==SMS commands==
 
Essential fields in ''SMS/Call settings'' are ''Login'' and ''Password''. The login and password are used with every SMS sent to {{{model|FMB640}}}. If login and password are not set, in every SMS sent to {{{model|FMB640}}} device two spaces before command have to be used '''"<space><space><command>"'''.<br/>Command structure with set login and password:<br/>
 
Essential fields in ''SMS/Call settings'' are ''Login'' and ''Password''. The login and password are used with every SMS sent to {{{model|FMB640}}}. If login and password are not set, in every SMS sent to {{{model|FMB640}}} device two spaces before command have to be used '''"<space><space><command>"'''.<br/>Command structure with set login and password:<br/>
 
'''"<login><space><password><space><command>"''', for example: "asd 123 getgps"<br/>
 
'''"<login><space><password><space><command>"''', for example: "asd 123 getgps"<br/>
Line 4: Line 6:
 
{{{pic_call_settings|[[Image:FMB640_smscall_settings.png|800px|centre]]}}}
 
{{{pic_call_settings|[[Image:FMB640_smscall_settings.png|800px|centre]]}}}
  
 +
==Incoming Call settings==
 +
{{{pic_incoming|[[Image:FMB640 Incoming Call Settings.png|300px|right]]}}}
 
''Incoming call settings'' parameter defines device action during incoming call:
 
''Incoming call settings'' parameter defines device action during incoming call:
* <span style=color:#F6A83E>Do Nothing</span>.
+
* <span style=color:#F6A83E>Do Nothing (BT HP)</span>.
* <span style=color:#F6A83E>Hang-up</span> – automatically hang up an incoming call.
+
* <span style=color:#F6A83E>Hangup</span> – automatically hang up an incoming call.
* <span style=color:#F6A83E>Report Position</span> – Report position to calling number via SMS.
+
* <span style=color:#F6A83E>Report Position</span> – report position to calling number via SMS.
* <span style=color:#F6A83E>Auto Answer (HF)</span> – Auto answer an incoming call if hands-free device is connected. If hands-free device is not connected, then an incoming call will be hung up.
+
* <span style=color:#F6A83E>Auto Answer (HF)</span> – auto answer an incoming call if hands-free device is connected. If hands-free device is not connected, then an incoming call will be hung up.
* <span style=color:#F6A83E>Auto Answer (Spy Call)</span> – Transmit sound to calling number. Caller number must be in authorized numbers list.
+
* <span style=color:#F6A83E>Spy Call</span> – transmit sound to calling number. Caller number must be in authorized numbers list.
  
When {{{model|FMB640}}} is connected to a hands-free headset, it can call to user defined GSM numbers.
+
==Hands Free Call settings==
 
+
{{{pic_handsfree|[[Image:FMB640 Hands Free Call Settings.png|250px|right]]}}}
{{{pic_handsfree|[[Image:FMB640_handsfree.png|300px|right]]}}}
+
When {{{model|FMB640}}} is connected to a hands-free headset, it can call to user-defined GSM numbers.
  
 
''Hands Free Call Settings'' parameter determines which event will trigger a call. {{{model|FMB640}}} supports four call trigger settings for each Digital Input it has:
 
''Hands Free Call Settings'' parameter determines which event will trigger a call. {{{model|FMB640}}} supports four call trigger settings for each Digital Input it has:
Line 21: Line 25:
 
* <span style=color:#F6A83E>DIN3</span> –  digital input 3 event triggers a call to user selected GSM number.
 
* <span style=color:#F6A83E>DIN3</span> –  digital input 3 event triggers a call to user selected GSM number.
 
* <span style=color:#F6A83E>DIN4</span> –  digital input 4 event triggers a call to user selected GSM number.
 
* <span style=color:#F6A83E>DIN4</span> –  digital input 4 event triggers a call to user selected GSM number.
 +
 +
 +
 +
 +
 +
 +
 +
 +
 +
 +
 +
  
 
{| class="wikitable" style="border-style: solid; border-width: 0px"
 
{| class="wikitable" style="border-style: solid; border-width: 0px"
Line 29: Line 45:
 
|-
 
|-
 
| style="text-align: left; background: #F6F6FB;"        | [[Image:Bw_nb.png|50px]]
 
| style="text-align: left; background: #F6F6FB;"        | [[Image:Bw_nb.png|50px]]
| style="text-align: left; background: #F6F6FB;"        | SMS login and password and authorized numbers list are used to protect {{{model|FMB640}}} module from unauthorized access. Module accepts messages only from a list of authorized numbers and with proper module login and password. Phone numbers have to be written in international standard using "+" or without using it (in both cases the number will be recognized). If no authorized numbers are entered, module accepts messages from all numbers.
+
| style="text-align: left; background: #F6F6FB;"        | SMS login and password and authorized numbers list are used to protect {{{model|FMB640}}} module from unauthorized access. Module accepts messages only from a list of authorized numbers and with proper module login and password. Phone numbers have to be written in international standard using "+" or without using it (in both cases the number will be recognized). If no authorized numbers are entered, the module accepts messages from all numbers.
 
|}
 
|}

Revision as of 09:35, 31 August 2020

SMS commands

Essential fields in SMS/Call settings are Login and Password. The login and password are used with every SMS sent to FMB640. If login and password are not set, in every SMS sent to FMB640 device two spaces before command have to be used "<space><space><command>".
Command structure with set login and password:
"<login><space><password><space><command>", for example: "asd 123 getgps"
Phone numbers have to be written in international standard, using "+" is optional but not necessary (in both cases number will be recognized, but when number is without "+" symbol, IDD Prefix will not be generated, which depends on location of the phone). If no numbers are entered, configuration and sending commands over SMS are allowed from all GSM numbers.
SMS data sending settings allow sending AVL data using binary SMS. AVL data will be sent by SMS only when there is no GPRS connection. This setting does not affect replies to SMS request messages – answers are always sent back to the sender's telephone number.

FMB640 smscall settings.png

Incoming Call settings

FMB640 Incoming Call Settings.png

Incoming call settings parameter defines device action during incoming call:

  • Do Nothing (BT HP).
  • Hangup – automatically hang up an incoming call.
  • Report Position – report position to calling number via SMS.
  • Auto Answer (HF) – auto answer an incoming call if hands-free device is connected. If hands-free device is not connected, then an incoming call will be hung up.
  • Spy Call – transmit sound to calling number. Caller number must be in authorized numbers list.

Hands Free Call settings

FMB640 Hands Free Call Settings.png

When FMB640 is connected to a hands-free headset, it can call to user-defined GSM numbers.

Hands Free Call Settings parameter determines which event will trigger a call. FMB640 supports four call trigger settings for each Digital Input it has:

  • DIN1 – digital input 1 event triggers a call to user selected GSM number.
  • DIN2 – digital input 2 event triggers a call to user selected GSM number.
  • DIN3 – digital input 3 event triggers a call to user selected GSM number.
  • DIN4 – digital input 4 event triggers a call to user selected GSM number.







Bw nb.png Please do not set Data Send Number to some cell phone number, because it will not understand binary SMS. When sending a binary SMS to a phone number, which is a server phone number, the server can interpret and understand binary code, so the data can be read and you can view it on the server.
Bw nb.png SMS login and password and authorized numbers list are used to protect FMB640 module from unauthorized access. Module accepts messages only from a list of authorized numbers and with proper module login and password. Phone numbers have to be written in international standard using "+" or without using it (in both cases the number will be recognized). If no authorized numbers are entered, the module accepts messages from all numbers.