Template:FMB Device Family Parameter list: Difference between revisions

From Teltonika Telematics Wiki
mNo edit summary
Line 1,416: Line 1,416:
==OBD II (Bluetooth)==
==OBD II (Bluetooth)==
==LVCAN==
==LVCAN==
==RS232/RS485==

Revision as of 12:35, 13 April 2018

System parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
100 Uint8 0 0 2 0 – Ignition Movement source
1 – Movement
2 – GPS
106 Uint8 1 0 1 0 – Disable Static navigation
1 – Enable
107 Uint8 0 0 1 0 – Disable Send/Save records without TS
1 – Enable
108 Uint8 1 0 1 0 – Disable LED Indication
1 – Enable
109 Uint8 10 1 15 0 – Undefined GNSS source
1 – Beidou only
2 – Glonass only
3 – Glonass and Beidou not allowed
4 – Galileo only
5 – Galileo and Beidou
6 – Galileo and Glonass
7 – Galileo, Glonass and Beidou not allowed
8 – Gps only
9 – Gps and Beidou
10 – Gps and Glonass
11 – Gps, Glonass and Beidou not allowed
12 – Gps and Galileo
13 – Gps, Galileo and Beidou
14 – Gps, Galileo and Glonass
15 – Gps, Galileo, Glonass and Beidou and not allowed
110 Uint8 0 0 1 0 – On need Battery charge mode|
1 – After ignition on
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
102 Uint8 2 0 2 0 – Disable Sleep settings
1 – Gps sleep
2 – Deep sleep
103 Uint16 1 1 3000 Minutes Timeout
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
101 Uint8 0 0 2 0 – Power voltage Ignition settings
1 – Din 1
2 – Accelerometer
104 Uint16 30000 0 30000 mV High voltage
105 Uint16 13200 0 29999 mV Low voltage


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
900 Uint8 1 0 3 0 – Gps only Synchronization settings
1 – NITZ and NTP
2 – NTP
3 – NITZ
901 Uint8 0 0 24 Hours NTP Resync
902 Char "avl1.teltonika.lt" 0 55 String NTP server 1
903 Char "pool.ntp.org" 0 55 String NTP server 2

GPRS parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1000 Uint32 5 0 259200 Seconds Open link timeout
1001 Uint16 30 5 300 Seconds Response timeout
1002 Uint8 0 0 1 0 – Newest Sort by
1 – Oldest
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2000 Uint8 1 0 1 0 – Disable GPRS context
1 – Enable
2001 Char "" 0 32 String APN
2002 Char "" 0 32 String APN username
2003 Char "" 0 32 String APN password
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2004 Char "" 0 55 String Domain
2005 Uint16 0 0 65535 Number Port
2006 Uint8 1 0 1 0 – TCP Protocol
1 – UDP

SMS/Call settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3000 Uint8 0 0 1 0 – Disable Allow SMS data sending
1 – Enable
3001 Char "" 0 16 String Data Send Number
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3003 Char "" 0 5 String Login
3004 Char "" 0 5 String Password
3006 Uint16 UTC+00:00 UTC-12:00 UTC+13:00 Time zone SMS event Time Zone
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3005 Uint8 0 0 4 0 – Do nothing Incoming call action
1 – Hangup
2 – Report position
3 – Spy call
4 – Auto answer
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3007 Uint8 0 0 3 0 – Disable Outgoing call trigger
1 – DIN 1
2 – Crash event
3 – DIN1 and Crash event
3008 Uint8 0 0 10 GSM number GSM number index
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
4000-4009 Char "" 0 16 String Authorized number
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
6000-6009 Char "" 0 16 String Predefined number

GSM operators

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
5000-5049 Uint32 0 0 999999 Number Operator code

Data acquisition mode parameters

Home Network GSM operator code "Vehicle on STOP" parameters

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10000 Uint16 3600 0 65535 Min Period
10004 Uint8 1 1 255 Min Saved Records
10055 Uint16 120 0 65535 Send Period

Home Network GSM operator code "Vehicle MOVING" parameters


Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10050 Uint16 300 0 65535 Min Period
10051 Uint16 100 0 65535 Min Distance
10052 Uint8 10 0 180 Min Angle
10053 Uint8 10 0 100 Min Speed Delta
10054 Uint8 1 1 255 Min Saved Records
10055 Uint16 120 0 65535 Send Period

Roaming Network GSM operator code "Vehicle on STOP" parameters


Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10100 Uint16 3600 0 65535 Min Period
10104 Uint8 1 1 255 Min Saved Records
10105 Uint16 0 0 65535 Send Period

Roaming Network GSM operator code "Vehicle MOVING" parameters


Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10150 Uint16 300 0 65535 Min Period
10151 Uint16 100 0 65535 Min Distance
10152 Uint8 10 0 180 Min Angle
10153 Uint8 10 0 100 Min Speed Delta
10154 Uint8 1 1 255 Min Saved Records
10155 Uint16 0 0 65535 Send Period

Unknown Network GSM operator code "Vehicle on STOP" parameters


Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10200 Uint16 3600 0 65535 Min Period
10204 Uint8 1 1 255 Min Saved Records
10205 Uint16 120 0 65535 Send Period

Unknown Network GSM operator code "Vehicle MOVING" parameters


Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10250 Uint16 300 0 65535 Min Period
10251 Uint16 100 0 65535 Min Distance
10252 Uint8 10 0 180 Min Angle
10253 Uint8 10 0 100 Min Speed Delta
10254 Uint8 1 1 255 Min Saved Records
10255 Uint16 0 0 65535 Send Period

Features parameters

Green driving parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11000 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11004 Uint8 25 25 85 mG Max acceleration
11005 Uint8 35 25 85 mG Max braking
11006 Uint8 30 10 100 mG Max cornering
11007 Uint8 0 0 1 0 – GPS Source
1 – Accelerometer
11008 uint8 0 0 1 Enable/Disable Duration
11003 Uint8 0 0 1 0 – None Output control
1 – DOUT 1
11001 Int32 200 0 2147483647 Milliseconds DOUT ON duration
11002 Int32 200 0 2147483647 Milliseconds DOUT OFF duration
7034 Uint8 0 0 10 Phone number Send SMS to
8034 String "Green Driving" 0 160 Text Sms text

Overspeeding scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11100 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11104 Uint16 90 0 260 km/h Max speed
11103 Uint8 0 0 1 0 – None Output control
1 – DOUT 1
11101 Int32 200 0 2147483647 Milliseconds DOUT ON duration
11102 Int32 200 0 2147483647 Milliseconds DOUT OFF duration
7032 Uint8 0 0 10 Phone number Send SMS to
8032 String "Overspeeding" 0 160 Text Sms text

Jamming scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11300 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11303 Uint8 1 0 1 0 – Disable Eventual records
1 – Enable
11304 Uint8 0 0 1 0 – None Output control
1 – DOUT 1
11301 Int32 200 0 2147483647 Milliseconds DOUT ON duration
11302 Int32 200 0 2147483647 Milliseconds DOUT OFF duration
11305 Uint16 60 0 65535 Seconds Timeout

Immobilizer scenario parameters


Trip scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11800 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11801 Uint8 1 0 1 0 – Disable Eventual records
1 – Enable
11802 Uint8 0 0 1 0 – Continuous Mode
1 – Between records
11803 Uint8 5 0 255 km/h Start speed
11804 Uint16 60 0 65535 Seconds Ignition off timeout
7031 Uint8 0 0 10 Phone number Send SMS to
8031 String "Trip" 0 160 Text Sms text

DOUT control via call scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
12000 Uint8 0 0 1 0 – None Digital Output control
1 – DOUT 1
12001 Uint8 0 0 1 0 – None DOUT deactivation
1 – DIN 1
12002 Int32 5 0 2147483647 Seconds Duration timeout

iButton read notification

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11704 Uint8_t 0 0 1 0 - Disabled Dout control
1 - Enabled
11705 Uint16_t 200 100 50000 ms Dout duration
11706 Uint8_t 0 0 1 0 - Disabled iButton notification list
1 - Enabled
11707 Uint8_t 0 0 1 0 - Disabled Depend on ignition
1 - Enabled

AutoGeofencing scenario parameters

Manual Geofence

First Geozone parameters

Other Geozones


GPS Fuel counter

Accelerometer features

Unplug Detection

Towing Detection


Crash Detection


Excessive Idling


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11200 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11203 Uint8 1 0 1 0 – Disable Eventual records
1 – Enable
11205 Uint8 5 0 255 Seconds Time to stoped
11206 Uint8 2 0 255 Seconds Time to moving
11204 Uint8 0 0 1 0 – None Output control
1 – DOUT 1
11201 Int32 200 0 2147483647 Milliseconds DOUT ON duration
11202 Int32 200 0 2147483647 Milliseconds DOUT OFF duration
7033 Uint8 0 0 10 Phone number Send SMS to
8033 String "Idling Event" 0 160 Text Sms text

Bluetooth

iButton List

I/O parameters

OBD II (Bluetooth)

LVCAN

RS232/RS485