Difference between revisions of "Secure vehicle disabling"

From Wiki Knowledge Base | Teltonika GPS
Line 10: Line 10:
 
* The secure vehicle disabling solution is supported by any Teltonika FMB series tracker which has one or more digital output (DOUT) which in this scenario is used to control fuel pump of the car.  
 
* The secure vehicle disabling solution is supported by any Teltonika FMB series tracker which has one or more digital output (DOUT) which in this scenario is used to control fuel pump of the car.  
 
* The SIM card in order to get data to your server.
 
* The SIM card in order to get data to your server.
* The secure engine cut-off (SECO) functionality is only available in Teltonika FMB series GPS trackers starting with the firmware version 03.25.10.Rev.110 or higher.
+
* The secure engine cut-off (SECO) functionality is only available in Teltonika FMB series GPS trackers starting with the firmware version 03.25.10.Rev.111 or higher.
 
* FOTA WEB to remotely send the configuration to the device.
 
* FOTA WEB to remotely send the configuration to the device.
  
Line 33: Line 33:
 
Parameter ID - Parameter name GPRS settings:
 
Parameter ID - Parameter name GPRS settings:
 
[[File:GPRS settings.png|frameless|alt=|left|250x250px]]
 
[[File:GPRS settings.png|frameless|alt=|left|250x250px]]
<br>
 
 
GPRS Settings:
 
GPRS Settings:
 
<br>  
 
<br>  
Line 39: Line 38:
 
*<span style="background-color:#91d4b9;">2002</span> – APN username (if there are no APN username, empty field should be left)
 
*<span style="background-color:#91d4b9;">2002</span> – APN username (if there are no APN username, empty field should be left)
 
*<span style="background-color:#b991d4;">2003</span> – APN password (if there are no APN password, empty field should be left)
 
*<span style="background-color:#b991d4;">2003</span> – APN password (if there are no APN password, empty field should be left)
<br>  
+
<br>
 +
 
[[File:SERVER settings.png|frameless|alt=|left|250x250px]]
 
[[File:SERVER settings.png|frameless|alt=|left|250x250px]]
<br>
 
 
Server settings:
 
Server settings:
<br>  
+
<br><span style="background-color:#b9d491;">2004</span> – Domain  
*<span style="background-color:#b9d491;">2004</span> – Domain
 
 
*<span style="background-color:#d491b9;">2005</span> – Port
 
*<span style="background-color:#d491b9;">2005</span> – Port
 
*<span style="background-color:#d4b991;">2006</span> – Data sending protocol (0 – TCP, 1 – UDP)
 
*<span style="background-color:#d4b991;">2006</span> – Data sending protocol (0 – TCP, 1 – UDP)
Line 52: Line 50:
  
 
[[File:SystemsettingsSECO.png|frameless|alt=|left|622x622px]]
 
[[File:SystemsettingsSECO.png|frameless|alt=|left|622x622px]]
<br>
 
 
System settings:
 
System settings:
 +
<br>
 +
 +
*<span style="background:#E18DE7">113</span> - Data protocol
 
<br>  
 
<br>  
* 100 - Movement source
+
<br>
* 133 - Speed source
+
* 107 - Records Saving/Sending Without TS
 
* 108 - LED Indication
 
* 109 - GNSS Source
 
* 110 - Battery Charge mode
 
* 111 - Analog Input Value Range
 
* <span style="background:#E18DE7">113</span> - Data protocol
 
<br>  
 
<br>
 
 
[[File:Sleep_mode.png|alt=|frameless|left|250x250px]]
 
[[File:Sleep_mode.png|alt=|frameless|left|250x250px]]
 
<br>  
 
<br>  
Line 81: Line 73:
 
<br>  
 
<br>  
 
<br>  
 
<br>  
 +
 +
 +
 
<br>  
 
<br>  
 +
 
Sleep settings:
 
Sleep settings:
 
*<span style="background:#05CC6F">102</span> – Sleep settings(0 – Disable, 1 – Gps sleep, 2 – Deep sleep, 3 – Online Deep sleep, 4 – Ultra sleep)
 
*<span style="background:#05CC6F">102</span> – Sleep settings(0 – Disable, 1 – Gps sleep, 2 – Deep sleep, 3 – Online Deep sleep, 4 – Ultra sleep)
 
<br>  
 
<br>  
 
<br>  
 
<br>  
<br>
+
 
 
<br>  
 
<br>  
 
'''Note''': This scenario will not work with [[FMB130 Sleep modes#Deep%20Sleep%20mode|Deep Sleep]] and [[FMB130 Sleep modes#Ultra%20Deep%20Sleep%20mode|Ultra Deep Sleep]] since they disable the device's GSM module to save power.
 
'''Note''': This scenario will not work with [[FMB130 Sleep modes#Deep%20Sleep%20mode|Deep Sleep]] and [[FMB130 Sleep modes#Ultra%20Deep%20Sleep%20mode|Ultra Deep Sleep]] since they disable the device's GSM module to save power.
<br>  
+
<br>
 +
 
[[File:SECO.png|alt=|frameless|left|445x445px]]
 
[[File:SECO.png|alt=|frameless|left|445x445px]]
<br>
 
 
SECO scenario settings:
 
SECO scenario settings:
<br>  
+
<br>
 +
 
*<span style="background:#E18DE7">12250</span> – Scenario priority
 
*<span style="background:#E18DE7">12250</span> – Scenario priority
*12251 – Eventual settings (0 – Disable, 1 – Enable)
+
* 12251 – Eventual settings (0 – Disable, 1 – Enable)
 
*<span style="background:#24FFD4">12252</span> – Output Control (0 – None, 1  – DOUT1, 2 – DOUT2, 3 – DOUT3)
 
*<span style="background:#24FFD4">12252</span> – Output Control (0 – None, 1  – DOUT1, 2 – DOUT2, 3 – DOUT3)
 
*12254 - Speed (km/h)
 
*12254 - Speed (km/h)
Line 102: Line 99:
 
*12256 - Movement timeout (s)
 
*12256 - Movement timeout (s)
 
*12253 - Output Pulse (0 – Disable, 1 – Enable)
 
*12253 - Output Pulse (0 – Disable, 1 – Enable)
*12257 – DOUT ON Duration (ms)
+
* 12257 – DOUT ON Duration (ms)
 
*12258 – DOUT OFF Duration (ms)
 
*12258 – DOUT OFF Duration (ms)
*7377 - Send SMS To
+
* 7377 - Send SMS To
 
*8377 – SMS text
 
*8377 – SMS text
 
<br>
 
<br>
Line 114: Line 111:
 
<br>  
 
<br>  
 
  "  setparam <span style="background-color:#91b9d4;">2001</span>:APN;<span style="background-color:#91d4b9;">2002</span>:APN_username;<span style="background-color:#b991d4;">2003</span>:APN_password;<span style="background-color:#b9d491;">2004</span>:Domain;<span style="background-color:#d491b9;">2005</span>:Port;<span style="background-color:#d4b991;">2006</span>:0;<span style="background:#E18DE7">113</span>:1;<span style="background:#05CC6F">102</span>:1;<span style="background:#E18DE7">12250</span>:2;<span style="background:#24FFD4">12252</span>:1"
 
  "  setparam <span style="background-color:#91b9d4;">2001</span>:APN;<span style="background-color:#91d4b9;">2002</span>:APN_username;<span style="background-color:#b991d4;">2003</span>:APN_password;<span style="background-color:#b9d491;">2004</span>:Domain;<span style="background-color:#d491b9;">2005</span>:Port;<span style="background-color:#d4b991;">2006</span>:0;<span style="background:#E18DE7">113</span>:1;<span style="background:#05CC6F">102</span>:1;<span style="background:#E18DE7">12250</span>:2;<span style="background:#24FFD4">12252</span>:1"
 +
 +
==SECO SMS Command==
 +
 +
 +
Secure engine cut-off (SECO) functionality is available for device with at least one DOUT.  For SECO functionality to work, DOUT must to be selected. SECO has DOUT control priority higher than immobilizer scenario.
 +
 +
 +
SECO scenario can only be enabled or disabled by SMS commands:
 +
 +
*"secoon" - to activate SECO functionality.
 +
 +
*"secooff" - to disable SECO functionality.
 +
 +
 +
The structure of sending SMS commands: [[FMB130 SMS/GPRS Commands]]
 +
 +
===1. SMS responses ===
 +
 +
 +
To SMS command „secooff“ device will give response: „Seco off received. DOUTX off“.
 +
 +
To SMS command „secoon“ response:
 +
 +
1. „Seco on received. Waiting for conditions“.
 +
 +
2. „Seco on received. DOUTX pulsing“.
 +
 +
3. „Seco on received. DOUTX on“.
 +
 +
When response is not 3 all later SMS will be received. Example: SMS 1 received and pulse configured, then SMS 2 will be received when speed is lower than configured and SMS 3 will be received when speed reaches 0
 +
 +
 +
'''Note!'''  Sending commands to the device without DOUT will give response "SECO not available for this device". When DOUT is not selected in configuration response will be: "Error. no DOUT configured".
 +
 +
===2. SECO Pulse functionality===
 +
 +
 +
In sace SECO pulse (12253) is enabled device will not activate DOUT immediatly.
 +
 +
'''GNSS fix present''': when speed is lower than configured Speed Pulse Scenario (12259) for configured amount of time (12255), device will pulse DOUT until GNSS speed reaches configured speed (12254) then DOUT will stop pulsing and stay active (ON) until „secooff“ SMS is received.
 +
 +
 +
'''GNSS fix unavailable:''' wait until movement timeout (12256) is reached then DOUT will stay active until „secooff“ SMS is received.
 +
 +
In case SECO pulse is disabled while pulsing, device will activate DOUT.
 +
 +
===3. GNSS fix available ===
 +
 +
 +
After "secoon" SMS is received, command will be saved to the device memory and check vehicle speed. When speed is lower than configured (12254) for configured amount of time (12255), device will activate configured DOUT.
 +
 +
===4. GNSS fix unavailable===
 +
 +
 +
After "secoon" SMS is received, command will be saved to device memory and movement timeout. When movement timeout (12256) is reached, device will activate configured DOUT.
  
 
==Pharsing SECO records==
 
==Pharsing SECO records==
Line 121: Line 173:
 
====1.1.  Open [[Opening TCP/UDP port|TCP/UDP port]]====
 
====1.1.  Open [[Opening TCP/UDP port|TCP/UDP port]]====
  
==== 1.2. Go to [[Java Parser First Start Guide|Java parser first start guide]]====
+
====1.2. Go to [[Java Parser First Start Guide|Java parser first start guide]]====
 
'''2. Parsing example:'''
 
'''2. Parsing example:'''
 
{| class="nd-othertables_2" style="width:100%;"
 
{| class="nd-othertables_2" style="width:100%;"
 
|+
 
|+
! rowspan="1" style="width:100%; vertical-align: middle; text-align: center;" | Unparsed received data in hexadecimal stream
+
! rowspan="1" style="width:100%; vertical-align: middle; text-align: center;" |Unparsed received data in hexadecimal stream
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |00000000000000678E02000001774D66D5A8010F1267D220979FC600BE00C1050028<span style="background:#0b9768">018C</span>0004000400EF0100
 
| style="vertical-align: middle; text-align: center;" |00000000000000678E02000001774D66D5A8010F1267D220979FC600BE00C1050028<span style="background:#0b9768">018C</span>0004000400EF0100
Line 139: Line 191:
 
! rowspan="1" style="width:50%; vertical-align: middle; text-align: center;" |HEX Code Part
 
! rowspan="1" style="width:50%; vertical-align: middle; text-align: center;" |HEX Code Part
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" |Zero Bytes
+
| style="vertical-align: middle; text-align: center;" | Zero Bytes
 
| style="vertical-align: middle; text-align: center;" |00 00 00 00
 
| style="vertical-align: middle; text-align: center;" |00 00 00 00
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" |Data Field Length
+
| style="vertical-align: middle; text-align: center;" | Data Field Length
 
| style="vertical-align: middle; text-align: center;" |00 00 00 67
 
| style="vertical-align: middle; text-align: center;" |00 00 00 67
 
|-
 
|-
Line 148: Line 200:
 
| style="vertical-align: middle; text-align: center;" |8E (Codec 8 Extended)
 
| style="vertical-align: middle; text-align: center;" |8E (Codec 8 Extended)
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" |Number of Data 1 (Records)
+
| style="vertical-align: middle; text-align: center;" | Number of Data 1 (Records)
 
| style="vertical-align: middle; text-align: center;" |02
 
| style="vertical-align: middle; text-align: center;" |02
 
|-
 
|-
Line 160: Line 212:
 
| style="vertical-align: middle; text-align: center;" |0F 12 67 D2
 
| style="vertical-align: middle; text-align: center;" |0F 12 67 D2
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" |Latitude
+
| style="vertical-align: middle; text-align: center;" | Latitude
 
| style="vertical-align: middle; text-align: center;" |20 97 9F C6
 
| style="vertical-align: middle; text-align: center;" |20 97 9F C6
 
|-
 
|-
Line 172: Line 224:
 
| style="vertical-align: middle; text-align: center;" |05
 
| style="vertical-align: middle; text-align: center;" |05
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" |Speed
+
| style="vertical-align: middle; text-align: center;" | Speed
| style="vertical-align: middle; text-align: center;" |00 28
+
| style="vertical-align: middle; text-align: center;" | 00 28
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" |Event IO ID
+
| style="vertical-align: middle; text-align: center;" | Event IO ID
 
| style="vertical-align: middle; text-align: center;" |<span style="background:#0b9768">01 8C (AVL ID: 396, Name: Seco)</span>
 
| style="vertical-align: middle; text-align: center;" |<span style="background:#0b9768">01 8C (AVL ID: 396, Name: Seco)</span>
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" |of Total ID
+
| style="vertical-align: middle; text-align: center;" | of Total ID
 
| style="vertical-align: middle; text-align: center;" |00 04
 
| style="vertical-align: middle; text-align: center;" |00 04
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |of One Byte IO
 
| style="vertical-align: middle; text-align: center;" |of One Byte IO
| style="vertical-align: middle; text-align: center;" |00 04
+
| style="vertical-align: middle; text-align: center;" | 00 04
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |1’st IO ID
 
| style="vertical-align: middle; text-align: center;" |1’st IO ID
| style="vertical-align: middle; text-align: center;" | 00 EF (AVL ID: 239; Name: Ignition)
+
| style="vertical-align: middle; text-align: center;" |00 EF (AVL ID: 239; Name: Ignition)
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |1’st IO Value
 
| style="vertical-align: middle; text-align: center;" |1’st IO Value
Line 191: Line 243:
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |2’nd IO ID
 
| style="vertical-align: middle; text-align: center;" |2’nd IO ID
| style="vertical-align: middle; text-align: center;" | 00 F0 (AVL ID: 240; Name: Movement)
+
| style="vertical-align: middle; text-align: center;" |00 F0 (AVL ID: 240; Name: Movement)
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |2’nd IO Value
 
| style="vertical-align: middle; text-align: center;" |2’nd IO Value
Line 211: Line 263:
 
| style="vertical-align: middle; text-align: center;" |00 00
 
| style="vertical-align: middle; text-align: center;" |00 00
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" |N4 of Two Bytes IO
+
| style="vertical-align: middle; text-align: center;" | N4 of Two Bytes IO
 
| style="vertical-align: middle; text-align: center;" |00 00
 
| style="vertical-align: middle; text-align: center;" |00 00
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" |N8 of Two Bytes IO
+
| style="vertical-align: middle; text-align: center;" | N8 of Two Bytes IO
 
| style="vertical-align: middle; text-align: center;" |00 00
 
| style="vertical-align: middle; text-align: center;" |00 00
 
|-
 
|-
Line 229: Line 281:
 
| style="vertical-align: middle; text-align: center;" |0F 12 66 3
 
| style="vertical-align: middle; text-align: center;" |0F 12 66 3
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" |Latitude
+
| style="vertical-align: middle; text-align: center;" | Latitude
 
| style="vertical-align: middle; text-align: center;" |20 97 9B FF
 
| style="vertical-align: middle; text-align: center;" |20 97 9B FF
 
|-
 
|-
Line 241: Line 293:
 
| style="vertical-align: middle; text-align: center;" |05
 
| style="vertical-align: middle; text-align: center;" |05
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" |Speed
+
| style="vertical-align: middle; text-align: center;" | Speed
| style="vertical-align: middle; text-align: center;" |00 28
+
| style="vertical-align: middle; text-align: center;" | 00 28
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" |Event IO ID
+
| style="vertical-align: middle; text-align: center;" | Event IO ID
 
| style="vertical-align: middle; text-align: center;" |<span style="background:#0b9768">01 8C (AVL ID: 396, Name: Seco)</span>
 
| style="vertical-align: middle; text-align: center;" |<span style="background:#0b9768">01 8C (AVL ID: 396, Name: Seco)</span>
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" |of Total ID
+
| style="vertical-align: middle; text-align: center;" | of Total ID
 
| style="vertical-align: middle; text-align: center;" |00 04
 
| style="vertical-align: middle; text-align: center;" |00 04
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" |of One Byte IO
+
| style="vertical-align: middle; text-align: center;" | of One Byte IO
 
| style="vertical-align: middle; text-align: center;" |00 04
 
| style="vertical-align: middle; text-align: center;" |00 04
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |1’st IO ID
 
| style="vertical-align: middle; text-align: center;" |1’st IO ID
| style="vertical-align: middle; text-align: center;" | 00 EF (AVL ID: 239; Name: Ignition)
+
| style="vertical-align: middle; text-align: center;" |00 EF (AVL ID: 239; Name: Ignition)
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |1’st IO Value
 
| style="vertical-align: middle; text-align: center;" |1’st IO Value
Line 260: Line 312:
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |2’nd IO ID
 
| style="vertical-align: middle; text-align: center;" |2’nd IO ID
| style="vertical-align: middle; text-align: center;" | 00 F0 (AVL ID: 240; Name: Movement)
+
| style="vertical-align: middle; text-align: center;" |00 F0 (AVL ID: 240; Name: Movement)
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |2’nd IO Value
 
| style="vertical-align: middle; text-align: center;" |2’nd IO Value
Line 290: Line 342:
 
|-
 
|-
 
| style="vertical-align: middle; text-align: center;" |Number of Data 2 (Number of Total Records)
 
| style="vertical-align: middle; text-align: center;" |Number of Data 2 (Number of Total Records)
| style="vertical-align: middle; text-align: center;" | 02
+
| style="vertical-align: middle; text-align: center;" |02
 
|-
 
|-
| style="vertical-align: middle; text-align: center;" | CRC-16
+
| style="vertical-align: middle; text-align: center;" |CRC-16
 
| style="vertical-align: middle; text-align: center;" |00 00 A6 5F
 
| style="vertical-align: middle; text-align: center;" |00 00 A6 5F
 
|}
 
|}
  
==In platform ==
+
==In platform==
 
TAVL: Open TAVL → select client → select Street Map → select device → choose the date from which to which to show the records → push advanced → push show button and then you will see in left down corner all information.
 
TAVL: Open TAVL → select client → select Street Map → select device → choose the date from which to which to show the records → push advanced → push show button and then you will see in left down corner all information.
 
[[File:Seco 2.png|alt=|frameless|center|1155x1155px]]
 
[[File:Seco 2.png|alt=|frameless|center|1155x1155px]]
 
<br />
 
<br />
 
[[File:Seco 2.png|alt=|frameless|center|1155x1155px]]
 
[[File:Seco 2.png|alt=|frameless|center|1155x1155px]]

Revision as of 08:08, 1 March 2021

Main Page > General Information > Usage scenarios > Secure vehicle disabling

Project description

Motor vehicle theft is one of the world’s biggest concerns and the fastest growing crimes in many countries around the world. This great challenge for car rental agencies, car sharing clubs, businesses, state organizations and private car owners caused properly losses of over 6 billion US dollar globally in 2018. Luckily for them, Teltonika GPS trackers gave a remote secure engine cut-off (SECO) functionality that can help to recover a stolen vehicle and prevent the loss.

We glad that you decided to test our “Secure vehicle disabling” solution.

Here you will find how to prepare and to test this solution.

What you need for a solution?

  • The secure vehicle disabling solution is supported by any Teltonika FMB series tracker which has one or more digital output (DOUT) which in this scenario is used to control fuel pump of the car.
  • The SIM card in order to get data to your server.
  • The secure engine cut-off (SECO) functionality is only available in Teltonika FMB series GPS trackers starting with the firmware version 03.25.10.Rev.111 or higher.
  • FOTA WEB to remotely send the configuration to the device.

Installation

It’s important to well hide tracker, so it would not be a simple task for the thieves to find and unplug it. But also, please do not forget to follow mounting recommendations as well. Although devices have high gain antennas it’s important to mount devices with stickers on top and in metal-free space. The device should be firmly fixed to the surface or cables. Please make sure, that device is not fixed to heat emitting or moving parts.


During installation please follow recommendations in order to avoid damaging device and vehicle:

  • Wires should be connected while the module is not plugged in.
  • Be sure that after the car computer falls asleep, power is still available on the chosen wire. Depending on the car, this may happen in a 5 to 30 minutes period.
  • When the module is connected, be sure to measure the voltage again if it did not decrease.
  • The ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.

Configuration

1. Prerequisites:

1.1. Read through First start guide

1.2. Understanding of possible Sleep modes.

2. Configuring SECO scenario

Parameter ID - Parameter name GPRS settings:

GPRS Settings:

  • 2001 – APN
  • 2002 – APN username (if there are no APN username, empty field should be left)
  • 2003 – APN password (if there are no APN password, empty field should be left)


Server settings:
2004 – Domain

  • 2005 – Port
  • 2006 – Data sending protocol (0 – TCP, 1 – UDP)


After successful GPRS/SERVER settings configuration, FMB130 device will synchronize time and update records to the configured server. Time intervals and default I/O elements can be changed by using Teltonika Configurator or SMS parameters.

System settings:

  • 113 - Data protocol




















Sleep settings:

  • 102 – Sleep settings(0 – Disable, 1 – Gps sleep, 2 – Deep sleep, 3 – Online Deep sleep, 4 – Ultra sleep)




Note: This scenario will not work with Deep Sleep and Ultra Deep Sleep since they disable the device's GSM module to save power.

SECO scenario settings:

  • 12250 – Scenario priority
  • 12251 – Eventual settings (0 – Disable, 1 – Enable)
  • 12252 – Output Control (0 – None, 1 – DOUT1, 2 – DOUT2, 3 – DOUT3)
  • 12254 - Speed (km/h)
  • 12259 - Speed Pulse Scenario (km/h)
  • 12255 - Speed check period (s)
  • 12256 - Movement timeout (s)
  • 12253 - Output Pulse (0 – Disable, 1 – Enable)
  • 12257 – DOUT ON Duration (ms)
  • 12258 – DOUT OFF Duration (ms)
  • 7377 - Send SMS To
  • 8377 – SMS text






Quick start: From default configuration to SECO detection in one SMS:

"  setparam 2001:APN;2002:APN_username;2003:APN_password;2004:Domain;2005:Port;2006:0;113:1;102:1;12250:2;12252:1"

SECO SMS Command

Secure engine cut-off (SECO) functionality is available for device with at least one DOUT. For SECO functionality to work, DOUT must to be selected. SECO has DOUT control priority higher than immobilizer scenario.


SECO scenario can only be enabled or disabled by SMS commands:

  • "secoon" - to activate SECO functionality.
  • "secooff" - to disable SECO functionality.


The structure of sending SMS commands: FMB130 SMS/GPRS Commands

1. SMS responses

To SMS command „secooff“ device will give response: „Seco off received. DOUTX off“.

To SMS command „secoon“ response:

1. „Seco on received. Waiting for conditions“.

2. „Seco on received. DOUTX pulsing“.

3. „Seco on received. DOUTX on“.

When response is not 3 all later SMS will be received. Example: SMS 1 received and pulse configured, then SMS 2 will be received when speed is lower than configured and SMS 3 will be received when speed reaches 0


Note! Sending commands to the device without DOUT will give response "SECO not available for this device". When DOUT is not selected in configuration response will be: "Error. no DOUT configured".

2. SECO Pulse functionality

In sace SECO pulse (12253) is enabled device will not activate DOUT immediatly.

GNSS fix present: when speed is lower than configured Speed Pulse Scenario (12259) for configured amount of time (12255), device will pulse DOUT until GNSS speed reaches configured speed (12254) then DOUT will stop pulsing and stay active (ON) until „secooff“ SMS is received.


GNSS fix unavailable: wait until movement timeout (12256) is reached then DOUT will stay active until „secooff“ SMS is received.

In case SECO pulse is disabled while pulsing, device will activate DOUT.

3. GNSS fix available

After "secoon" SMS is received, command will be saved to the device memory and check vehicle speed. When speed is lower than configured (12254) for configured amount of time (12255), device will activate configured DOUT.

4. GNSS fix unavailable

After "secoon" SMS is received, command will be saved to device memory and movement timeout. When movement timeout (12256) is reached, device will activate configured DOUT.

Pharsing SECO records

1.Prerequisites:

1.1. Open TCP/UDP port

1.2. Go to Java parser first start guide

2. Parsing example:

Unparsed received data in hexadecimal stream
00000000000000678E02000001774D66D5A8010F1267D220979FC600BE00C1050028018C0004000400EF0100

F00100B300018C010000000000000000000001774D66D990010F12663120979BFF00BE00C1050028018C0004

000400EF0100F00100B300018C020000000000000000020000A65F

AVL Data Packet
AVL Data Packet Part HEX Code Part
Zero Bytes 00 00 00 00
Data Field Length 00 00 00 67
Codec ID 8E (Codec 8 Extended)
Number of Data 1 (Records) 02
Timestamp 00 00 01 77 4D 66 D5 A8 (Friday, January 29, 2021 9:08:41 AM)
Priority 01
Longitude 0F 12 67 D2
Latitude 20 97 9F C6
Altitude 00 BE
Angle 00 C1
Satellites 05
Speed 00 28
Event IO ID 01 8C (AVL ID: 396, Name: Seco)
of Total ID 00 04
of One Byte IO 00 04
1’st IO ID 00 EF (AVL ID: 239; Name: Ignition)
1’st IO Value 01
2’nd IO ID 00 F0 (AVL ID: 240; Name: Movement)
2’nd IO Value 01
3’th IO ID 00 B3 (AVL ID: 179; Name: Digital Output 1)
3’th IO Value 00
4’th IO ID 01 8C (AVL ID: 396, Name: Seco)
4’th IO Value 01 ( 0 - SECO DOUT OFF; 1- SECO DOUT pulsing; 2 - SECO DOUT ON)
N2 of Two Bytes IO 00 00
N4 of Two Bytes IO 00 00
N8 of Two Bytes IO 00 00
NX of X Byte IO 00 00
Timestamp 00 00 01 77 4D 66 D9 90 (Friday, January 29, 2021 9:08:42 AM)
Priority 01
Longitude 0F 12 66 3
Latitude 20 97 9B FF
Altitude 00 BE
Angle 00 C1
Satellites 05
Speed 00 28
Event IO ID 01 8C (AVL ID: 396, Name: Seco)
of Total ID 00 04
of One Byte IO 00 04
1’st IO ID 00 EF (AVL ID: 239; Name: Ignition)
1’st IO Value 01
2’nd IO ID 00 F0 (AVL ID: 240; Name: Movement)
2’nd IO Value 01
3’th IO ID 00 B3 (AVL ID: 179; Name: Digital Output 1)
3’th IO Value 00
4’th IO ID 01 8C (AVL ID: 396, Name: Seco)
4’th IO Value 02 ( 0 - SECO DOUT OFF; 1- SECO DOUT pulsing; 2 - SECO DOUT ON)
N2 of Two Bytes IO 00 00
N4 of Two Bytes IO 00 00
N8 of Two Bytes IO 00 00
NX of X Byte IO 00 00
Number of Data 2 (Number of Total Records) 02
CRC-16 00 00 A6 5F

In platform

TAVL: Open TAVL → select client → select Street Map → select device → choose the date from which to which to show the records → push advanced → push show button and then you will see in left down corner all information.