Template:FMB Auto Geofence settings: Difference between revisions
Atabasnikov (talk | contribs) mNo edit summary |
Atabasnikov (talk | contribs) mNo edit summary |
||
Line 1: | Line 1: | ||
[[Image:Fmb120_autogeofence.png|300px|right]] | [[Image:Fmb120_autogeofence.png|300px|right]] | ||
AutoGeofence is based on the last known position after the movement has stopped. You can be notified using this function if your car is taken away. The shape and size of | AutoGeofence is based on the last known position after the movement has stopped. You can be notified using this function if your car is taken away. The shape and size of Geofence zones are set by parameters. It is possible to state whether entering or leaving the geofence triggers an asynchronous message. | ||
AutoGeofencing options can be configured by following parameters as depicted in the right hand side figure | AutoGeofencing options can be configured by following parameters as depicted in the right hand side figure:<br/>Activation timeout defines the delay between the creation of AutoGeofence within set ''Radius'' value around vehicle's most recent position and when the ignition is off. Note that AutoGeofencing does not require entering coordinates, instead it requires GPS visibility. AutoGeofence can be deactivated by: | ||
* Digital Input 1 – If DIN1 voltage becomes equal or higher than 6.9 V. | * ''Digital Input 1'' – If DIN1 voltage becomes equal or higher than 6.9 V. | ||
* Digital Input 2 – If DIN2 voltage becomes equal or higher than 2.1 V. | * ''Digital Input 2'' – If DIN2 voltage becomes equal or higher than 2.1 V. | ||
* Digital Input 3 – If DIN3 voltage becomes equal or higher than 3.5 V. | * ''Digital Input 3'' – If DIN3 voltage becomes equal or higher than 3.5 V. | ||
* iButton – | * ''iButton'' – If authorized iButton is attached. | ||
* Power Voltage – | * ''Power Voltage'' – If power voltage becomes higher than low voltage level (defined in Ignition settings). | ||
* Engine RPM – If engine RPM value becomes higher than 0.<br/> | * ''Engine RPM'' – If engine RPM value becomes higher than 0.<br/> | ||
Enter Event | ''Enter Event'' and ''Exit Event'': Event generation take place on Geofence entrance and exit. ''Eventual Records'' is used to enable or disable Eventual Records functionality. |
Revision as of 12:59, 19 April 2018
AutoGeofence is based on the last known position after the movement has stopped. You can be notified using this function if your car is taken away. The shape and size of Geofence zones are set by parameters. It is possible to state whether entering or leaving the geofence triggers an asynchronous message.
AutoGeofencing options can be configured by following parameters as depicted in the right hand side figure:
Activation timeout defines the delay between the creation of AutoGeofence within set Radius value around vehicle's most recent position and when the ignition is off. Note that AutoGeofencing does not require entering coordinates, instead it requires GPS visibility. AutoGeofence can be deactivated by:
- Digital Input 1 – If DIN1 voltage becomes equal or higher than 6.9 V.
- Digital Input 2 – If DIN2 voltage becomes equal or higher than 2.1 V.
- Digital Input 3 – If DIN3 voltage becomes equal or higher than 3.5 V.
- iButton – If authorized iButton is attached.
- Power Voltage – If power voltage becomes higher than low voltage level (defined in Ignition settings).
- Engine RPM – If engine RPM value becomes higher than 0.
Enter Event and Exit Event: Event generation take place on Geofence entrance and exit. Eventual Records is used to enable or disable Eventual Records functionality.