FMB firmware errata: Difference between revisions

From Teltonika Telematics Wiki
(Created page with "==FMBXXX Firmware Errata== __TOC__ ===Introduction=== We are always improving our devices performance, stability and reliability. That’s why Teltonika is one of the leading...")
 
No edit summary
Line 3: Line 3:
===Introduction===
===Introduction===
We are always improving our devices performance, stability and reliability. That’s why Teltonika is one of the leading GNSS trackers manufacturers in the world.<br \>
We are always improving our devices performance, stability and reliability. That’s why Teltonika is one of the leading GNSS trackers manufacturers in the world.<br \>
This document describes '''FMB(T)XXX<ref>FMB(T)XXX – FMB9, FMB96, FMB0, FMB1, FMB2, FM30XY, FMT100. Except FMB630.</ref>''' devices firmware improvements, changes, new features implementations as well as current firmware release version.
This document describes '''FMB(T)XXX<ref>FMB(T)XXX – FMB9, FMB96, FMB0, FMB1, FMB2, FM30XY, FMT100. Except FMB630, FMB640.</ref>''' devices firmware improvements, changes, new features implementations as well as current firmware release version.


{| class="wikitable" style="width: 60%;"
{| class="wikitable" style="width: 60%;"

Revision as of 14:22, 6 November 2018

FMBXXX Firmware Errata

Introduction

We are always improving our devices performance, stability and reliability. That’s why Teltonika is one of the leading GNSS trackers manufacturers in the world.
This document describes FMB(T)XXX<ref>FMB(T)XXX – FMB9, FMB96, FMB0, FMB1, FMB2, FM30XY, FMT100. Except FMB630, FMB640.</ref> devices firmware improvements, changes, new features implementations as well as current firmware release version.

FIRMWARE VERSION SUPPORTED HARDWARE
01.00.XX FMB0YX, FMB9X0
01.01.XX FMB0YX, FMB9X0, FMB96X
01.03.XX FMB0YX, FMB9X0, FMB96X
03.01.XX FMB0YX, FMB9X0, FMB96X, FMB1YX
03.02.XX FMB0YX, FMB9X0, FMB96X, FMB1YX
03.06.XX FMB0YX, FMB9X0, FMB96X, FMB1YX, FM30XY
03.07.XX FMB0YX, FMB9X0, FMB96X, FMB1YX, FM30XY, FMB2YX
03.18.XX FMB0YX, FMB9X0, FMB96X, FMB1YX, FM30XY, FMB2YX, FMT100

Firmware versioning

  • Structure
FMB(T).VER.[XX].[YY].[ZZ].Rev.[##] _[ID###]
  • Sytanx description
    • XX – major FW version.
    • YY – branch number, shows major changes in firmware, i.e. new module support added or new major feature added.
    • ZZ – major changes like bigger fixes, improvements and new features addition.
    • ## – minor changes like small fixes and improvements.
    • ID[###] – Spec ID KEY – Specific clients FW changes

Firmware versions

FIRMWARE VERSION RELEASE DATE CHANGES
03.18.03.Rev.00
(recommended for FMB900)
2018.09.25
  • Fixed AIN1 and External Voltage swap for FMB900
03.18.02.Rev.00 2018.09.24
  • Added shadow calibration functionality
  • Improved eco driving events functionality
  • Improved GNSS hdop&pdop validation
  • Fixed LVCAN Fuel Level value coefficient according to IO protocol
  • Added Battery level % IO element