| PARAMETER NAME | PARAMETER ID (RELATED AVL ID) | DESCRIPTION | VALUES |
|---|---|---|---|
| Immobilizer | 11700 | Disables, or enables and sets priority of the event record generated upon successful or failed authorization attempts.Authorization source | 0 = Disable scenario. 1 = Low priority Device makes an additional record with indication of event cause. |
| Authorization source | 11703 | Selects the type of authorization element to be used. | 0 = No authorization selected. 1 = 1-Wire authorization selected. |
| Ignition OFF timeout (s) | 60068 | Sets the time in seconds after the ignition is turned off before the driver's authorization is automatically revoked. | Minimum value = 1 Maximum value = 65535 |
| Eventual records | 11701 | Enables feature status sending only when the event happens (an eventual record). When disabled, feature status will be sent with both eventual and periodical records. | 0 = Disable 1 = Enable |
| Bypass authorization | 11029 | Allows to bypass authorization when ignition is turned on and a duration expires. | 0 = Disabled 0-65535 = Enabled |
| Bypass authorization timeout (s) | 11029 | Sets duration which starts when ignition is turned on. When duration expires immobilizer is turned off, even if the user was not authenticated. | Minimum value = 1 Maximum value = 65535 |
| Output control | 65535 | Selects which Digital Output is used to control the immobilizer relay. | 0 = None DOUTs are disabled in this scenario. 1 = DOUT1 DOUT1 is enabled in this scenario. |