Difference between revisions of "FMB910 Basic Teltonika Data Sending Parameters ID"
Line 1,588: | Line 1,588: | ||
</div> | </div> | ||
| style="vertical-align: middle; text-align: center; " |Eventual I/O elements | | style="vertical-align: middle; text-align: center; " |Eventual I/O elements | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|} | |} | ||
<br /> | <br /> | ||
<br /> | <br /> | ||
<br /> | <br /> |
Revision as of 16:29, 17 November 2020
FMB910 Basic > FMB910 Basic Teltonika Data Sending Parameters IDFMB AVL ID's consist of these parameters groups:
To search for compatible products, Expand all content
Permanent I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
239 | Ignition | 1 | Unsigned | 0 | 1 | - | - |
0 – Ignition Off |
Permanent I/O elements | |
240 | Movement | 1 | Unsigned | 0 | 1 | - | - |
0 – Movement Off |
Permanent I/O elements | |
80 | Data Mode | 1 | Unsigned | 0 | 5 | - | - |
0 – Home On Stop |
Permanent I/O elements | |
21 | GSM Signal | 1 | Unsigned | 0 | 5 | - | - |
Value in range 1-5 |
Permanent I/O elements | |
200 | Sleep Mode | 1 | Unsigned | 0 | 4 | - | - |
0 - No Sleep |
Permanent I/O elements | |
69 | GNSS Status | 1 | Unsigned | 0 | 3 | - | - |
0 - GNSS OFF |
Permanent I/O elements | |
181 | GNSS PDOP | 2 | Unsigned | 0 | 500 | 0.1 | m | Meters, calculation formula | Permanent I/O elements | |
182 | GNSS HDOP | 2 | Unsigned | 0 | 500 | 0.1 | m | Meters, calculation formula | Permanent I/O elements | |
66 | External Voltage | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Voltage |
Permanent I/O elements | |
24 | Speed | 2 | Unsigned | 0 | 350 | - | km/h |
Value |
Permanent I/O elements | |
205 | GSM Cell ID | 2 | Unsigned | 0 | 65535 | - | - |
GSM base station ID |
Permanent I/O elements | |
206 | GSM Area Code | 2 | Unsigned | 0 | 65535 | - | - |
Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations. |
Permanent I/O elements | |
67 | Battery Voltage | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Voltage |
Permanent I/O elements | |
68 | Battery Current | 2 | Unsigned | 0 | 65535 | 0.001 | A |
Current |
Permanent I/O elements | |
241 | Active GSM Operator | 4 | Unsigned | 0 | 4294967295 | - | - |
Currently used GSM Operator code |
Permanent I/O elements | |
199 | Trip Odometer | 4 | Unsigned | 0 | 2147483647 | - | m |
Trip Odometer value |
Permanent I/O elements | |
16 | Total Odometer | 4 | Unsigned | 0 | 2147483647 | - | - |
Total Odometer value in meters |
Permanent I/O elements | |
1 | Digital Input 1 | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
9 | Analog Input 1 | 2 | Unsigned | 0 | 65535 | 0.001 | mV |
Voltage |
Permanent I/O elements | |
179 | Digital Output 1 | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
12 | Fuel Used GPS | 4 | Unsigned | 0 | 4294967295 | 0.001 | l |
Fuel Used |
Permanent I/O elements | |
13 | Fuel Rate GPS | 2 | Unsigned | 0 | 32767 | 0.01 | l/100km |
Average Fuel Use |
Permanent I/O elements | |
17 | Axis X | 2 | Signed | -8000 | 8000 | - | mG |
X axis value |
Permanent I/O elements | |
18 | Axis Y | 2 | Signed | -8000 | 8000 | - | mG |
Y axis value |
Permanent I/O elements | |
19 | Axis Z | 2 | Signed | -8000 | 8000 | - | mG |
Z axis value |
Permanent I/O elements | |
11 | ICCID1 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - |
Value of SIM ICCID, MSB |
Permanent I/O elements | |
10 | SD Status | 1 | Unsigned | 0 | 1 | - | - |
0 - not present 1 - present |
Permanent I/O elements | |
2 | Digital Input 2 | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
3 | Digital Input 3 | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
6 | Analog Input 2 | 2 | Unsigned | 0 | 65535 | 0.001 | mV |
Voltage |
Permanent I/O elements | |
180 | Digital Output 2 | 1 | Unsigned | 0 | 1 | - | - | Logic 0/1 | Permanent I/O elements | |
72 | Dallas Temperature 1 | 4 | Signed | -550 | 1150 | 0.1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
Permanent I/O elements | |
73 | Dallas Temperature 2 | 4 | Signed | -550 | 1150 | 0.1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
Permanent I/O elements | |
74 | Dallas Temperature 3 | 4 | Signed | -550 | 1150 | 0.1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
Permanent I/O elements | |
75 | Dallas Temperature 4 | 4 | Signed | -550 | 1150 | 0.1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
Permanent I/O elements | |
76 | Dallas Temperature ID 1 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | Permanent I/O elements | |
77 | Dallas Temperature ID 2 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | Permanent I/O elements | |
79 | Dallas Temperature ID 3 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | Permanent I/O elements | |
71 | Dallas Temperature ID 4 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | Permanent I/O elements | |
78 | iButton | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | iButton ID | Permanent I/O elements | |
207 | RFID | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | RFID ID | Permanent I/O elements | |
201 | LLS 1 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS232/RS485 | Permanent I/O elements | |
202 | LLS 1 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS232/RS485 | Permanent I/O elements | |
203 | LLS 2 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS485 | Permanent I/O elements | |
204 | LLS 2 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS485 | Permanent I/O elements | |
210 | LLS 3 Fuel Level | 2 | Unsigned | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS485 | Permanent I/O elements | |
211 | LLS 3 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS485 | Permanent I/O elements | |
212 | LLS 4 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS485 | Permanent I/O elements | |
213 | LLS 4 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS485 | Permanent I/O elements | |
214 | LLS 5 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS485 | Permanent I/O elements | |
215 | LLS 5 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS485 | Permanent I/O elements | |
15 | Eco Score | 2 | Unsigned | 0 | 65535 | 0.01 | - | Average amount of events on some distance | Permanent I/O elements | |
113 | Battery Level | 1 | Unsigned | 0 | 100 | - | % | Battery capacity level | Permanent I/O elements | |
238 | User ID | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | MAC address of NMEA receiver device connected via Bluetooth | Permanent I/O elements | |
237 | Network Type | 1 | Unsigned | 0 | 1 | - | - | 0 - 3G
1 - GSM |
FM3001 |
Permanent I/O elements |
8 | Authorized iButton | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | If ID is shown in this I/O that means that attached iButton is in iButton List | Permanent I/O elements | |
4 | Pulse Counter Din1 | 4 | Unsigned | 0 | 4294967295 | - | - | Counts pulses, count is reset when records are saved | Permanent I/O elements | |
5 | Pulse Counter Din2 | 4 | Unsigned | 0 | 4294967295 | - | - | Counts pulses, count is reset when records are saved | Permanent I/O elements | |
263 | BT Status | 1 | Unsigned | 0 | 4 | - | - | 0 - BT is disabled
1 - BT Enabled, not device connected 2 - Device connected, BTv3 Only 3 - Device connected, BLE only 4 - Device connected, BLE + BT |
Permanent I/O elements | |
264 | Barcode ID | Variable | ASCII | 0 | 32 | - | - | Barcode ID | Permanent I/O elements | |
269 | Escort LLS Temperature #1 | 2 | Signed | -128 | 127 | - | °C | Fuel temperature | Permanent I/O elements | |
270 | Escort LLS Fuel level #1 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Permanent I/O elements | |
271 | Escort LLS Battery Voltage #1 | 2 | Unsigned | 0 | 65535 | 0.01 | V | Battery Voltage | Permanent I/O elements | |
272 | Escort LLS Temperature #2 | 2 | Signed | -128 | 127 | - | °C | Fuel temperature | Permanent I/O elements | |
273 | Escort LLS Fuel level #2 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Permanent I/O elements | |
274 | Escort LLS Battery Voltage #2 | 2 | Unsigned | 0 | 65535 | 0.01 | V | Battery Voltage | Permanent I/O elements | |
275 | Escort LLS Temperature #3 | 2 | Signed | -128 | 127 | - | °C | Fuel temperature | Permanent I/O elements | |
276 | Escort LLS Fuel level #3 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Permanent I/O elements | |
277 | Escort LLS Battery Voltage #3 | 2 | Unsigned | 0 | 65535 | 0.01 | V | Battery Voltage | Permanent I/O elements | |
278 | Escort LLS Temperature #4 | 2 | Signed | -128 | 127 | - | °C | Fuel temperature | Permanent I/O elements | |
279 | Escort LLS Fuel level #4 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Permanent I/O elements | |
280 | Escort LLS Battery Voltage #4 | 2 | Unsigned | 0 | 65535 | 0.01 | V | Battery Voltage | Permanent I/O elements | |
303 | Instant Movement | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 returns movement value | Permanent I/O elements | |
327 | UL202-02 Sensor Fuel level | 2 | Signed | -150 | 32767 | 0.1 | mm | UL202-02 Sensor Fuel level | Permanent I/O elements | |
483 | UL202-02 Sensor Status | 1 | Unsigned | 0 | 255 | - | - | UL202-02 sensor status codes | Permanent I/O elements | |
380 | Digital output 3 | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | Permanent I/O elements | |
381 | Ground Sense | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | FMB130 |
Permanent I/O elements |
387 | ISO6709 Coordinates | 34 | HEX | 0 | 0x7fffffffffffffff | - | - | ISO6709 Coordinates
Latitude, Longitude (in Degrees, Minutes and Seconds) and Altitude: IO value format: ±DDMMSS.SSSS±DDDMMSS.SSSS±AAA.AAA/ |
Permanent I/O elements | |
636 | UMTS/LTE Cell ID | 4 | Unsigned | 0 | 0xFFFFFFFF | - | - | Permanent I/O elements | ||
403 | Driver Name | 35 | Unsigned | - | - | - | - | Driver name extracted from card, displayed without delimiters ($ signs) |
Devices: [Expand] FMU126
|
Permanent I/O elements |
404 | Driver card license type | 1 | Unsigned | 0 | 8 | - | - |
None - 0 |
Devices: [Expand] FMU126
|
Permanent I/O elements |
405 | Driver Gender | 1 | Unsigned | 0 | 2 | - | - |
None - 0 |
Devices: [Expand] FMU126
|
Permanent I/O elements |
406 | Driver Card ID | 4 | Unsigned | 0 | 4294967295 | - | - |
None - 0 |
Devices: [Expand] FMU126
|
Permanent I/O elements |
407 | Driver Card Issue Year | 1 | Unsigned | - | - | - | - | Value from card as it is |
Devices: [Expand] FMU126
|
Permanent I/O elements |
408 | Driver Card Issue Year | 4 | Unsigned | 0 | 4294967295 | - | - | - |
Devices: [Expand] FMU126
|
Permanent I/O elements |
409 | Driver Status Event | 1 | Unsigned | 0 | 2 | - | - |
Registered - 0 |
Devices: [Expand] FMU126
|
Permanent I/O elements |
Eventual I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
175 | Auto Geofence | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
Eventual I/O elements | |
250 | Trip | 1 | Unsigned | 0 | 1 | - | - |
0 – trip stop |
Eventual I/O elements | |
255 | Over Speeding | 1 | Unsigned | 0 | 255 | - | km/h |
At over speeding start km/h, at over speeding end km/h |
Eventual I/O elements | |
253 | Green driving type | 1 | Unsigned | 1 | 3 | - | - |
1 – harsh acceleration |
Eventual I/O elements | |
246 | Towing | 1 | Unsigned | 0 | 1 | - | - |
0 – steady |
Eventual I/O elements | |
254 | Green Driving Value | 1 | Unsigned | 0 | 255 | acc and braking: 0.01 | G or rad | Depending on green driving type: if harsh acceleration or braking – g*100 (value 123 -> 1.23g). If Green driving source is „GPS“ – harsh cornering value is rad/s*100. If source is „Accelerometer“ – g*100. | Eventual I/O elements |