 10 ÷ 30V;
  • USB port;
  • 3 digital inputs;
  • 1 analog input;
  • 2 open collector digital outputs;
  • 1Wire® temperature sensor
  • 1Wire® iButton
  • LEDs indicating device status.


Special features:

  • Any element event triggers (external sensor, input, speed, temperature, etc.);
  • Highly configurable data acquisition and sending;
  • Multiple Geo-fence areas;
  • Sleep mode;
  • Deep sleep mode;
  • Configurable scenarios available;
  • Real-time process monitoring;
  • Authorized number list for remote access;
  • Firmware update over GPRS or USB port;
  • Configuration update over GPRS, SMS or USB port;
  • TCP/IP or UDP/IP protocol support;
  • 3500 record storing.


Template:FMB Supply voltage

Technical features

Part name Physical specification
Navigation indication LED
Modem indication LED
Socket 2x5 Tyco Micro MATE-N-LOK™ 4-794628-0 or similar
USB Mini USB socket
GNSS Internal GNSS antenna
GSM Internal GSM antenna
Technical details
2 W max.
Current consumption at 12 V
GPRS: average 120 mA rms
Nominal: average 65 mA rms
GNSS sleep: average 28 mA
Deep Sleep: average 5 mA²
Battery charge current Average 115 mA
Operating temperature -25°C..+55 °C
Storage temperature -40°C..+70 °C
Storage relative humidity 5..95% (no condensation)
Internal fuse 3A, 125V

Dimension drawing:

Fmb120 view dims.png