Difference between revisions of "FMC130 Product Change Notifications"
Line 2: | Line 2: | ||
| product_name = FMC130 tracking device | | product_name = FMC130 tracking device | ||
}} | }} | ||
+ | |||
+ | ==2023.02.02: Base firmware update== | ||
+ | We would like to inform you about the base firmware update for FMC130 starting from February 2nd, 2023. New production firmware version will be '''03.27.13.Rev.443''' | ||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Change description | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Change type | ||
+ | | colspan="2" style="text-align: left; background: white;" |Firmware update | ||
+ | |- | ||
+ | | rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description | ||
+ | | colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Old version: <br> 03.27.13.Rev.54 | ||
+ | | style="text-align: left; background: white;" |New version: <br> 03.27.13.Rev.443 | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Change reasons | ||
+ | | colspan="2" style="text-align: left; background: white;" |FMC130 base firmware version update for modifications with SLM320-LA module, SLM320-E1 module and SLM320-E2 module | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" | Product release date | ||
+ | | colspan="2" style="text-align: left; background: white;" |2023 February | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Affected products | ||
+ | |- | ||
+ | | style="width: 221px; text-align: left; background: white;" |Model | ||
+ | | style="width: 448px; text-align: left; background: white;" |Affected order codes | ||
+ | | style="width: 448px; text-align: left; background: white;" | Order code changes | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |FMC130 | ||
+ | | style="text-align: left; background: white;" |FMC130******* with 03.27.13.Rev.54 will be replaced to FMC130******* with base firmware | ||
+ | | style="text-align: left; background: white;" |New firmware version | ||
+ | |- | ||
+ | |} | ||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Change impact | ||
+ | |- | ||
+ | | style="width: 221px; text-align: left; background: white;" |Risk assessment | ||
+ | | colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Suggested implementation plan | ||
+ | | colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
==2023.02.02: Changes in side frame for the battery placement== | ==2023.02.02: Changes in side frame for the battery placement== |
Revision as of 10:18, 3 February 2023
Main Page > Advanced Trackers > FMC130 > FMC130 Product Change NotificationsProduct change notifications (PCN) is the way of informing customers of upcoming changes related to Teltonika products. This includes outward appearance adjustments, hardware improvements, firmware changes, changes to package contents, etc. This page stores information regarding changes to the FMC130 tracking device. Below you will find a list of both upcoming and already implemented changes sorted from newest to oldest (top to bottom).
2023.02.02: Base firmware update
We would like to inform you about the base firmware update for FMC130 starting from February 2nd, 2023. New production firmware version will be 03.27.13.Rev.443
Change description | ||
---|---|---|
Change type | Firmware update | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata | |
Old version: 03.27.13.Rev.54 |
New version: 03.27.13.Rev.443 | |
Change reasons | FMC130 base firmware version update for modifications with SLM320-LA module, SLM320-E1 module and SLM320-E2 module | |
Product release date | 2023 February |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130******* with 03.27.13.Rev.54 will be replaced to FMC130******* with base firmware | New firmware version |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
2023.02.02: Changes in side frame for the battery placement
We would like to inform you that the side frame for the battery placement is included, helping to determine the exact location of the battery. Also, minor design changes are made to improve both case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices. The updates in the factory are being implemented in February, 2023.
Change description | ||
---|---|---|
Change type | Internal | |
Detailed description | The side frame for the battery placement is included, helping to determine the exact location of the battery. Also, minor design changes are made to improve both case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices. | |
Old Version: | New Version: | |
Change reasons | The battery placement is improved with a side frame, helping to determine the exact location of the battery. Minor design changes are made for case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices. | |
Product release date | February, 2023 |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, FMM150 | FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, FMM150 all codes | Updated the battery placement with the side frame as well as minor design changes for case production and assembly |
Change impact | ||
---|---|---|
Risk assessment | During the transition period clients might receive devices with old case design used in manufacture | |
Suggested implementation plan | Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process. |
Acknowledgement of PCN receipt | ||
---|---|---|
If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above. |
2022.10.01: Bluetooth Improvement
We would like to inform you, that Bluetooth performance for the FMC130 device will be updated in the factory from October, 2022.
Change description | ||
---|---|---|
Change type | Internal | |
Detailed description | BLE antenna has been improved FMC125, FMC225, FMC230 and FMC130 devices. | |
Old version: |
New version: | |
Change reasons | Bluetooth antennas are improved for FMC125, FMC225, FMC230 and FMC130 devices ensuring better signal strength. | |
Product release date | October, 2022 |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FCM130 all codes | Updated BLE antenna |
Change impact | ||
---|---|---|
Risk assessment | No risk factors encountered with this change. | |
Suggested implementation plan | Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process. | |
Acknowledgement of PCN receipt | ||
If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above. |
2022.03.18: Base firmware update
We would like to inform you about the base firmware update for FMC130 starting from March 18th, 2022. New production firmware version will be 03.27.13.Rev.54
Change description | ||
---|---|---|
Change type | Firmware update and order codes changes | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata | |
Old version: FMC130 03.27.07.Rev.252 |
New version: FMC130 03.27.13.Rev.54 | |
Change reasons | FMC130 base firmware version update for modifications with SLM320-L module and SLM320-E2 module | |
Product release date | 2022 March |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC13064***** order will be replaced to FMC1304O**** with base firmware FMC1305X***** order will be replaced to FMC130KY**** with base firmware |
New firmware version |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
2021.08.19: Base firmware update
We would like to inform you about the base firmware update for FMC130 starting from August 19th, 2021. New production firmware version will be 03.27.07.Rev.00
Change description | ||
---|---|---|
Change type | Firmware update | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata | |
Old version: FMC130 03.27.04.Rev.01 |
New version: FMC130 03.27.07.Rev.00 | |
Change reasons | FMC130 base firmware version update | |
Product release date | 2021 August |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130******* order codes with base Firmware | Update firmware |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
2021.03.16: Base firmware update
We would like to inform you about the base firmware update for FMC130 starting from March 16th, 2021. The new production firmware version will be 03.27.04.Rev.01.
Change description | ||
---|---|---|
Change type | Firmware update | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata | |
Old version: FMC130 03.27.03.Rev.02 |
New version: FMC130 03.27.04.Rev.01 | |
Change reasons | FMC130 base firmware version update | |
Product release date | 2021 March 16th. |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130******* order codes with base Firmware | Update firmware |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
2021.02.18: Base firmware update
We would like to inform you about the base firmware update for FMC130 starting from February 18th, 2021. The new production firmware version will be 03.27.03.Rev.02.
Change description | ||
---|---|---|
Change type | Firmware update | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata | |
Old version: FMC130 03.27.02.Rev.00 |
New version: FMC130 03.27.03.Rev.02 | |
Change reasons | FMC130 base firmware version update | |
Product release date | 2021 February 18th. |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130******* order codes with base Firmware | Update firmware |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
2020.09.25: Base firmware update
We would like to inform you about the base firmware update for FMC130 starting from September 25th, 2020. The new production firmware version will be 03.27.02.Rev.01.
Change description | ||
---|---|---|
Change type | Firmware update. | |
Detailed description | Key improvements from last production firmware are listed in errata: FMC130 firmware errata | |
Old version:
FMC130 03.25.10.Rev.175 |
New version:
FMC130 03.27.02.Rev.01 | |
Change reasons | FMC130 base firmware version update for EMEA region. | |
Product release date | 2020 September 25th. |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130C5**** order codes with base Firmware | Update firmware |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
2019.11.28: Top Device Marking Changes
We would like to inform you, that tampography of the FMC130 device was updated to engraving in the factory.
Change description | ||
---|---|---|
Change type | External/visual | |
Detailed description | Device marking changed from tampography to laser printing. Information provided on module will remain the same | |
Old Version: |
New Version: | |
Change reasons | To improve manufacturing speed, efficiency and reliability
To increase quality, precision and durability of marking. | |
Product release date | Planned date: 2019 December |
Affected products | ||
---|---|---|
Model | all codes with standard marking | Order code changes |
FMC130 | FMC130******* | No changes |
Change impact | ||
---|---|---|
Risk assessment | No risk factors encountered with this change | |
Suggested implementation plan | No implementation plan needed |
Acknowledgement of PCN receipt | ||
---|---|---|
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above |