Difference between revisions of "FMM001 firmware errata"
(Created page with "{{Template:FMB_AVL_ID | name = FMM001 AVL ID }} Category:FMM001") |
m (Protected "FMM001 firmware errata" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite))) |
(No difference)
|
Revision as of 08:03, 17 October 2019
Main Page > EOL Products > FMM001 > FMM001 firmware errataDocument updated according firmware FMB.Ver.03.29.00 and newer.
FMB AVL ID's consist of these parameters groups:
Permanent I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
239 | Ignition | 1 | Unsigned | 0 | 1 | - | - |
0 – Ignition Off |
Permanent I/O Elements | |
240 | Movement | 1 | Unsigned | 0 | 1 | - | - |
0 – Movement Off |
Permanent I/O elements | |
80 | Data Mode | 1 | Unsigned | 0 | 5 | - | - |
0 – Home On Stop |
Permanent I/O Elements | |
21 | GSM Signal | 1 | Unsigned | 0 | 5 | - | - |
Value in range 1-5 Explanation |
Permanent I/O Elements | |
200 | Sleep Mode | 1 | Unsigned | 0 | 4 | - | - |
0 - No Sleep |
Permanent I/O Elements | |
69 | GNSS Status | 1 | Unsigned | 0 | 3 | - | - |
0 - GNSS OFF |
Permanent I/O Elements | |
181 | GNSS PDOP | 2 | Unsigned | 0 | 500 | 0.1 | Coefficient, calculation formula | Permanent I/O Elements | ||
182 | GNSS HDOP | 2 | Unsigned | 0 | 500 | 0.1 | Coefficient, calculation formula | Permanent I/O Elements | ||
66 | External Voltage | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Voltage |
Permanent I/O elements | |
24 | Speed | 2 | Unsigned | 0 | 350 | - | km/h |
GNSS Speed |
Permanent I/O elements | |
205 | GSM Cell ID | 2 | Unsigned | 0 | 65535 | - | - |
GSM base station ID |
Permanent I/O elements | |
206 | GSM Area Code | 2 | Unsigned | 0 | 65535 | - | - |
Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations. |
Permanent I/O elements | |
67 | Battery Voltage | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Voltage |
Permanent I/O elements | |
68 | Battery Current | 2 | Unsigned | 0 | 65535 | 0.001 | A |
Current |
Permanent I/O elements | |
241 | Active GSM Operator | 4 | Unsigned | 0 | 4294967295 | - | - |
Currently used GSM Operator code |
Permanent I/O elements | |
199 | Trip Odometer | 4 | Unsigned | 0 | 2147483647 | - | m |
Trip Odometer value |
Permanent I/O elements | |
16 | Total Odometer | 4 | Unsigned | 0 | 2147483647 | - | - |
Total Odometer value in meters |
Permanent I/O elements | |
1 | Digital Input 1 | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
9 | Analog Input 1 | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Voltage |
Permanent I/O elements | |
179 | Digital Output 1 | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
12 | Fuel Used GPS | 4 | Unsigned | 0 | 4294967295 | 0.001 | l |
Fuel Used |
Permanent I/O elements | |
13 | Fuel Rate GPS | 2 | Unsigned | 0 | 32767 | 0.01 | l/100km |
Average Fuel Use |
Permanent I/O elements | |
17 | Axis X | 2 | Signed | -8000 | 8000 | - | mG |
X axis value |
Permanent I/O elements | |
18 | Axis Y | 2 | Signed | -8000 | 8000 | - | mG |
Y axis value |
Permanent I/O elements | |
19 | Axis Z | 2 | Signed | -8000 | 8000 | - | mG |
Z axis value |
Permanent I/O elements | |
11 | ICCID1 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - |
Value of SIM ICCID, MSB |
Permanent I/O elements | |
10 | SD Status | 1 | Unsigned | 0 | 1 | - | - |
0 - not present 1 - present |
Permanent I/O elements | |
2 | Digital Input 2 | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
3 | Digital Input 3 | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
6 | Analog Input 2 | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Voltage |
Permanent I/O elements | |
180 | Digital Output 2 | 1 | Unsigned | 0 | 1 | - | - | Logic 0/1 | Permanent I/O elements | |
72 | Dallas Temperature 1 | 4 | Signed | -550 | 1150 | 0.1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
Permanent I/O elements | |
73 | Dallas Temperature 2 | 4 | Signed | -550 | 1150 | 0.1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
Permanent I/O elements | |
74 | Dallas Temperature 3 | 4 | Signed | -550 | 1150 | 0.1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
Permanent I/O elements | |
75 | Dallas Temperature 4 | 4 | Signed | -550 | 1150 | 0.1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
Permanent I/O elements | |
76 | Dallas Temperature ID 1 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | Permanent I/O elements | |
77 | Dallas Temperature ID 2 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | Permanent I/O elements | |
79 | Dallas Temperature ID 3 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | Permanent I/O elements | |
71 | Dallas Temperature ID 4 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | Permanent I/O elements | |
78 | iButton | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | iButton ID | Permanent I/O elements | |
207 | RFID | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | RFID ID | Permanent I/O elements | |
201 | LLS 1 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS232/RS485 | Permanent I/O elements | |
202 | LLS 1 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS232/RS485 | Permanent I/O elements | |
203 | LLS 2 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS485 | Permanent I/O elements | |
204 | LLS 2 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS485 | Permanent I/O elements | |
210 | LLS 3 Fuel Level | 2 | Unsigned | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS485 | Permanent I/O elements | |
211 | LLS 3 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS485 | Permanent I/O elements | |
212 | LLS 4 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS485 | Permanent I/O elements | |
213 | LLS 4 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS485 | Permanent I/O elements | |
214 | LLS 5 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS485 | Permanent I/O elements | |
215 | LLS 5 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS485 | Permanent I/O elements | |
15 | Eco Score | 2 | Unsigned | 0 | 65535 | 0.01 | - | Average amount of events on some distance | Permanent I/O elements | |
113 | Battery Level | 1 | Unsigned | 0 | 100 | - | % | Battery capacity level | Permanent I/O elements | |
238 | User ID | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | MAC address of NMEA receiver device connected via Bluetooth | Permanent I/O elements | |
237 | Network Type | 1 | Unsigned | 0 | 1 | - | - | 0 - 3G
1 - GSM |
Permanent I/O elements | |
4 | Pulse Counter Din1 | 4 | Unsigned | 0 | 4294967295 | - | - | Counts pulses, count is reset when records are saved | Permanent I/O elements | |
5 | Pulse Counter Din2 | 4 | Unsigned | 0 | 4294967295 | - | - | Counts pulses, count is reset when records are saved | Permanent I/O elements | |
263 | BT Status | 1 | Unsigned | 0 | 4 | - | - | 0 - BT is disabled
1 - BT Enabled, not device connected 2 - Device connected, BTv3 Only 3 - Device connected, BLE only 4 - Device connected, BLE + BT |
Permanent I/O elements | |
264 | Barcode ID | Variable | ASCII | 0 | 32 | - | - | Barcode ID | ||
303 | Instant Movement | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 returns movement value | Permanent I/O elements | |
327 | UL202-02 Sensor Fuel level | 2 | Signed | -150 | 32767 | 0.1 | mm | UL202-02 Sensor Fuel level | Permanent I/O elements | |
483 | UL202-02 Sensor Status | 1 | Unsigned | 0 | 255 | - | - | UL202-02 sensor status codes | Permanent I/O elements | |
380 | Digital output 3 | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | Permanent I/O elements | |
381 | Ground Sense | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | FMB130 |
Permanent I/O elements |
387 | ISO6709 Coordinates | 34 | HEX | 0 | 0x7fffffffffffffff | - | - | ISO6709 Coordinates
Latitude, Longitude (in Degrees, Minutes and Seconds) and Altitude: IO value format: ±DDMMSS.SSSS±DDDMMSS.SSSS±AAA.AAA/ |
Permanent I/O elements | |
636 | UMTS/LTE Cell ID | 4 | Unsigned | 0 | 0xFFFFFFFF | - | - | Permanent I/O elements | ||
403 | Driver Name | 35 | Unsigned | - | - | - | - | Driver name extracted from card, displayed without delimiters ($ signs) |
FMBXXX FMU126
|
Permanent I/O elements |
404 | Driver card license type | 1 | Unsigned | 0 | 8 | - | - |
None - 0 |
FMBXXX FMU126
|
Permanent I/O elements |
405 | Driver Gender | 1 | Unsigned | 0 | 2 | - | - |
None - 0 |
FMBXXX FMU126
|
Permanent I/O elements |
406 | Driver Card ID | 4 | Unsigned | 0 | 4294967295 | - | - |
None - 0 |
FMBXXX FMU126
|
Permanent I/O elements |
407 | Driver card expiration date | 1 | Unsigned | 0 | 9999 | - | - |
FMBXXX FMU126
|
Permanent I/O elements | |
408 | Driver Card place of issue | 4 | Unsigned | 0 | 65535 | - | - | Extracted from card |
FMBXXX FMU126
|
Permanent I/O Elements |
409 | Driver Status Event | 1 | Unsigned | 0 | 2 | - | - |
Registered - 0 |
FMBXXX FMU126
|
Permanent I/O elements |
329 | AIN Speed | 2 | Unsigned | 0 | 65535 | - | - | MSP500 | Permanent I/O elements | |
500 | MSP500 vendor name | 40 | ASCII | 0 | 40 | - | - | Name of the integrator who installed the device | MSP500 | Permanent I/O elements |
501 | MSP500 vehicle number | 40 | ASCII | 0 | 40 | - | - | Vehicle number on which the device is installed | MSP500 | Permanent I/O elements |
502 | MSP500 speed sensor | 1 | unsigned | 0 | 1 | - | - | Status of the speed sensor | MSP500 | Permanent I/O elements |
637 | Wake Reason | 1 | Unsigned | 0 | 1 | - | - |
True if device was woken by RTC alarm |
Permanent I/O elements | |
10800 | EYE Temperature 1 | 2 | Signed | -32768 | 32767 | 0.01 | °C | Temperature measured by EYE Sensor 1 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10801 | EYE Temperature 2 | 2 | Signed | -32768 | 32767 | 0.01 | °C | Temperature measured by EYE Sensor 2 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10802 | EYE Temperature 3 | 2 | Signed | -32768 | 32767 | 0.01 | °C | Temperature measured by EYE Sensor 3 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10803 | EYE Temperature 4 | 2 | Signed | -32768 | 32767 | 0.01 | °C | Temperature measured by EYE Sensor 4 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10804 | EYE Humidity 1 | 1 | Unsigned | 0 | 100 | - | % | Humidity measured by EYE Sensor 1 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10805 | EYE Humidity 2 | 1 | Unsigned | 0 | 100 | - | % | Humidity measured by EYE Sensor 2 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10806 | EYE Humidity 3 | 1 | Unsigned | 0 | 100 | - | % | Humidity measured by EYE Sensor 3 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10807 | EYE Humidity 4 | 1 | Unsigned | 0 | 100 | - | % | Humidity measured by EYE Sensor 4 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10808 | EYE Magnet 1 | 1 | Unsigned | 0 | 1 | - | - | Magnet measured by EYE Sensor by EYE Sensor 1 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10809 | EYE Magnet 2 | 1 | Unsigned | 0 | 1 | - | - | Magnet measured by EYE Sensor by EYE Sensor 2 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10810 | EYE Magnet 3 | 1 | Unsigned | 0 | 1 | - | - | Magnet measured by EYE Sensor by EYE Sensor 3 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10811 | EYE Magnet 4 | 1 | Unsigned | 0 | 1 | - | - | Magnet measured by EYE Sensor by EYE Sensor 4 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10812 | EYE Movement 1 | 1 | Unsigned | 0 | 1 | - | - | Movement state measure by EYE Sensor 1 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10813 | EYE Movement 2 | 1 | Unsigned | 0 | 1 | - | - | Movement state measure by EYE Sensor 2 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10814 | EYE Movement 3 | 1 | Unsigned | 0 | 1 | - | - | Movement state measure by EYE Sensor 3 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10815 | EYE Movement 4 | 1 | Unsigned | 0 | 1 | - | - | Movement state measure by EYE Sensor 4 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10816 | EYE Pitch 1 | 1 | Signed | -90 | 90 | - | - | Pitch angle measured by EYE Sensor 1 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10817 | EYE Pitch 2 | 1 | Signed | -90 | 90 | - | - | Pitch angle measured by EYE Sensor 2 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10818 | EYE Pitch 3 | 1 | Signed | -90 | 90 | - | - | Pitch angle measured by EYE Sensor 3 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10819 | EYE Pitch 4 | 1 | Signed | -90 | 90 | - | - | Pitch angle measured by EYE Sensor 4 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10820 | EYE Low Battery 1 | 1 | Unsigned | 0 | 1 | - | - | Low Battery indication for EYE Sensor 1 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10821 | EYE Low Battery 2 | 1 | Unsigned | 0 | 1 | - | - | Low Battery indication for EYE Sensor 2 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10822 | EYE Low Battery 3 | 1 | Unsigned | 0 | 1 | - | - | Low Battery indication for EYE Sensor 3 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10823 | EYE Low Battery 4 | 1 | Unsigned | 0 | 1 | - | - | Low Battery indication for EYE Sensor 4 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10824 | EYE Battery Voltage 1 | 2 | Unsigned | 0 | 65535 | - | - | Battery Voltage of EYE Sensor 1 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10825 | EYE Battery Voltage 2 | 2 | Unsigned | 0 | 65535 | - | - | Battery Voltage of EYE Sensor 2 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10826 | EYE Battery Voltage 3 | 2 | Unsigned | 0 | 65535 | - | - | Battery Voltage of EYE Sensor 3 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10827 | EYE Battery Voltage 4 | 2 | Unsigned | 0 | 65535 | - | - | Battery Voltage of EYE Sensor 4 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10832 | EYE Roll 1 | 2 | Signed | -180 | 180 | - | - | Roll angle measured by EYE Sensor 1 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10833 | EYE Roll 2 | 2 | Signed | -180 | 180 | - | - | Roll angle measured by EYE Sensor 2 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10834 | EYE Roll 3 | 2 | Signed | -180 | 180 | - | - | Roll angle measured by EYE Sensor 3 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10835 | EYE Roll 4 | 2 | Signed | -180 | 180 | - | - | Roll angle measured by EYE Sensor 4 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10836 | EYE Movement count 1 | 2 | Unsigned | 0 | 32767 | - | - | Movement count measure by EYE Sensor 1 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10837 | EYE Movement count 2 | 2 | Unsigned | 0 | 32767 | - | - | Movement count measure by EYE Sensor 2 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10838 | EYE Movement count 3 | 2 | Unsigned | 0 | 32767 | - | - | Movement count measure by EYE Sensor 3 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10839 | EYE Movement count 4 | 2 | Unsigned | 0 | 32767 | - | - | Movement count measure by EYE Sensor 4 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10840 | EYE Magnet count 1 | 2 | Unsigned | 0 | 65535 | - | - | Magnet trigger count measure by EYE Sensor 1 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10841 | EYE Magnet count 2 | 2 | Unsigned | 0 | 65535 | - | - | Magnet trigger count measure by EYE Sensor 2 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10842 | EYE Magnet count 3 | 2 | Unsigned | 0 | 65535 | - | - | Magnet trigger count measure by EYE Sensor 3 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
10843 | EYE Magnet count 4 | 2 | Unsigned | 0 | 65535 | - | - | Magnet trigger count measure by EYE Sensor 4 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 |
Permanent I/O elements |
383 | AXL Calibration Status | 1 | Unsigned | 0 | 3 | - | - | Shows calibration status: 0- no calibration, 1- calibrated, 2- not configured, 3- fully calibrated |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 FMB910 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
451 | BLE RFID #1 | 8 | HEX | 0 | 0xffffffffffffffff | - | - | BLE NBL-T RFID ID for Connetionless mode #1 slot |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 FMP100 FMP1M1 MSP500 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
452 | BLE RFID #2 | 8 | HEX | 0 | 0xffffffffffffffff | - | - | BLE NBL-T RFID ID for Connetionless mode #2 slot |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 FMP100 FMP1M1 MSP500 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
453 | BLE RFID #3 | 8 | HEX | 0 | 0xffffffffffffffff | - | - | BLE NBL-T RFID ID for Connetionless mode #3 slot |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 FMP100 FMP1M1 MSP500 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
454 | BLE RFID #4 | 8 | HEX | 0 | 0xffffffffffffffff | - | - | BLE NBL-T RFID ID for Connetionless mode #4 slot |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 FMP100 FMP1M1 MSP500 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
455 | BLE Button 1 state #1 | 1 | Unsigned | 0 | 1 | - | - | BLE NBL-T Button 1 status for Connetionless mode #1 slot |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 FMP100 FMP1M1 MSP500 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
456 | BLE Button 1 state #2 | 1 | Unsigned | 0 | 1 | - | - | BLE NBL-T Button 1 status for Connetionless mode #2 slot |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 FMP100 FMP1M1 MSP500 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
457 | BLE Button 1 state #3 | 1 | Unsigned | 0 | 1 | - | - | BLE NBL-T Button 1 status for Connetionless mode #3 slot |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 FMP100 FMP1M1 MSP500 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
458 | BLE Button 1 state #4 | 1 | Unsigned | 0 | 1 | - | - | BLE NBL-T Button 1 status for Connetionless mode #4 slot |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 FMP100 FMP1M1 MSP500 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
459 | BLE Button 2 state #1 | 1 | Unsigned | 0 | 1 | - | - | BLE NBL-T Button 2 status for Connetionless mode #1 slot |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 FMP100 FMP1M1 MSP500 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
460 | BLE Button 2 state #2 | 1 | Unsigned | 0 | 1 | - | - | BLE NBL-T Button 2 status for Connetionless mode #2 slot |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 FMP100 FMP1M1 MSP500 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
461 | BLE Button 2 state #3 | 1 | Unsigned | 0 | 1 | - | - | BLE NBL-T Button 2 status for Connetionless mode #3 slot |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 FMP100 FMP1M1 MSP500 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
462 | BLE Button 2 state #4 | 1 | Unsigned | 0 | 1 | - | - | BLE NBL-T Button 2 status for Connetionless mode #4 slot |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 FMP100 FMP1M1 MSP500 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
622 | Frequency DIN1 | 2 | Unsigned | 0 | 65535 | 0.1 | Hz | Frequency of input signal present on DIN1 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 FMP100 FMP1M1 MSP500 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
623 | Frequency DIN2 | 2 | Unsigned | 0 | 65535 | 0.1 | Hz | Frequency of input signal present on DIN2 |
FMBXXX [Expand] FMB001 FMB010 FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB900 FMB920 FMB962 FMB964 FM3001 FM3010 FMB202 FMB204 FMB206 FMB207 FMB208 FMB209 FMT100 MTB100 TMT250 GH5200 FMB140 FMB020 FMB002 FMB003 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMC001 FMM001 TFT100 FMB910 FMP100 FMP1M1 MSP500 FMC800 FMM800 FMC880 FMM880 FMM80A |
Permanent I/O elements |
Eventual I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
155 | Geofence zone 01 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
156 | Geofence zone 02 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
157 | Geofence zone 03 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
158 | Geofence zone 04 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
159 | Geofence zone 05 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
61 | Geofence zone 06 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
62 | Geofence zone 07 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
63 | Geofence zone 08 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
64 | Geofence zone 09 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
65 | Geofence zone 10 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
70 | Geofence zone 11 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
88 | Geofence zone 12 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
91 | Geofence zone 13 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
92 | Geofence zone 14 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
93 | Geofence zone 15 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
94 | Geofence zone 16 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
95 | Geofence zone 17 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
96 | Geofence zone 18 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
97 | Geofence zone 19 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
98 | Geofence zone 20 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
99 | Geofence zone 21 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
153 | Geofence zone 22 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
154 | Geofence zone 23 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
190 | Geofence zone 24 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
191 | Geofence zone 25 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
192 | Geofence zone 26 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
193 | Geofence zone 27 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
194 | Geofence zone 28 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
195 | Geofence zone 29 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
196 | Geofence zone 30 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
197 | Geofence zone 31 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
198 | Geofence zone 32 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
208 | Geofence zone 33 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
209 | Geofence zone 34 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
216 | Geofence zone 35 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
217 | Geofence zone 36 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
218 | Geofence zone 37 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
219 | Geofence zone 38 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
220 | Geofence zone 39 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
221 | Geofence zone 40 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
222 | Geofence zone 41 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
223 | Geofence zone 42 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
224 | Geofence zone 43 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
225 | Geofence zone 44 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
226 | Geofence zone 45 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
227 | Geofence zone 46 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
228 | Geofence zone 47 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
229 | Geofence zone 48 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
230 | Geofence zone 49 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
231 | Geofence zone 50 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
175 | Auto Geofence | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
Eventual I/O elements | |
250 | Trip | 1 | Unsigned | 0 | 1 | - | - |
0 – trip stop |
Eventual I/O elements | |
255 | Over Speeding | 1 | Unsigned | 0 | 255 | - | km/h |
At over speeding start km/h, at over speeding end km/h |
Eventual I/O elements | |
257 | Crash trace data | Variable | HEX | 0 | 1200 | - | - | Crash trace data | Eventual I/O elements | |
285 | Blood alcohol content | 2 | Unsigned | 0 | 9999 | - | - | Alcohol content in blood in perlims and mode. First 14 bits from MSB are perlims multiplied by 1000 and last to bits are 0 - Passive test, 1 Active test, 2 and 3 are reserved. | FMB125 | Eventual I/O elements |
251 | Idling | 1 | Unsigned | 0 | 1 | - | - |
0 – moving |
Eventual I/O elements | |
253 | Green driving type | 1 | Unsigned | 1 | 3 | - | - |
1 – harsh acceleration |
Eventual I/O elements | |
246 | Towing | 1 | Unsigned | 0 | 1 | - | - |
0 – steady |
Eventual I/O elements | |
252 | Unplug | 1 | Unsigned | 0 | 1 | - | - |
0 – battery present |
Eventual I/O elements | |
247 | Crash detection | 1 | Unsigned | 1 | 6 | - | - |
1 – real crash detected (device is calibrated) |
Eventual I/O elements | |
248 | Immobilizer | 1 | Unsigned | 0 | 2 | - | - |
0 – iButton not connected |
Eventual I/O elements | |
254 | Green Driving Value | 1 | Unsigned | 0 | 255 | acc and braking: 0.01 | G or rad |
Depending on green driving type: if harsh acceleration or braking – g*100 (value 123 -> 1.23g). If Green driving source is „GPS“ – harsh cornering value is rad/s*100. If source is „Accelerometer“ – g*100. | Eventual I/O elements | |
249 | Jamming | 1 | Unsigned | 0 | 1 | - | - |
0 – jamming stop |
Eventual I/O elements | |
14 | ICCID2 | 8 | Unsigned | 0 | 0xFFFFFFFFFFFFFFFF | - | - |
Value of SIM ICCID, LSB |
Eventual I/O elements | |
243 | Green driving event duration | 2 | Unsigned | 0 | 65535 | - | ms |
Duration of event that did generate Green driving |
Eventual I/O elements | |
236 | Alarm | 1 | Unsigned | 0 | 1 | - | - |
0 – Reserved |
Eventual I/O elements | |
258 | EcoMaximum | 8 | Unsigned | 0 | 0xFFFFFFFFFFFFFFFF | - | - |
Element stores maximum accelerometer values in mg on all axis during Eco driving event |
Eventual I/O elements | |
259 | EcoAverage | 8 | Unsigned | 0 | 0xFFFFFFFFFFFFFFFF | - | - |
Element stores average accelerometer values in mg on all axis during Eco driving event |
Eventual I/O elements | |
260 | EcoDuration | 2 | Unsigned | 0 | 65535 | - | ms |
Duration of Eco driving event in miliseconds |
Eventual I/O elements | |
283 | Driving State | 1 | Unsigned | 0 | 3 | - | - |
1 - Ignition ON |
Eventual I/O elements | |
284 | Driving Records | 2 | Unsigned | 0 | 65535 | - | - |
Number of Records between Ignition ON and Ignition OFF |
Eventual I/O elements | |
317 | Crash event counter | 1 | Unsigned | 0 | 255 | - | - | Connects trace with specific eventual crash record | Eventual I/O elements | |
318 | GNSS Jamming | 1 | Unsigned | 0 | 2 | - | - | GNSS Jamming state:
0 - GPS jamming ended/healthy state |
Eventual I/O elements | |
391 | Private mode | 1 | Unsigned | 0 | 255 | - | - | Private mode state:
0 - Private mode off |
Eventual I/O elements | |
449 | Ignition On Counter | 4 | Unsigned | 0 | 2147483647 | - | s |
Duration in seconds which is counted while Ignition state is On |
Eventual I/O elements | |
1412 | Motorcycle Fall Detection | 1 | Unsigned | 0 | 0 | - | - |
Fall detection event which is generated when all conditions are met |
Eventual I/O elements |
OBD elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
256 | VIN | 17 | ASCII | 0 | 0xff | - | - | VIN number | OBD elements | |
30 | Number of DTC | 1 | Unsigned | 0 | 255 | - | - | Number of DTC | OBD elements | |
31 | Engine Load | 1 | Unsigned | 0 | 100 | - | % | Calculated engine load value | OBD elements | |
32 | Coolant Temperature | 1 | Signed | -128 | 127 | - | °C |
Engine coolant temperature |
OBD elements | |
33 | Short Fuel Trim | 1 | Signed | -100 | 99 | - | % |
Short term fuel trim 1 |
OBD elements | |
34 | Fuel pressure | 2 | Unsigned | 0 | 765 | - | kPa |
Fuel pressure |
OBD elements | |
35 | Intake MAP | 1 | Unsigned | 0 | 255 | - | kPa |
Intake manifold absolute pressure |
OBD elements | |
36 | Engine RPM | 2 | Unsigned | 0 | 16384 | - | rpm |
Engine RPM |
OBD elements | |
37 | Vehicle Speed | 1 | Unsigned | 0 | 255 | - | km/h |
Vehicle speed |
OBD elements | |
38 | Timing Advance | 1 | Signed | -64 | 64 | - | ° |
Timing advance |
OBD elements | |
39 | Intake Air Temperature | 1 | Signed | -128 | 127 | - | °C |
Intake air temperature |
OBD elements | |
40 | MAF | 2 | Unsigned | 0 | 65535 | 0.01 | g/sec |
MAF air flow rate |
OBD elements | |
41 | Throttle Position | 1 | Unsigned | 0 | 100 | - | % |
Throttle position |
OBD elements | |
42 | Runtime since engine start | 2 | Unsigned | 0 | 65535 | - | s |
Runtime since engine start |
OBD elements | |
43 | Distance Traveled MIL On | 2 | Unsigned | 0 | 65535 | - | km |
Distance ormattin MIL on |
OBD elements | |
44 | Relative Fuel Rail Pressure | 2 | Unsigned | 0 | 5178 | 0.1 | kPa |
Relative fuel rail pressure |
OBD elements | |
45 | Direct Fuel Rail Pressure | 2 | Unsigned | 0 | 65535 | 10 | kPa |
Direct Fuel Rail Pressure |
OBD elements | |
46 | Commanded EGR | 1 | Unsigned | 0 | 100 | - | % |
Commanded EGR |
OBD elements | |
47 | EGR Error | 1 | Signed | -100 | 100 | - | % |
EGR error |
OBD elements | |
48 | Fuel Level | 1 | Unsigned | 0 | 100 | - | % |
Fuel level |
OBD elements | |
49 | Distance Since Codes Clear | 2 | Unsigned | 0 | 65535 | - | km |
Distance traveled since codes cleared |
OBD elements | |
50 | Barometic Pressure | 1 | Unsigned | 0 | 255 | - | kPa |
Barometic pressure |
OBD elements | |
51 | Control Module Voltage | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Control module voltage |
OBD elements | |
52 | Absolute Load Value | 2 | Unsigned | 0 | 25700 | - | % |
Absolute load value |
OBD elements | |
759 | Fuel Type | 1 | Unsigned | 0 | 255 | - | - |
0 Not available |
OBD elements | |
53 | Ambient Air Temperature | 1 | Signed | -128 | 127 | - | °C |
Ambient air temperature |
OBD elements | |
54 | Time Run With MIL On | 2 | Unsigned | 0 | 65535 | - | min |
Time run with MIL on |
OBD elements | |
55 | Time Since Codes Cleared | 2 | Unsigned | 0 | 65535 | - | min |
Time since codes cleared |
OBD elements | |
56 | Absolute Fuel Rail Pressure | 2 | Unsigned | 0 | 65535 | 0.1 | kPa |
Absolute fuel rail pressure |
OBD elements | |
57 | Hybrid battery pack life | 1 | Unsigned | 0 | 100 | - | % |
Hybrid battery pack remaining life |
OBD elements | |
58 | Engine Oil Temperature | 1 | Unsigned | 0 | 215 | - | °C |
Engine oil temperature |
OBD elements | |
59 | Fuel injection timing | 2 | Signed | -21000 | 30200 | 0.01 | ° |
Fuel injection timing |
OBD elements | |
540 | Throttle position group | 1 | Unsigned | 0 | 100 | – | % | Throttle Position Value From PID Group |
FMBXXX
FMB001 |
OBD elements |
541 | Commanded Equivalence R | 1 | Unsigned | 0 | 200 | 0.01 | - | Fuel-Air Commanded Equivalence Ratio |
FMBXXX
FMB001 |
OBD elements |
542 | Intake MAP 2 bytes | 2 | Unsigned | 0 | 2048 | - | kPa | Intake Manifold Absolute Pressure |
FMBXXX
FMB001 |
OBD elements |
543 | Hybrid System Voltage | 2 | Unsigned | 0 | 1024 | - | V |
Hybrid vehicle system voltage |
OBD elements | |
544 | Hybrid System Current | 2 | Signed | -3277 | 3277 | - | A |
Hybrid vehicle system current |
OBD elements | |
281 | Fault Codes | variable | ASCII | 0 | 128 | - | - |
Fault Codes (values separated via ",") |
OBD elements | |
60 | Fuel Rate | 2 | Unsigned | 0 | 32767 | 0.01 | L/h |
Engine fuel rate, L/h*100 |
OBD elements |
OBD OEM elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
389 | OBD OEM Total Mileage | 4 | Unsigned | 0 | 0xffffffff | - | km | Total mileage received by requesting vehicle specific PID | FMB003 | OBD OEM elements |
390 | OBD OEM Fuel Level | 4 | Unsigned | 0 | 0xffffffff | 0.1 | l | Fuel level in litres received by requesting vehicle specific PID | FMB003 | OBD OEM elements |
402 | OEM Distance Until Service | 4 | Unsigned | 0 | 0xffffffff | - | km | Distance till next service received by requesting vehicle specific PID | FMB001 FMC001 FMM001 FMB003 FMC003 FMM003 | OBD OEM elements |
410 | OEM Battery charge state | 1 | Unsigned | 0 | 1 | - | - |
0 – Not charging |
FMB001 FMC001 FMM001 FMB003 FMC003 FMM003 | OBD OEM elements |
411 | OEM Battery charge level | 1 | Unsigned | 0 | 100 | - | % | Represents battery charged level | FMB001 FMC001 FMM001 FMB003 FMC003 FMM003 | OBD OEM elements |
755 | OEM Remaining distance | 2 | Unsigned | 0 | 65535 | - | km | Remaining distance until fuel tank empty or battery (EV) depleted | FMB001 FMC001 FMM001 FMB003 FMC003 FMM003 | OBD OEM elements |
1151 | OEM Battery State Of Health | 2 | Unsigned | 0 | 65535 | - | % | Battery State of Health | FMB001 FMC001 FMM001 FMB003 FMC003 FMM003 | OBD OEM elements |
1152 | OEM Battery Temperature | 2 | Signed | -32768 | 32767 | - | °C | Battery pack temperature | FMB001 FMC001 FMM001 FMB003 FMC003 FMM003 | OBD OEM elements |
BLE Sensors I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
385 | Beacon | Variable | HEX | 0 | 1024 | - | - | List of Beacon IDs | Permanent I/O elements | |
548 | Advanced BLE Beacon data | 1024 | HEX | 0 | 1024 | - | - | List of Beacon Ids and their data when advanced Beacon mode is selected | Eventual I/O elements | |
25 | BLE Temperature #1 | 2 | Signed | -4000 | 12500 | 0.01* | °C |
Degrees ( °C ), -40 - +125; |
Bluetooth Low Energy | |
26 | BLE Temperature #2 | 2 | Signed | -4000 | 12500 | 0.01* | °C |
Degrees ( °C ), -40 - +125; |
Bluetooth Low Energy | |
27 | BLE Temperature #3 | 2 | Signed | -4000 | 12500 | 0.01* | °C |
Degrees ( °C ), -40 - +125; |
Bluetooth Low Energy | |
28 | BLE Temperature #4 | 2 | Signed | -4000 | 12500 | 0.01* | °C |
Degrees ( °C ), -40 - +125; |
Bluetooth Low Energy | |
29 | BLE Battery #1 | 1 | Unsigned | 0 | 100 | - | % | Battery level of sensor #1 | Bluetooth Low Energy | |
20 | BLE Battery #2 | 1 | Unsigned | 0 | 100 | - | % | Battery level of sensor #2 | Bluetooth Low Energy | |
22 | BLE Battery #3 | 1 | Unsigned | 0 | 100 | - | % | Battery level of sensor #3 | Bluetooth Low Energy | |
23 | BLE Battery #4 | 1 | Unsigned | 0 | 100 | - | % | Battery level of sensor #4 | Bluetooth Low Energy | |
86 | BLE Humidity #1 | 2 | Unsigned | 0 | 1000 | 0.1* | %RH | Humidity From firmware version 03.28.00 and up: |
Bluetooth Low Energy | |
104 | BLE Humidity #2 | 2 | Unsigned | 0 | 1000 | 0.1* | %RH | Humidity From firmware version 03.28.00 and up: |
Bluetooth Low Energy | |
106 | BLE Humidity #3 | 2 | Unsigned | 0 | 1000 | 0.1* | %RH | Humidity From firmware version 03.28.00 and up: |
Bluetooth Low Energy | |
108 | BLE Humidity #4 | 2 | Unsigned | 0 | 1000 | 0.1* | %RH | Humidity From firmware version 03.28.00 and up: |
Bluetooth Low Energy | |
270 | BLE Fuel Level #1 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Bluetooth Low Energy | |
273 | BLE Fuel Level #2 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Bluetooth Low Energy | |
276 | BLE Fuel Level #3 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Bluetooth Low Energy | |
279 | BLE Fuel Level #4 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Bluetooth Low Energy | |
306 | BLE Fuel Frequency #1 | 4 | Unsigned | 0 | 2147483647 | - | - | Frequency value of BLE fuel sensor #1 | Bluetooth Low Energy | |
307 | BLE Fuel Frequency #2 | 4 | Unsigned | 0 | 2147483647 | - | - | Frequency value of BLE fuel sensor #2 | Bluetooth Low Energy | |
308 | BLE Fuel Frequency #3 | 4 | Unsigned | 0 | 2147483647 | - | - | Frequency value of BLE fuel sensor #3 | Bluetooth Low Energy | |
309 | BLE Fuel Frequency #4 | 4 | Unsigned | 0 | 2147483647 | - | - | Frequency value of BLE fuel sensor #4 | Bluetooth Low Energy | |
335 | BLE Luminosity #1 | 2 | Unsigned | 0 | 0xFFFF | - | lx | Luminosity value of BLE sensor | Bluetooth Low Energy | |
336 | BLE Luminosity #2 | 2 | Unsigned | 0 | 0xFFFF | - | lx | Luminosity value of BLE sensor | Bluetooth Low Energy | |
337 | BLE Luminosity #3 | 2 | Unsigned | 0 | 0xFFFF | - | lx | Luminosity value of BLE sensor | Bluetooth Low Energy | |
338 | BLE Luminosity #4 | 2 | Unsigned | 0 | 0xFFFF | - | lx | Luminosity value of BLE sensor | Bluetooth Low Energy | |
331 | BLE 1 Custom #1 | Variable | HEX | 0 | - | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
463 | BLE 1 Custom #2 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
464 | BLE 1 Custom #3 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
465 | BLE 1 Custom #4 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
466 | BLE 1 Custom #5 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
332 | BLE 2 Custom #1 | Variable | HEX | 0 | - | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
467 | BLE 2 Custom #2 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
468 | BLE 2 Custom #3 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
469 | BLE 2 Custom #4 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
470 | BLE 2 Custom #5 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
333 | BLE 3 Custom #1 | Variable | HEX | 0 | - | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
471 | BLE 3 Custom #2 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
472 | BLE 3 Custom #3 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
473 | BLE 3 Custom #4 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
474 | BLE 3 Custom #5 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
334 | BLE 4 Custom #1 | Variable | HEX | 0 | - | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
475 | BLE 4 Custom #2 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
476 | BLE 4 Custom #3 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
477 | BLE 4 Custom #4 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
478 | BLE 4 Custom #5 | 4 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy |
CAN adapters elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
81 | Vehicle Speed | 1 | Unsigned | 0 | 255 | - | km/h | Vehicle Speed | LVCAN200, ALLCAN300, CANCONTROL | |
82 | Accelerator Pedal Position | 1 | Unsigned | 0 | 102 | - | % | Value in percentages | LVCAN200, ALLCAN300, CANCONTROL | |
83 | Fuel Consumed | 4 | Unsigned | 0 | 2147483647 | 0.1 | l | Value in liters | LVCAN200, ALLCAN300, CANCONTROL | |
84 | Fuel Level | 2 | Unsigned | 0 | 65535 | 0.1 | l | Value in liters | LVCAN200, ALLCAN300, CANCONTROL | |
85 | Engine RPM | 2 | Unsigned | 0 | 16384 | - | rpm | Value in rounds per minute | LVCAN200, ALLCAN300, CANCONTROL | |
87 | Total Mileage | 4 | Unsigned | 0 | 4294967295 | - | m | Value in meters | LVCAN200, ALLCAN300, CANCONTROL | |
89 | Fuel level | 1 | Unsigned | 0 | 100 | - | % | Value in percentages | LVCAN200, ALLCAN300, CANCONTROL | |
90 | Door Status | 2 | Unsigned | 0 | 16128 | - | - |
Door status value: Min – 0, Max – 16128 |
LVCAN200, ALLCAN300, CANCONTROL | |
100 | Program Number | 4 | Unsigned | 0 | 99999 | - | - | Value: Min – 0, Max – 99999 | LVCAN200, ALLCAN300, CANCONTROL | |
101 | Module ID 8B | 8 | Unsigned | 0 | 0xFFFFFFFFFFFFFFFF | - | - | Module ID 8 Bytes | LVCAN200, ALLCAN300, CANCONTROL | |
388 | Module ID 17B | 17 | HEX | 0 | 0x7FFFFFFFFFFFFFFF | - | - | Module ID 17 Bytes | LVCAN200, ALLCAN300, CANCONTROL | |
102 | Engine Worktime | 4 | Unsigned | 0 | 1677215 | - | min | Engine work time | ALLCAN300, CANCONTROL | |
103 | Engine Worktime (counted) | 4 | Unsigned | 0 | 1677215 | - | min | Total engine work time | ALLCAN300, CANCONTROL | |
105 | Total Mileage (counted) | 4 | Unsigned | 0 | 4294967295 | - | m | Total Vehicle Mileage | LVCAN200, ALLCAN300, CANCONTROL | |
107 | Fuel Consumed (counted) | 4 | Unsigned | 0 | 2147483647 | 0.1 | l | Total Fuel Consumed | LVCAN200, ALLCAN300, CANCONTROL | |
110 | Fuel Rate | 2 | Unsigned | 0 | 32768 | 0.1 | l/h | Fuel rate | ALLCAN300 | |
111 | AdBlue Level | 1 | Unsigned | 0 | 100 | - | % | AdBlue | ALLCAN300 | |
112 | AdBlue Level | 2 | Unsigned | 0 | 65535 | 0.1 | l | AdBlue level | ALLCAN300 | |
114 | Engine Load | 1 | Unsigned | 0 | 130 | - | % | Engine Load | ALLCAN300 | |
115 | Engine Temperature | 2 | Signed | -600 | 1270 | 0.1 | °C | Engine Temperature | LVCAN200, ALLCAN300, CANCONTROL | |
118 | Axle 1 Load | 2 | Unsigned | 0 | 32768 | - | kg | Axle 1 load | ALLCAN300 | |
119 | Axle 2 Load | 2 | Unsigned | 0 | 32768 | - | kg | Axle 2 load | ALLCAN300 | |
120 | Axle 3 Load | 2 | Unsigned | 0 | 32768 | - | kg | Axle 3 load | ALLCAN300 | |
121 | Axle 4 Load | 2 | Unsigned | 0 | 32768 | - | kg | Axle 4 load | ALLCAN300 | |
122 | Axle 5 Load | 2 | Unsigned | 0 | 32768 | - | kg | Axle 5 load | ALLCAN300 | |
123 | Control State Flags | 4 | Unsigned | 0 | 4294967295 | - | - | Control state flags | ALLCAN300, CANCONTROL | |
124 | Agricultural Machinery Flags | 8 | Unsigned | 0 | 0xFFFFFFFFFFFFFFFF | - | - | Agricultural machinery flags | ALLCAN300 | |
125 | Harvesting Time | 4 | Unsigned | 0 | 16777215 | - | min | Harvesting time | ALLCAN300 | |
126 | Area of Harvest | 4 | Unsigned | 0 | 4294967295 | - | m2 | Area of harvest in square meters | ALLCAN300 | |
127 | Mowing Efficiency | 4 | Unsigned | 0 | 4294967295 | - | m2/h | Mowing efficiency | ALLCAN300 | |
128 | Grain Mown Volume | 4 | Unsigned | 0 | 4294967295 | - | kg | Mown volume | ALLCAN300 | |
129 | Grain Moisture | 2 | Unsigned | 0 | 100 | - | % | Grain moisture | ALLCAN300 | |
130 | Harvesting Drum RPM | 2 | Unsigned | 0 | 65535 | - | rpm | Harvesting drum rpm | ALLCAN300 | |
131 | Gap Under Harvesting Drum | 1 | Unsigned | 0 | 255 | - | mm | Gap under harvesting drum | ALLCAN300 | |
132 | Security State Flags | 8 | Unsigned | 0 | 0xFFFFFFFFFFFFFFFF | - | - | Security state flags | ALLCAN300, CANCONTROL | |
133 | Tachograph Total Vehicle Distance | 4 | Unsigned | 0 | 4294967295 | - | m | Tacho Total Vehicle Distance | ALLCAN300 | |
134 | Trip Distance | 4 | Unsigned | 0 | 4294967295 | - | m | Trip distance | ALLCAN300 | |
135 | Tachograph Vehicle Speed | 2 | Unsigned | 0 | 255 | - | km/h | Tacho vehicle speed | ALLCAN300 | |
136 | Tacho Driver Card Presence | 1 | Unsigned | 0 | 3 | - | - | Tacho Driver Card Presence | ALLCAN300 | |
137 | Driver 1 States | 1 | Unsigned | 0 | 255 | - | - | Driver 1 States | ALLCAN300 | |
138 | Driver 2 States | 1 | Unsigned | 0 | 255 | - | - | Driver 2 States | ALLCAN300 | |
139 | Driver 1 Continuous Driving Time | 2 | Unsigned | 0 | 65535 | - | min. | Driver 1 Continuous Driving Time, minutes | ALLCAN300 | |
140 | Driver 2 Continuous Driving Time | 2 | Unsigned | 0 | 65535 | - | min. | Driver 2 Continuous Driving Time, minutes | ALLCAN300 | |
141 | Driver 1 Cumulative Break Time | 2 | Unsigned | 0 | 65535 | - | min. | Driver 1 Cumulative Break Time, minutes | ALLCAN300 | |
142 | Driver 2 Cumulative Break Time | 2 | Unsigned | 0 | 65535 | - | min. | Driver 2 Cumulative Break Time, minutes | ALLCAN300 | |
143 | Driver 1 Selected Activity Duration | 2 | Unsigned | 0 | 65535 | - | min. | Driver 1 Duration Of Selected Activity, minutes | ALLCAN300 | |
144 | Driver 2 Selected Activity Duration | 2 | Unsigned | 0 | 65535 | - | min. | Driver 2 Duration Of Selected Activity, minutes | ALLCAN300 | |
145 | Driver 1 Cumulative Driving Time | 2 | Unsigned | 0 | 65535 | - | min. | Driver 1 Cumulative Driving Time, minutes | ALLCAN300 | |
146 | Driver 2 Cumulative Driving Time | 2 | Unsigned | 0 | 65535 | - | min. | Driver 2 Cumulative Driving Time, minutes | ALLCAN300 | |
147 | Driver 1 ID High | 8 | Unsigned | 0 | 0xFFFFFFFFFFFFFFFF | - | - | Driver 1 ID High | ALLCAN300 | |
148 | Driver 1 ID Low | 8 | Unsigned | 0 | 0xFFFFFFFFFFFFFFFF | - | - | Driver 1 ID Low | ALLCAN300 | |
149 | Driver 2 ID High | 8 | Unsigned | 0 | 0xFFFFFFFFFFFFFFFF | - | - | Driver 2 ID High | ALLCAN300 | |
150 | Driver 2 ID Low | 8 | Unsigned | 0 | 0xFFFFFFFFFFFFFFFF | - | - | Driver 2 ID Low | ALLCAN300 | |
151 | Battery Temperature | 2 | Signed | -600 | 1270 | 0.1 | °C | Battery temperature in Celsius | ALLCAN300 | |
152 | HV Battery Level | 1 | Unsigned | 0 | 100 | - | % | Battery level in percent | ALLCAN300, CANCONTROL | |
160 | DTC Faults | 1 | Unsigned | 0 | 255 | - | - | DTC faults Count | ALLCAN300, CANCONTROL | |
161 | Slope of Arm | 2 | Signed | -3276 | 3276 | - | Degrees ° | Slope Of Arm | ALLCAN300 | |
162 | Rotation of Arm | 2 | Signed | -180 | 180 | - | Degrees ° | Rotation Of Arm | ALLCAN300 | |
163 | Eject of Arm | 2 | Unsigned | 0 | 6553 | - | m | Eject of arm | ALLCAN300 | |
164 | Horizontal Distance Arm Vehicle | 2 | Unsigned | 0 | 6553 | - | m | Horizontal Distance Arm Vehicle | ALLCAN300 | |
165 | Height Arm Above Ground | 2 | Unsigned | 0 | 6553 | - | m | Height Arm Above Ground | ALLCAN300 | |
166 | Drill RPM | 2 | Unsigned | 0 | 65535 | - | rpm | Drill RPM | ALLCAN300 | |
167 | Amount Of Spread Salt Square Meter | 2 | Unsigned | 0 | 655 | - | g/m2 | Amount Of Spread Salt Square Meter | ALLCAN300 | |
168 | Battery Voltage | 2 | Unsigned | 0 | 6553 | - | V | Battery Voltage | ALLCAN300 | |
169 | Amount Of Spread Fine Grained Salt | 4 | Unsigned | 0 | 1677722 | - | T | Amount Of Spread Fine Grained Salt | ALLCAN300 | |
170 | Amount Of Coarse Grained Salt | 4 | Unsigned | 0 | 1677722 | - | T | Amount Of Coarse Grained Salt | ALLCAN300 | |
171 | Amount Of Spread DiMix | 4 | Unsigned | 0 | 1677722 | - | T | Amount Of Spread DiMix | ALLCAN300 | |
172 | Amount Of Spread Coarse Grained Calcium | 4 | Unsigned | 0 | 1677722 | - | m3 | Amount Of Spread Coarse Grained Calcium | ALLCAN300 | |
173 | Amount Of Spread Calcium Chloride | 4 | Unsigned | 0 | 1677722 | - | m3 | Amount Of Spread Calcium Chloride | ALLCAN300 | |
174 | Amount Of Spread Sodium Chloride | 4 | Unsigned | 0 | 1677722 | - | m3 | Amount Of Spread Sodium Chloride | ALLCAN300 | |
176 | Amount Of Spread Magnesium Chloride | 4 | Unsigned | 0 | 1677722 | - | m3 | Amount Of Spread Magnesium Chloride | ALLCAN300 | |
177 | Amount Of Spread Gravel | 4 | Unsigned | 0 | 1677722 | - | T | Amount Of Spread Gravel | ALLCAN300 | |
178 | Amount Of Spread Sand | 4 | Unsigned | 0 | 1677722 | - | T | Amount Of Spread Sand | ALLCAN300 | |
183 | Width Pouring Left | 2 | Unsigned | 0 | 655 | - | m | Width Pouring Left | ALLCAN300 | |
184 | Width Pouring Right | 2 | Unsigned | 0 | 655 | - | m | Width Pouring Right | ALLCAN300 | |
185 | Salt Spreader Working Hours | 4 | Unsigned | 0 | 167722 | - | h | Salt Spreader Working Hours | ALLCAN300 | |
186 | Distance During Salting | 4 | Unsigned | 0 | 167722 | - | km | Distance During Salting | ALLCAN300 | |
187 | Load Weight | 4 | Unsigned | 0 | 16772215 | - | kg | Load Weight | ALLCAN300 | |
188 | Retarder Load | 1 | Unsigned | 0 | 130 | - | % | Retarded Load in percent | ALLCAN300 | |
189 | Cruise Time | 4 | Unsigned | 0 | 16772215 | - | min | Cruise time in minutes | ALLCAN300 | |
232 | CNG Status | 1 | Unsigned | 0 | 1 | - | - | CNG Status | LVCAN200, CANCONTROL | |
233 | CNG Used | 4 | Unsigned | 0 | 16772215 | - | kg | CNG used | LVCAN200, CANCONTROL | |
234 | CNG Level | 1 | Unsigned | 0 | 100 | - | % | CNG Level | LVCAN200, CANCONTROL | |
235 | Oil Level | 1 | Unsigned | 0 | 1 | - | - | Engine Oil Level Indicator Status | ALLCAN300, CANCONTROL | |
304 | Vehicles Range On Battery | 4 | Unsigned | 0 | 16777215 | - | m | Vehicle Range on Battery | ALLCAN300, CANCONTROL | |
305 | Vehicles Range On Additional Fuel | 4 | Unsigned | 0 | 16777215 | - | m | Vehicle Range On Additional Fuel | ALLCAN300, CANCONTROL | |
325 | VIN | 17 | ASCII | 0 | 0xFF | - | - | VIN number | ALLCAN300, CANCONTROL | |
282 | Fault Codes | Variable | - | 0 | 128 | - | - | DTC Fault codes | LV-CAN200 + DTC | |
517 | Security State Flags P4 | 8 | HEX | 0 | 0xffffffffffffffff | - | - | Security state flags protocol 4, more information click here Flags |
FMBXXX
FMB140 |
ALLCAN300 |
518 | Control State Flags P4 | 8 | HEX | 0 | 0xffffffffffffffff | - | - | Control state flags protocol 4, more information click here Flags |
FMBXXX
FMB140 |
ALLCAN300 |
519 | Indicator State Flags P4 | 8 | HEX | 0 | 0xffffffffffffffff | - | - | Indicator state flags protocol 4, more information click here Flags |
FMBXXX
FMB140 |
ALLCAN300 |
520 | Agricultural State Flags P4 | 8 | HEX | 0 | 0xffffffffffffffff | - | - | Agricultural state flags protocol 4, more information click here Flags |
FMBXXX
FMB140 |
ALLCAN300 |
521 | Utility State Flags P4 | 8 | HEX | 0 | 0xffffffffffffffff | - | - | Utility state flags protocol 4, more information click here Flags |
FMBXXX
FMB140 |
ALLCAN300 |
522 | Cistern State Flags P4 | 8 | HEX | 0 | 0xffffffffffffffff | - | - | Cistern state flags protocol 4, more information click here Flags |
FMBXXX
FMB140 |
ALLCAN300 |
855 | LNG Used | 4 | Unsigned | 0 | 214748364 | - | kg | Total LNG used in kilograms |
FMBXXX
FMB140 |
ALLCAN300, CANCONTROL |
856 | LNG Used (counted) | 4 | Unsigned | 0 | 214748364 | - | kg | Total LNG used counted in kg |
FMBXXX
FMB140 |
ALLCAN300, CANCONTROL |
857 | LNG Level | 2 | Unsigned | 0 | 100 | - | % | LNG level in proc |
FMBXXX
FMB140 |
ALLCAN300, CANCONTROL |
858 | LNG Level | 2 | Unsigned | 0 | 6553 | - | kg | LNG level in kg |
FMBXXX
FMB140 |
ALLCAN300, CANCONTROL |
1100 | Total LPG Used | 4 | Unsigned | 0 | 4294967295 | - | l | Total LPG used in liters |
FMBXXX
FMB140 |
LVCAN |
1101 | Total LPG Used Counted | 4 | Unsigned | 0 | 4294967295 | - | l | Total LPG used counted in liters |
FMBXXX
FMB140 |
LVCAN |
1102 | LPG Level Proc | 2 | Unsigned | 0 | 65535 | - | % | LPG level in proc |
FMBXXX
FMB140 |
LVCAN |
1103 | LPG Level Liters | 2 | Unsigned | 0 | 65535 | - | l | LPG level in liters |
FMBXXX
FMB140 |
LVCAN |
898 | SSF Ignition | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
LVCAN, ALLCAN300, CANCONTROL | |
652 | SSF KeyInIgnitionLock | 1 | Unsigned | 0 | 1 | - | - |
0 - No key in lock |
ALLCAN300, CANCONTROL | |
899 | SSF Webasto | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
900 | SSF Engine Working | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300, CANCONTROL | |
901 | SSF Standalone Engine | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
902 | SSF Ready To Drive | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300, CANCONTROL | |
903 | SSF Engine Working On CNG | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300, CANCONTROL | |
904 | SSF Work Mode | 1 | Unsigned | 0 | 1 | - | - |
0 - Private |
ALLCAN300 | |
905 | SSF Operator | 1 | Unsigned | 0 | 1 | - | - |
0 - Not present |
ALLCAN300 | |
906 | SSF Interlock | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
907 | SSF Engine Lock Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
CANCONTROL | |
908 | SSF Request To Lock Engine | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
CANCONTROL | |
653 | SSF Handbrake Is Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Handbrake inactive |
ALLCAN300, CANCONTROL | |
910 | SSF Footbrake Is Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Footbrake inactive |
ALLCAN300, CANCONTROL | |
911 | SSF Clutch Pushed | 1 | Unsigned | 0 | 1 | - | - |
0 - Clutch is pushed |
ALLCAN300, CANCONTROL | |
912 | SSF Hazard Warning Lights | 1 | Unsigned | 0 | 1 | - | - |
0 - Hazard warning lights on |
ALLCAN300, CANCONTROL | |
654 | SSF Front Left Door Open | 1 | Unsigned | 0 | 1 | - | - |
0 - Closed |
LVCAN, ALLCAN300, CANCONTROL | |
655 | SSF Front Right Door Open | 1 | Unsigned | 0 | 1 | - | - |
0 - Closed |
LVCAN, ALLCAN300, CANCONTROL | |
656 | SSF Rear Left Door Open | 1 | Unsigned | 0 | 1 | - | - |
0 - Closed |
LVCAN, ALLCAN300, CANCONTROL | |
657 | SSF Rear Right Door Open | 1 | Unsigned | 0 | 1 | - | - |
0 - Closed |
LVCAN, ALLCAN300, CANCONTROL | |
658 | SSF Trunk Door Open | 1 | Unsigned | 0 | 1 | - | - |
0 - Closed |
LVCAN, ALLCAN300, CANCONTROL | |
913 | SSF Engine Cover Open | 1 | Unsigned | 0 | 1 | - | - |
0 - Closed |
LVCAN, ALLCAN300, CANCONTROL | |
909 | SSF Roof Open | 1 | Unsigned | 0 | 1 | - | - |
0 - Closed |
LVCAN, ALLCAN300, CANCONTROL | |
914 | SSF Charging Wire Plugged | 1 | Unsigned | 0 | 1 | - | - |
0 - Unplugged |
ALLCAN300, CANCONTROL | |
915 | SSF Batttery Charging | 1 | Unsigned | 0 | 1 | - | - |
0 - Not charging |
ALLCAN300, CANCONTROL | |
916 | SSF Electric Engine State | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300, CANCONTROL | |
917 | SSF Car Closed Factory Remote | 1 | Unsigned | 0 | 1 | - | - |
0 - Closed |
ALLCAN300, CANCONTROL | |
662 | SSF Car Is Closed | 1 | Unsigned | 0 | 1 | - | - |
0 - Closed |
ALLCAN300, CANCONTROL | |
918 | SSF Factory Alarm Actuated | 1 | Unsigned | 0 | 1 | - | - |
0 - Not actuated |
ALLCAN300, CANCONTROL | |
919 | SSF Factory Alarm Emulated | 1 | Unsigned | 0 | 1 | - | - |
0 - Not emulated |
ALLCAN300, CANCONTROL | |
920 | SSF Signal Close Factory Remote | 1 | Unsigned | 0 | 1 | - | - |
0 - Closed |
ALLCAN300, CANCONTROL | |
921 | SSF Signal Open Factory Remote | 1 | Unsigned | 0 | 1 | - | - |
0 - Closed |
ALLCAN300, CANCONTROL | |
922 | SSF Rearming Signal | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300, CANCONTROL | |
923 | SSF Trunk Door Opened Factory Remote | 1 | Unsigned | 0 | 1 | - | - |
0 - Closed |
ALLCAN300, CANCONTROL | |
924 | SSF CAN Module In Sleep | 1 | Unsigned | 0 | 1 | - | - |
0 - Not in sleep |
LVCAN, ALLCAN300, CANCONTROL | |
925 | SSF Factory Remote 3x | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
926 | SSF Factory Armed | 1 | Unsigned | 0 | 1 | - | - |
0 - Not armed |
CANCONTROL | |
660 | SSF Parking Gear Active (automatic gear box) | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300, CANCONTROL | |
661 | SSF Reverse Gear Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300, CANCONTROL | |
659 | SSF Neutral Gear Active (automatic gear box) | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300, CANCONTROL | |
927 | SSF Drive Is Active (automatic gear box) | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300, CANCONTROL | |
1083 | SSF Engine Working On Dual Fuel | 1 | Unsigned | 0 | 1 | - | - |
0 - Not working |
ALLCAN300 | |
1084 | SSF Engine Working On LPG | 1 | Unsigned | 0 | 1 | - | - |
0 - Not working |
ALLCAN300 | |
928 | CSF Parking Lights | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300, CANCONTROL | |
929 | CSF Dipped Head lights | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300, CANCONTROL | |
930 | CSF Full Beam Headlights | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300, CANCONTROL | |
931 | CSF Rear Fog Lights | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300, CANCONTROL | |
932 | CSF Front Fog Lights | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300, CANCONTROL | |
933 | CSF Additional Front Lights | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
934 | CSF Additional Rear Lights | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
935 | CSF Light Signal | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
936 | CSF Air Conditioning | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
937 | CSF Cruise Control | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
938 | CSF Automatic Retarder | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
939 | CSF Manual Retarder | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
940 | CSF Driver's Seatbelt Fastened | 1 | Unsigned | 0 | 1 | - | - |
0 - Not fastened |
ALLCAN300 | |
941 | CSF Front Driver's Seatbelt Fastened | 1 | Unsigned | 0 | 1 | - | - |
0 - Not fastened |
ALLCAN300 | |
942 | CSF Left Driver's Seatbelt Fastened | 1 | Unsigned | 0 | 1 | - | - |
0 - Not fastened |
ALLCAN300 | |
943 | CSF Right Driver's Seatbelt Fastened | 1 | Unsigned | 0 | 1 | - | - |
0 - Not fastened |
ALLCAN300 | |
944 | CSF Centre Driver's Seatbelt Fastened | 1 | Unsigned | 0 | 1 | - | - |
0 - Not fastened |
ALLCAN300 | |
945 | CSF Front Passenger Present | 1 | Unsigned | 0 | 1 | - | - |
0 - Not present |
ALLCAN300 | |
946 | CSF PTO | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
947 | CSF Front Differential Locked | 1 | Unsigned | 0 | 1 | - | - |
0 - Unlocked |
ALLCAN300 | |
948 | CSF Rear Differential Locked | 1 | Unsigned | 0 | 1 | - | - |
0 - Unlocked |
ALLCAN300 | |
949 | CSF Central Differential 4HI Locked | 1 | Unsigned | 0 | 1 | - | - |
0 - Unlocked |
ALLCAN300 | |
950 | CSF Rear Differential 4LO Locked | 1 | Unsigned | 0 | 1 | - | - |
0 - Unlocked |
ALLCAN300 | |
951 | CSF Trailer Axle 1 Lift Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300 | |
952 | CSF Trailer Axle 2 Lift Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300 | |
1085 | CSF Trailer Connected | 1 | Unsigned | 0 | 1 | - | - |
0 - Disconnected |
ALLCAN300 | |
1086 | CSF Start Stop System Inactive | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
953 | ISF Check Engine Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
954 | ISF ABS Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
955 | ISF ESP Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
956 | ISF ESP Turned Off | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
957 | ISF Stop Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
958 | ISF Oil Level Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300, CANCONTROL | |
959 | ISF Coolant liquid level | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
960 | ISF Battery Not Charging Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
961 | ISF Handbrake System Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
962 | ISF AIRBAG Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
963 | ISF EPS Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
964 | ISF Warning Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
965 | ISF Lights Failure Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
966 | ISF Low Tire Pressure Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
967 | ISF Wear Of Brake Pads Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
968 | ISF Low Fuel Level Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
969 | ISF Maintenence required Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
970 | ISF Glow Plug Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
971 | ISF FAP Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
972 | ISF EPC (Electronic Power Control) Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
973 | ISF Clogged Engine Oil Filter Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
974 | ISF Low Engine Oil Pressure Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
975 | ISF Too High Engine Oil Temperature Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
976 | ISF Low Coolant Level Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
977 | ISF Clogged Hydraulic System Oil filter Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
978 | ISF Hydraulic System Low Pressure Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
979 | ISF Hydraulic Oil Low Level Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
980 | ISF Hydraulic System High Temperature Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
981 | ISF Oil Overflow In Hydraulic Chamber Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
982 | ISF Clogged Air Filter Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
983 | ISF Clogged Fuel Filter Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
984 | ISF Water in Fuel Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
985 | ISF Clogged Brake System Filter Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
986 | ISF Low Washer Fluid Level Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
LVCAN, ALLCAN300 | |
987 | ISF Low AdBlue Level Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
LVCAN, ALLCAN300 | |
988 | ISF Low Trailer Tyre Pressure Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
989 | ISF Wear Of Trailer Brake Lining Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
990 | ISF High Trailer Brake Temperature Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
991 | ISF Incorrect Trailer Pneumatic Supply Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
992 | ISF Low CNG Level Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
LVCAN, ALLCAN300 | |
993 | ASF Right Joystick Moved Right Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300 | |
994 | ASF Right Joystick Moved Left Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300 | |
995 | ASF Right Joystick Moved Forward Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300 | |
996 | ASF Right Joystick Moved Back Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300 | |
997 | ASF Left Joystick Moved Right Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300 | |
998 | ASF Left Joystick Moved Left Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300 | |
999 | ASF Left Joystick Moved Forward Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300 | |
1000 | ASF Left Joystick Moved Back Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300 | |
1001 | ASF First Rear hydraulic | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1002 | ASF Second Rear hydraulic | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1003 | ASF Third Rear hydraulic | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1004 | ASF Fourth Rear hydraulic | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1005 | ASF First Front hydraulic | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1006 | ASF Second Front hydraulic | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1007 | ASF Third Front hydraulic | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1008 | ASF Fourth Front hydraulic | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1009 | ASF Front Three-point Hitch | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1010 | ASF Rear Three-point Hitch | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1011 | ASF Front Power Take-off | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1012 | ASF Rear Power Take-off | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1013 | ASF Mowing Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300 | |
1014 | ASF Threshing Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Inactive |
ALLCAN300 | |
1015 | ASF Grain Release From Hopper | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1016 | ASF Grain Tank Is 100% Full | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1017 | ASF Grain Tank Is 70% Full | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1018 | ASF Grain Tank Is Opened | 1 | Unsigned | 0 | 1 | - | - |
0 - Closed |
ALLCAN300 | |
1019 | ASF Unloader Drive | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1020 | ASF Cleaning Fan Control Turned Off | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1021 | ASF Threshing Drum Control Turned Off | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1022 | ASF Straw Walker Is Clogged | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1023 | ASF Excessive Clearance Under The Threshing Drum | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1024 | ASF Low Temperature Of Drive System Hydraulics Less Than 5 Grades | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1025 | ASF High Temperature Of Drive System Hydraulics Greater Than 86 Grades | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1026 | ASF Ear Auger Speed Below The Norm | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1027 | ASF Grain Auger Speed Below The Norm | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1028 | ASF Straw Chooper Speed Below The Norm | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1029 | ASF Straw Shaker Speed Below The Norm | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1030 | ASF Feeder Speed Below The Norm | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1031 | ASF Straw Chopper Switched On | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1032 | ASF Corn Header Connected | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1033 | ASF Grain Header Connected | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1034 | ASF Feeder Reverse Switched On | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1035 | ASF The Pressure Filter Of The Hydraulic Pump Is Clogged | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1087 | ASF Adapter Pressure Filter Sensor | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1088 | ASF Service 2 Required Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1089 | ASF Drain Filter Clogged Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1090 | ASF Section 1 Spraying | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1091 | ASF Section 2 Spraying | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1092 | ASF Section 3 Spraying | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1093 | ASF Section 4 Spraying | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1094 | ASF Section 5 Spraying | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1095 | ASF Section 6 Spraying | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1096 | ASF Section 7 Spraying | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1097 | ASF Section 8 Spraying | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1098 | ASF Section 9 Spraying | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1036 | USF Spreading | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1037 | USF Pouring Chemicals | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1038 | USF Conveyor Belt | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1039 | USF Salt Spreader's Drive Wheel | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1040 | USF Brushes | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1041 | USF Vacuum Cleaner | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1042 | USF Water Supply | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1043 | USF Spreading | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1044 | USF Liquid pump | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1045 | USF Unloading From The Hopper | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1046 | USF Low Salt (Sand) Level In Container Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1047 | USF Low Water Level in Container Indicator | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1048 | USF Chemicals | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1049 | USF Compressor | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1050 | USF Water Valve Is Opened | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1051 | USF Cabin Moved Up Status Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1052 | USF Cabin Moved Down Status Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1099 | USF Hydraulics Work Not Permitted | 1 | Unsigned | 0 | 1 | - | - |
0 - Off |
ALLCAN300 | |
1053 | CiSF Section 1 Presence Of Fluid In The Downpipe | 1 | Unsigned | 0 | 1 | - | - |
0 - No presence |
ALLCAN300 | |
1054 | CiSF Section 1 Filled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1055 | CiSF Section 1 Overfilled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1056 | CiSF Section 2 Presence Of Fluid In The Downpipe | 1 | Unsigned | 0 | 1 | - | - |
0 - No presence |
ALLCAN300 | |
1057 | CiSF Section 2 Filled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1058 | CiSF Section 2 Overfilled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1059 | CiSF Section 3 Presence Of Fluid In The Downpipe | 1 | Unsigned | 0 | 1 | - | - |
0 - No presence |
ALLCAN300 | |
1060 | CiSF Section 3 Filled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1061 | CiSF Section 3 Overfilled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1062 | CiSF Section 4 Presence Of Fluid In The Downpipe | 1 | Unsigned | 0 | 1 | - | - |
0 - No presence |
ALLCAN300 | |
1063 | CiSF Section 4 Filled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1064 | CiSF Section 4 Overfilled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1065 | CiSF Section 5 Presence Of Fluid In The Downpipe | 1 | Unsigned | 0 | 1 | - | - |
0 - No presence |
ALLCAN300 | |
1066 | CiSF Section 5 Filled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1067 | CiSF Section 5 Overfilled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1068 | CiSF Section 6 Presence Of Fluid In The Downpipe | 1 | Unsigned | 0 | 1 | - | - |
0 - No presence |
ALLCAN300 | |
1069 | CiSF Section 6 Filled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1070 | CiSF Section 6 Overfilled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1071 | CiSF Section 7 Presence Of Fluid In The Downpipe | 1 | Unsigned | 0 | 1 | - | - |
0 - No presence |
ALLCAN300 | |
1072 | CiSF Section 7 Filled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1073 | CiSF Section 7 Overfilled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1074 | CiSF Section 8 Presence Of Fluid In The Downpipe | 1 | Unsigned | 0 | 1 | - | - |
0 - No presence |
ALLCAN300 | |
1075 | CiSF Section 8 Filled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
1076 | CiSF Section 8 Overfilled | 1 | Unsigned | 0 | 1 | - | - |
0 - No |
ALLCAN300 | |
400 | Distance to Next Service | 4 | Unsigned | 0 | 4294967295 | - | - | CAN adapters | ||
450 | CNG Level Kg | 2 | Unsigned | 0 | 65535 | 10 | Kg | CNG Level Kg (appears only if CNG level percentage is not available) | CAN adapters | |
859 | Distance from need of service | 4 | Unsigned | 0 | 4294967295 | - | km | Service - distance elapsed since the occurrence of the need for servicing | CAN adapters | |
860 | Distance from last service | 4 | Unsigned | 0 | 4294967295 | - | km | Service - distance from the last service | CAN adapters | |
861 | Time to next service | 2 | Unsigned | 0 | 65535 | - | day | Service - time to next service | CAN adapters | |
862 | Time from need of service | 2 | Unsigned | 0 | 65535 | - | day | Service - time exceeded since the occurrence of the need for servicing | CAN adapters | |
863 | Time from last serivce | 2 | Unsigned | 0 | 65535 | - | day | Service - time elapsed since the last service | CAN adapters | |
864 | Distance to next oil service | 4 | Unsigned | 0 | 4294967295 | - | km | Service - distance to next oil service | CAN adapters | |
865 | Time to next oil service | 2 | Unsigned | 0 | 65535 | - | day | Service - time to next oil service | CAN adapters | |
866 | LVCAN Vehicle Range | 4 | Unsigned | 0 | 4294967295 | - | km | Information about vehicle range | CAN adapters | |
867 | LVCAN Total CNG counted | 4 | Unsigned | 0 | 65535 | - | kg | Information about Total CNG used in counted mode | CAN adapters | |
1079 | Total Bale Count | 4 | Unsigned | 0 | 0xFFFFFFFF | - | - | Total Bale Count | CAN adapters | |
1080 | Bale Count | 4 | Unsigned | 0 | 0xFFFFFFFF | - | - | Bale Count | CAN adapters | |
1081 | Cut Bale Count | 4 | Unsigned | 0 | 0xFFFFFFFF | - | - | Cut Bale Count | CAN adapters | |
1082 | Bale Slices | 4 | Unsigned | 0 | 0xFFFFFFFF | - | - | Bale Slices | CAN adapters | |
1116 | LVCAN MaxRoadSpeed | 1 | Unsigned | 0 | 255 | - | km/h | Maximum speed from road signs | CAN adapters | |
1117 | LVCAN ExceededRoadSpeed | 1 | Unsigned | 0 | 255 | - | km/h | Exceeded speed from road signs | CAN adapters | |
1205 | LVCAN RSF SpeedLimitSign | 1 | Unsigned | 0 | 1 | - | - | Information if road sign "Speed limit with value" is recognized/canceled | CAN adapters | |
1206 | LVCAN RSF EndOfSpeedLimitSign | 1 | Unsigned | 0 | 1 | - | - | Information if road sign "End of speed limit with value" is recognized/canceled | CAN adapters | |
1207 | LVCAN RSF SpeedExceeded | 1 | Unsigned | 0 | 1 | - | - | Information if speed is exceeded indicated by road sign "Speed limit with value" | CAN adapters | |
1208 | LVCAN RSF TimeSpeedLimitSign | 1 | Unsigned | 0 | 1 | - | - | Information if road sign "Conditional time-specific speed limit with value" is recognized/canceled | CAN adapters | |
1209 | LVCAN RSF WthrSpeedLimitSign | 1 | Unsigned | 0 | 1 | - | - | Information if road sign "Speed limit with value due to weather conditions" is recognized/cancelled | CAN adapters |