Difference between revisions of "FMM640 Accessories"
From Wiki Knowledge Base | Teltonika GPS
m (Protected "FMM640 Accessories" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite))) |
|
(No difference)
|
Revision as of 12:35, 2 September 2019
Main Page > EOL Products > FMM640 > FMM640 Manual > FMM640 AccessoriesPlease order accessories separately as they are not included into device package. |
Accessory and its description | Accessory connection schematic |
---|---|
Fuel tank sensors | Fuel sensor connection to FMM640 |
A fuel tank level sensor which indicates the approximate fuel level on the driver's indicator panel exists in most cars. If the sensor returns analogue signal proportional to fuel level it can be connected to FMM640 Analog input. After connection to the tank fuel level sensor a calibration is needed because most fuel tank sensors are not linear. Calibration is performed by measuring voltage values resulting from the volume of fuel in tank. | |
Alarm buttons, door sensors etc. | Panic button connection to FMM640 |
Alarm buttons, door sensors, ignition, etc. have two output states: high or low. FMM640 Digital inputs are used to detect these states. | |
Relays | Inverting relay connection to FMM640 |
In cases when sensor output signal is negative, an additional relay has to be installed to convert negative signal to positive. | |
Immobilizer relay | Immobilizer relay connection to FMM640 output |
When connected as shown on the right hand side, FMM640 disables engine starter when output is ON. | |
Automotive relay | Automotive relay pinout |
An ordinary automotive relay is used to invert input signal or to immobilize engine starter. Note that relays can be 12 V or 24 V capable. |
|
1-Wire devices | Digital thermometer DS1820 and TTJ100 connection to FMM640 |
One of the implemented features on FMM640 is 1-Wire® data protocol, which enables connection to devices such as thermometer (DS1820, DS18S20 and DS18B20) and I-Button DS1990A. | |
TTJ sensor pinout | |
I-Button DS1990A connection to FMM640 | |
Impulse counters | Pulse fuel meters connection scheme |
Here two pulse meters are used, where one is mounted on the direct flow valve and the other on the return flow valve. Data from both meters is sent to the FMM640. Then FMM640 calculates DIN3-DIN4. Resulting difference equals to fuel consumption. Filter should be used on the direct flow pipe to prevent any damage caused by impurities in the liquid. The filter mounted in the meter inlet is only a safety filter and it is too small to act as a strainer. Read more about impulse counters here |