TAT140 I/O settings: Difference between revisions
(Created page with "{{Template:TAT1XY_I/O_settings |model=TAT140 |section_fmb0= |txt_count=7 |txt_elems= |sms_text_fmb= }} Category:TAT140 Configuration") |
m (Protected "TAT140 I/O settings" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite))) |
(No difference)
|
Latest revision as of 12:24, 7 April 2023
Main Page > Autonomous Trackers > TAT140 > TAT140 Configuration > TAT140 I/O settingsWhen no I/O element is enabled, AVL packet comes with GNSS information only. After enabling I/O element(s) AVL packet contains current value(s) of enabled I/O element(s) along with GNSS information.
Input Name
I/O element name.
Current Value
If device is connected to Configurator all current I/O values are displayed in this column. Also I/O current values can be seen in Status→I/O Info tab.
Units
Units of measurement.
Priority
This field allows to enable I/O elements and setting them a priority so they are added to the data packet, which is sent to the server. By default 7 I/O elements with Low priority are enabled: GSM Signal, GNSS Status, GNSS PDOP, GNSS HDOP, Speed, Battery Voltage, Active GSM Operator
. All records made by TAT140 are regular, and regular packets are sent as low priority records.
Priority level (AVL packet priority) can be:
None Priority
Module doesn't make additional record.
Low Priority
Module makes an additional record with an indication that the event was caused by an I/O element change (depending onas Operands configuration).
High and Low Level
These levels define I/O value range. If I/O value enters or exits this range, TAT140 generates an event.
Event Only
When this is selected, I/O element status value will be appended only to eventual records, otherwise I/O element status value will appear in each AVL record.
Operands
Defines when to generate event: On Exit, On Entrance, On Both, Monitoring, On Hysteresis, On Change or On Delta Change.
Operand On Exit
Record is generated when input value leaves a range between low and high level limits.
Operand On Entrance
Record is generated when input value enters a range between low and high level limits.
Operand On Both
Record is generated by both On Exit and On Entrance operands' logic at same time.
Operand Monitoring
No event at all. Values are recorded only when other triggers worked.
Operand On Hysteresis
Record is generated when input value crosses the high limit value from below the low limit value or vice versa.
Operand On Change
Record is generated when input value changes.
Operand On Delta Change
Record is generated when input value changes and the absolute change becomes equal to or higher than the limit value.
Avg Const
If Avg Const value is 10, new value must be present for 1 second to register the change to a new value. Internal sampling is done every 40 ms, so 25 samples are taken per second. To configure 5 seconds of averaging multiply 10 by 5 yielding 50 as Avg Const value. The same logic works if the device is in Deep Sleep mode.
Averaging follows RC exponential curve, see image below:
For Boolean values of 5τ, values is used, that means value change is taken when new values is averaged to more than 99.3%.
NOTE: Average Constant is not used as an activation timer or delay timer. But it is used as a filter.
Event is generated at different times due to variations in voltage. Average constant is designed to filter jumps instead of event generation time.
For example: generation is set to happen at 14500mV, and actual voltage is set to 15000mV, that record will be generated earlier than 10s with avg const set to 100. This is because avg const is calculating time it takes for device to get to actual voltage (in this case 15000 mV), while device will be generating records when it hits 14500mV.
Send SMS To
Sends SMS notification about event to selected number from SMS/Call Settings GSM Predefined Numbers list if event priority is set to Low, High or Panic.
SMS Text
The SMS Text field can be altered and any text can be entered. Maximum message length is 160 symbols (numbers, letters and symbols in ASCII, except for comma “,”).
SMS Event Text may be either in default or composed format.
Default format:
Date, time, longitude, latitude, 'SMS text', value
Example:
2018/11/02 12:00:00 Lon:0.000000 Lat:0.000000 Alarm 1
Composed format:
Composed format may consist of text and defined commands which start with % symbol.
Supported commands:
Command | Description |
---|---|
imei | IMEI |
fw | Firmware version |
fullfw | Full firmware version |
modem | Modem firmware version |
gnss | GPS firmware version |
lat | Latitude (non-float value) |
lon | Longitude (non-float value) |
sat | Satellites in use |
time | Timestamp |
pdp | PDOP |
hdp | HDOP |
mov | Movement |
op | GSM operator |
spd | Speed |
sig | GSM signal |
slp | Sleep Mode |
cel | Cell ID |
lac | Area Code |
datetime | time in hh:mm:ss format |
val | Eventual IO value |
io'par_id' | Element value by parameter ID |
gmap | Google Maps link |
Composed text example:
%imei Movement %io50010
Event SMS text:
352094082828606 Movement 1