From Teltonika Telematics Wiki
|
|
Line 1,125: |
Line 1,125: |
| | style="text-align: center; vertical-align: center;" rowspan=2 |Dout control | | | style="text-align: center; vertical-align: center;" rowspan=2 |Dout control |
| |- | | |- |
| | style="text-align: center; vertical-align: center;" rowspan=2 |1- Enabled | | | style="text-align: center; vertical-align: center;" |1 - Enabled |
| |- | | |- |
| ! style="text-align: center; vertical-align: center;" |11705 | | ! style="text-align: center; vertical-align: center;" |11705 |
Revision as of 10:59, 13 April 2018
System parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
100
|
Uint8
|
0
|
0
|
2
|
0 – Ignition
|
Movement source
|
1 – Movement
|
2 – GPS
|
106
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Static navigation
|
1 – Enable
|
107
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Send/Save records without TS
|
1 – Enable
|
108
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
LED Indication
|
1 – Enable
|
109
|
Uint8
|
10
|
1
|
15
|
0 – Undefined
|
GNSS source
|
1 – Beidou only
|
2 – Glonass only
|
3 – Glonass and Beidou not allowed
|
4 – Galileo only
|
5 – Galileo and Beidou
|
6 – Galileo and Glonass
|
7 – Galileo, Glonass and Beidou not allowed
|
8 – Gps only
|
9 – Gps and Beidou
|
10 – Gps and Glonass
|
11 – Gps, Glonass and Beidou not allowed
|
12 – Gps and Galileo
|
13 – Gps, Galileo and Beidou
|
14 – Gps, Galileo and Glonass
|
15 – Gps, Galileo, Glonass and Beidou and not allowed
|
110
|
Uint8
|
0
|
0
|
1
|
0 – On need
|
Battery charge mode|
|
1 – After ignition on
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
102
|
Uint8
|
2
|
0
|
2
|
0 – Disable
|
Sleep settings
|
1 – Gps sleep
|
2 – Deep sleep
|
103
|
Uint16
|
1
|
1
|
3000
|
Minutes
|
Timeout
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
101
|
Uint8
|
0
|
0
|
2
|
0 – Power voltage
|
Ignition settings
|
1 – Din 1
|
2 – Accelerometer
|
104
|
Uint16
|
30000
|
0
|
30000
|
mV
|
High voltage
|
105
|
Uint16
|
13200
|
0
|
29999
|
mV
|
Low voltage
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
900
|
Uint8
|
1
|
0
|
3
|
0 – Gps only
|
Synchronization settings
|
1 – NITZ and NTP
|
2 – NTP
|
3 – NITZ
|
901
|
Uint8
|
0
|
0
|
24
|
Hours
|
NTP Resync
|
902
|
Char
|
"avl1.teltonika.lt"
|
0
|
55
|
String
|
NTP server 1
|
903
|
Char
|
"pool.ntp.org"
|
0
|
55
|
String
|
NTP server 2
|
GPRS parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1000
|
Uint32
|
5
|
0
|
259200
|
Seconds
|
Open link timeout
|
1001
|
Uint16
|
30
|
5
|
300
|
Seconds
|
Response timeout
|
1002
|
Uint8
|
0
|
0
|
1
|
0 – Newest
|
Sort by
|
1 – Oldest
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
2000
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
GPRS context
|
1 – Enable
|
2001
|
Char
|
""
|
0
|
32
|
String
|
APN
|
2002
|
Char
|
""
|
0
|
32
|
String
|
APN username
|
2003
|
Char
|
""
|
0
|
32
|
String
|
APN password
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
2004
|
Char
|
""
|
0
|
55
|
String
|
Domain
|
2005
|
Uint16
|
0
|
0
|
65535
|
Number
|
Port
|
2006
|
Uint8
|
1
|
0
|
1
|
0 – TCP
|
Protocol
|
1 – UDP
|
SMS/Call settings
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3000
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Allow SMS data sending
|
1 – Enable
|
3001
|
Char
|
""
|
0
|
16
|
String
|
Data Send Number
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3003
|
Char
|
""
|
0
|
5
|
String
|
Login
|
3004
|
Char
|
""
|
0
|
5
|
String
|
Password
|
3006
|
Uint16
|
UTC+00:00
|
UTC-12:00
|
UTC+13:00
|
Time zone
|
SMS event Time Zone
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3005
|
Uint8
|
0
|
0
|
4
|
0 – Do nothing
|
Incoming call action
|
1 – Hangup
|
2 – Report position
|
3 – Spy call
|
4 – Auto answer
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3007
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Outgoing call trigger
|
1 – DIN 1
|
2 – Crash event
|
3 – DIN1 and Crash event
|
3008
|
Uint8
|
0
|
0
|
10
|
GSM number
|
GSM number index
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
4000-4009
|
Char
|
""
|
0
|
16
|
String
|
Authorized number
|
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
6000-6009
|
Char
|
""
|
0
|
16
|
String
|
Predefined number
|
GSM operators
Data acquisition mode parameters
Home Network GSM operator code "Vehicle on STOP" parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10000
|
Uint16
|
3600
|
0
|
65535
|
Min Period
|
10004
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10055
|
Uint16
|
120
|
0
|
65535
|
Send Period
|
Home Network GSM operator code "Vehicle MOVING" parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10050
|
Uint16
|
300
|
0
|
65535
|
Min Period
|
10051
|
Uint16
|
100
|
0
|
65535
|
Min Distance
|
10052
|
Uint8
|
10
|
0
|
180
|
Min Angle
|
10053
|
Uint8
|
10
|
0
|
100
|
Min Speed Delta
|
10054
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10055
|
Uint16
|
120
|
0
|
65535
|
Send Period
|
Roaming Network GSM operator code "Vehicle on STOP" parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10100
|
Uint16
|
3600
|
0
|
65535
|
Min Period
|
10104
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10105
|
Uint16
|
0
|
0
|
65535
|
Send Period
|
Roaming Network GSM operator code "Vehicle MOVING" parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10150
|
Uint16
|
300
|
0
|
65535
|
Min Period
|
10151
|
Uint16
|
100
|
0
|
65535
|
Min Distance
|
10152
|
Uint8
|
10
|
0
|
180
|
Min Angle
|
10153
|
Uint8
|
10
|
0
|
100
|
Min Speed Delta
|
10154
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10155
|
Uint16
|
0
|
0
|
65535
|
Send Period
|
Unknown Network GSM operator code "Vehicle on STOP" parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10200
|
Uint16
|
3600
|
0
|
65535
|
Min Period
|
10204
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10205
|
Uint16
|
120
|
0
|
65535
|
Send Period
|
Unknown Network GSM operator code "Vehicle MOVING" parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10250
|
Uint16
|
300
|
0
|
65535
|
Min Period
|
10251
|
Uint16
|
100
|
0
|
65535
|
Min Distance
|
10252
|
Uint8
|
10
|
0
|
180
|
Min Angle
|
10253
|
Uint8
|
10
|
0
|
100
|
Min Speed Delta
|
10254
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10255
|
Uint16
|
0
|
0
|
65535
|
Send Period
|
Features parameters
Green driving parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11000
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario settings
|
1 – Low priority
|
2 – High priority
|
3 – Panic priority
|
11004
|
Uint8
|
25
|
25
|
85
|
mG
|
Max acceleration
|
11005
|
Uint8
|
35
|
25
|
85
|
mG
|
Max braking
|
11006
|
Uint8
|
30
|
10
|
100
|
mG
|
Max cornering
|
11007
|
Uint8
|
0
|
0
|
1
|
0 – GPS
|
Source
|
1 – Accelerometer
|
11008
|
uint8
|
0
|
0
|
1
|
Enable/Disable
|
Duration
|
11003
|
Uint8
|
0
|
0
|
1
|
0 – None
|
Output control
|
1 – DOUT 1
|
11001
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT ON duration
|
11002
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT OFF duration
|
7034
|
Uint8
|
0
|
0
|
10
|
Phone number
|
Send SMS to
|
8034
|
String
|
"Green Driving"
|
0
|
160
|
Text
|
Sms text
|
Overspeeding scenario parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11100
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario settings
|
1 – Low priority
|
2 – High priority
|
3 – Panic priority
|
11104
|
Uint16
|
90
|
0
|
260
|
km/h
|
Max speed
|
11103
|
Uint8
|
0
|
0
|
1
|
0 – None
|
Output control
|
1 – DOUT 1
|
11101
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT ON duration
|
11102
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT OFF duration
|
7032
|
Uint8
|
0
|
0
|
10
|
Phone number
|
Send SMS to
|
8032
|
String
|
"Overspeeding"
|
0
|
160
|
Text
|
Sms text
|
Jamming scenario parameters
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11300
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario settings
|
1 – Low priority
|
2 – High priority
|
3 – Panic priority
|
11303
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Eventual records
|
1 – Enable
|
11304
|
Uint8
|
0
|
0
|
1
|
0 – None |
Output control
|
1 – DOUT 1
|
11301
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT ON duration
|
11302
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT OFF duration
|
11305
|
Uint16
|
60
|
0
|
65535
|
Seconds
|
Timeout
|
Immobilizer scenario parameters
Trip scenario parameters
DOUT control via call scenario parameters
iButton read notification
Parameted ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11704
|
Uint8_t
|
0
|
0
|
1
|
0 - Disabled
|
Dout control
|
1 - Enabled
|
11705
|
Uint16_t
|
200
|
100
|
50000
|
ms
|
Dout duration
|
11706
|
Uint8_t
|
0
|
0
|
1
|
0 - Disabled
|
iButton notification list
|
1 - Enabled
|
11707
|
Uint8_t
|
0
|
0
|
1
|
0-Disabled
|
Depend on ignition
|
1- Enabled
|
AutoGeofencing scenario parameters
Manual Geofence
First Geozone parameters
Other Geozones
GPS Fuel counter
Accelerometer features
Unplug Detection
Towing Detection
Crash Detection
Excessive Idling
Bluetooth
iButton List
I/O parameters
OBD II (Bluetooth)