Green driving parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1890 | Uint8 | - | 0 | 1 | 0 – Disable | Scenario settings |
1 – Enable | ||||||
1891 | Uint8 | - | 0 | 2 | 0 - disable | Digital Output Control |
1 - DOUT1 | ||||||
2 - DOUT2 | ||||||
1909 | Uint8 | - | 0 | 1 | 0 - GPS | Source |
1 - Accelerometer | ||||||
1892 | Float | 0.25 | 0.25 | 0.85 | mG | Max Acceleration Force |
1893 | Float | 0.35 | 0.25 | 0.85 | mG | Max Braking Force |
1894 | Float | 0.2 | 0.1 | 1.0 | mG | Max Cornering Force |
Overspeeding scenario parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1895 | Uint8 | 0 | 0 | 1 | 0 – Disable | Scenario settings |
1 – Enable | ||||||
1896 | Uint8 | - | 0 | 2 | 0 – None | Digital Output control |
1 – DOUT 1 | ||||||
2 – DOUT 2 | ||||||
1897 | Uint16 | - | 0 | 260 | km/h | Max speed |
Jamming scenario parameters
Parameter ID | Parameter Type | Recommended Value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1898 | Uint8 | - | 0 | 1 | 0 – Disable | Scenario settings |
1 – Enable | ||||||
1899 | Uint8 | - | 0 | 2 | 0 – None | Digital Output control |
1 – DOUT1 | ||||||
2 – DOUT2 | ||||||
1900 | Uint8 | - | 0 | 2 | 0 – Low sensitivity (50 RSSI) | Jamming sensitivity |
1 – Medium sensitivity (30 RSSI) | ||||||
2 – High sensitivity (10 RSSI) | ||||||
1901 | Uint16 | 60 | 0 | 65535 | Seconds | Jamming Timeout |
1902 | Uint16 | 0 | 0 | 65535 | Seconds | Jamming Pulse Duration |
Immobilizer scenario parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1903 | Uint8 | - | 0 | 1 | 0 – Disable | Scenario settings |
1 – Enable | ||||||
1904 | Uint8 | - | 0 | 2 | 0 – Disable | Digital Output Control |
1 – DOUT1 | ||||||
2 – DOUT2 | ||||||
1905 | Uint8 | - | 0 | 1 | 0 – Disable | iButton list checking |
1 – Enable | ||||||
1906 | Uint16 | 30 | 5 | 65353 | Seconds | Ignition Off Timeout |
iButton read notification
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1907 | Uint8 | - | 0 | 1 | 0 - Disabled | iButton detect |
1 - Enabled | ||||||
1908 | Uint8_t | 0 | 0 | 1 | 0 - Disabled | Digital Output Control |
1 - DOUT1 | ||||||
2 - DOUT2 |
Trip scenario parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1280 | Uint8 | - | 0 | 1 | 0 – Disable | Scenario settings |
1 – Enable | ||||||
1281 | Uint8 | - | 0 | 255 | km/h | Start speed |
1282 | Uint16 | - | 0 | 65535 | Seconds | Ignition off timeout |
1283 | Uint8 | - | 0 | 1 | 0 – Not | Continuous distance counting |
1 – Continuous | ||||||
1284 | Uint8 | - | 0 | 1 | 0 – Disable | Remember iButton ID |
1 – Enable | ||||||
1285 | Uint8 | - | 0 | - | Meters | Odometer Value |