Difference between revisions of "EYE FUNCTIONALITIES"
Line 4: | Line 4: | ||
This page will describe EYE device functionalities, their value flow and required firmware and software versions, | This page will describe EYE device functionalities, their value flow and required firmware and software versions, | ||
− | =EYE APP 1.2.2-89= | + | ===EYE APP 1.2.2-89=== |
− | ==Search device with QR scan== | + | ===Search device with QR scan=== |
− | Now you can find devices with QR scan by pressing scan button [[File:EYE_APP_QR_BUTTON.png|frameless|25x25px]] and scanning device QR code. | + | '''Functionality''': Now you can find devices with QR scan by pressing scan button [[File:EYE_APP_QR_BUTTON.png|frameless|25x25px]] and scanning device QR code. |
− | |||
− | + | '''Firmware''': 1.2.1.R.0+ | |
− | |||
− | |||
− | + | '''Value''': Easier device management | |
− | |||
− | |||
− | + | '''Flow:''' 1. Tap [[File:EYE_APP_QR_BUTTON.png|frameless|25x25px]] 2. scan the QR code engraved onto EYE device <br><br>[[File:EYE_APP_QR_PRESS_BUTTON.png|frameless|250px]][[File:EYE_APP_QR_SCAN.png|frameless|250px]][[File:EYE_APP_QR_SCAN_EXAMPLE.png|frameless|250px]] | |
− | |||
− | <br><br>[[File: | ||
− | == | + | ===Customized Sensor Selection=== |
− | Users can | + | '''Functionality''': Users can disable sensors reading leaving only the sensors they require. |
− | |||
− | + | '''Firmware''': 1.2.10.R.4+ | |
− | + | '''Value''': Data saving, battery life can be expanded by disabling accelerometer. | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
+ | '''Flow:''' 1. Connect to EYE device 2. Click "configure" 3. Expand Active sensors tab 4. Uncheck sensors you want to deactivate 4. Save your configuration.<br><br>[[File:EYE_APP_CHOOSE_ONE_SENSORS.png|frameless|250px]][[File:EYE_APP_ONE_SENSOR_VIEW.png|frameless|250px]][[File:EYE_APP_CHOOSE_FOUR_SENSORS.png|frameless|250px]][[File:EYE_APP_FOUR_SENSOR_VIEW.png|frameless|250px]] | ||
+ | |||
+ | ===Auto-Disconnect Timer=== | ||
+ | '''Functionality''': After 2 minutes of inactivity, users will be automatically disconnected from the device. Before disconnection, you will have the option to maintain the connection. | ||
+ | |||
+ | '''Firmware''': 1.2.10.R.4+ | ||
+ | |||
+ | '''Value''': Enhanced user privacy and energy saving. | ||
+ | |||
+ | '''Flow:''' 1. Connect to EYE device 2. Do not perform any saving actions for 2 minutes.<br><br>[[File:EYE_APP_TWO_MINUTE_WAIT.png|frameless|250px]][[File:EYE_APP_DISCONNECTED_AFTER_TWO_MINUTES.png|frameless|250px]][[File:EYE_APP_DISCONNECTED_WHILE_CONFIGURING.png|frameless|250px]] | ||
+ | |||
+ | ===Visible battery voltage=== | ||
+ | '''Functionality''': Eye App now provides a clear and convenient readout of the battery's voltage level, keeping users informed about their device's power status. | ||
+ | |||
+ | '''Firmware''': 1.2.1.R.0+ | ||
+ | |||
+ | '''Value''': Keeping users informed about their device's power status. | ||
+ | |||
+ | '''Flow:''' 1. Expand sensor card in the overview screen or connect to the device<br><br>[[File:EYE_APP_VISIBLE_BATTERY_VOLTAGE.png|frameless|250px]] | ||
+ | |||
+ | ===12 characters name=== | ||
+ | '''Functionality''': Users can now assign names of up to 12 characters, | ||
+ | |||
+ | '''Firmware''': 1.2.1.R.0+ | ||
+ | |||
+ | '''Value''': A full MAC address can be used as the name. | ||
+ | |||
+ | '''Flow:''' 1. Connect to EYE device 2. Click "configure" 3. Expand Name settings drop down 4. Enter desired name 4. Save your configuration.<br>[[File:EYE APP 12 CHAR NAME.png|frameless|250px]] | ||
+ | |||
+ | ==<big>EYE APP 1.2.0-63</big>== | ||
+ | |||
+ | ===PIN code=== | ||
+ | '''Functionality''': Eye App will time-out users on for 5 minutes after 5 unsuccessful PIN attempts | ||
+ | |||
+ | '''Firmware''': 1.2.1.R.0 to 1.2.8.R.2 | ||
+ | |||
+ | '''Value''': Keeping users informed about their device's power status. | ||
+ | |||
+ | '''Flow:''' 1. Tap the selected device to connect to it 2. Enter PIN incorrectly, fail to enter PIN correctly 4 more times 3. wait for 5 min timeout a | ||
+ | |||
+ | [[File:Screenshot 20230503 165303 EYE APP edited.jpg|left|thumb|400x400px|link=https://wiki.teltonika-gps.com/view/File:Screenshot_20230503_165303_EYE_APP_edited.jpg]][[File:Screenshot 20230509 1518232 EYE APP.jpg|left|thumb|400x400px|link=https://wiki.teltonika-gps.com/view/File:Screenshot_20230509_1518232_EYE_APP.jpg]][[File:Screenshot 20230509 152802 EYE APP.jpg|left|thumb|400x400px|link=https://wiki.teltonika-gps.com/view/File:Screenshot_20230509_152802_EYE_APP.jpg]] | ||
Revision as of 15:39, 8 December 2023
Page Description
This page will describe EYE device functionalities, their value flow and required firmware and software versions,
EYE APP 1.2.2-89
Search device with QR scan
Functionality: Now you can find devices with QR scan by pressing scan button and scanning device QR code.
Firmware: 1.2.1.R.0+
Value: Easier device management
Flow: 1. Tap 2. scan the QR code engraved onto EYE device
Customized Sensor Selection
Functionality: Users can disable sensors reading leaving only the sensors they require.
Firmware: 1.2.10.R.4+
Value: Data saving, battery life can be expanded by disabling accelerometer.
Flow: 1. Connect to EYE device 2. Click "configure" 3. Expand Active sensors tab 4. Uncheck sensors you want to deactivate 4. Save your configuration.
Auto-Disconnect Timer
Functionality: After 2 minutes of inactivity, users will be automatically disconnected from the device. Before disconnection, you will have the option to maintain the connection.
Firmware: 1.2.10.R.4+
Value: Enhanced user privacy and energy saving.
Flow: 1. Connect to EYE device 2. Do not perform any saving actions for 2 minutes.
Visible battery voltage
Functionality: Eye App now provides a clear and convenient readout of the battery's voltage level, keeping users informed about their device's power status.
Firmware: 1.2.1.R.0+
Value: Keeping users informed about their device's power status.
Flow: 1. Expand sensor card in the overview screen or connect to the device
12 characters name
Functionality: Users can now assign names of up to 12 characters,
Firmware: 1.2.1.R.0+
Value: A full MAC address can be used as the name.
Flow: 1. Connect to EYE device 2. Click "configure" 3. Expand Name settings drop down 4. Enter desired name 4. Save your configuration.
EYE APP 1.2.0-63
PIN code
Functionality: Eye App will time-out users on for 5 minutes after 5 unsuccessful PIN attempts
Firmware: 1.2.1.R.0 to 1.2.8.R.2
Value: Keeping users informed about their device's power status.
Flow: 1. Tap the selected device to connect to it 2. Enter PIN incorrectly, fail to enter PIN correctly 4 more times 3. wait for 5 min timeout a
SW version requirements | EYE APP: 1.2.0-60+
Firmware: 1.2.9.R.8+ | ||||
---|---|---|---|---|---|
Short step desc. | Tap the selected device to connect to it | Enter PIN incorrectly | Fail to enter PIN correctly 4 more times | Wait for 5 min timeout and enter PIN incorrectly | Fail to enter PIN correctly 4 more times |
Additional desc. | Device is locked for 5 min but will allow to connect with PIN again after timeout | Device is locked with PUK code now and will remain so until correct PUK is entered, see PUK code unlock. | |||
Failed attempt at functionality visual |
PUK code unlock
SW version requirements | EYE APP: 1.2.0-60+
Firmware: 1.2.9.R.8+ | ||||
---|---|---|---|---|---|
Step No. | |||||
Short step desc. | Tap the blocked device to connect to it | Enter PUK | Connected | ||
Additional desc. | PIN automatically resets to default | ||||
Successful attempt at functionality visual | |||||
Step desc. | Tap the selected device to connect to it | Enter PUK incorrectly | Fail to enter PIN correctly 4 more times | ||
Additional desc. | PUK is rejected and you can only go back or enter correct PUK | ||||
Failed attempt at functionality visual |
Hibernate mode:
Wake up:
SW version requirements | Firmware: 1.2.9.R.8+ | ||||
---|---|---|---|---|---|
Step No. | 1-3 | 4 | |||
Short step desc. | Attach magnet to sleeping device and wait for LED to blink. | Device starts broacasting | |||
Additional desc. | Now device is discoverabled, scannable, connectable via BLE. | ||||
Successful attempt at functionality visual |
Send to sleep:
SW version requirements | EYE APP: 1.2.0-60+
Firmware: 1.2.9.R.8+ | ||
---|---|---|---|
Step No. | 1 | 2 | 3 |
Short step desc. | While connected and in overview tap "Send device to sleep" | Confirm your selection | Wait for EYE App to disconnect |
Additional desc. | Device is no longer connectable or findable until wake up step is performed. | ||
Successful attempt at functionality visual |