Difference between revisions of "Advanced Pulse Counter"

From Wiki Knowledge Base | Teltonika GPS
Line 8: Line 8:
 
# Frequency is measured by counting pulses over time period (997 ms). Method is used for frequencies higher than 100 Hz.
 
# Frequency is measured by counting pulses over time period (997 ms). Method is used for frequencies higher than 100 Hz.
 
# Frequency is measured by measuring time between pulses. Method is used for frequencies lower than 100 Hz.
 
# Frequency is measured by measuring time between pulses. Method is used for frequencies lower than 100 Hz.
 +
When 2kHz pulse counter is enabled, all other scenarios '''will ignore''' corresponding DIN state, except DIN1 which can be used to wakeup device from Deep Sleep.
  
 
== Parameter values ==
 
== Parameter values ==
Line 24: Line 25:
 
|50Hz
 
|50Hz
 
|2kHz
 
|2kHz
|-
 
|FMB010/FMB001/FMB002/FMB020/FMB003
 
| +
 
|
 
|
 
|
 
|
 
|
 
 
|-
 
|-
 
|FMB110/FMB120/FMB130/FMB140
 
|FMB110/FMB120/FMB130/FMB140

Revision as of 11:30, 24 February 2023

Functionality description

This functionality was added in 03.28.04.Rev.00 firmware version.

If this function is active, then all other settings associated with the this input are disabled.

Frequency measurement can be performed in 2 different ways:

  1. Frequency is measured by counting pulses over time period (997 ms). Method is used for frequencies higher than 100 Hz.
  2. Frequency is measured by measuring time between pulses. Method is used for frequencies lower than 100 Hz.

When 2kHz pulse counter is enabled, all other scenarios will ignore corresponding DIN state, except DIN1 which can be used to wakeup device from Deep Sleep.

Parameter values

System parameters (ID = 145).  Device/Available/Input port/Frequency:

Device DIN1 DIN2 DIN4
50Hz 2kHz 50Hz 2kHz 50Hz 2kHz
FMB110/FMB120/FMB130/FMB140 + +
FMB202/FMB204/FMB209 + +
FMB920/FMB910 + +
FMC130 + +
FMB207 +

Advanced pulse counter parameter in configurator

Advanced pulse counter.png