Parameters value types
System parameters
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1000 | U8 | 0 | 0 | 2 | 0 – Disabled | Sleep Settings |
1 – GPS Sleep | ||||||
2 – Deep Sleep | ||||||
200 | U8 | 1 | 1 | 3000 | - | Sleep Timeout |
1001 | U8 | 0 | 0 | 1 | 0 - 10V | Analog Input value range |
1 – 30V | ||||||
1002 | U8 | 1 | 0 | 3 | 0 - ignition | Stop Detection Source |
1 - Msensor | ||||||
2 - GPS | ||||||
3 - ignition + Msensor | ||||||
1003 | U8 | 0 | 0 | 1 | 0 - Disabled | Static Navigation |
1 – Enabled | ||||||
1004 | 0 | 0 | 2 | 0 – Power voltage | Ignition Source | |
1 – Digital input 1 | ||||||
2 – Msensor | ||||||
1005 | 30000 mV | 13000 mV | 30000 mV | High Voltage Level | ||
1006 | 13000 mV | 0 | 30000 mV | Low Voltage Level | ||
1008 | 0 | 0 | 1 | 0 - Manual | Ignition Detection | |
1 – Automatic | ||||||
1009 | U8 | 10 | 0 | 65535 | Ignition Detection Timeout | |
1007 | U8 | 60 | 0 | 65535 | GNSS FIX Timeout for Time Synchronization via NTP | |
201 | U8 | 0 | 0 | 1 | 0 - Disabled | Saving/Sending without time synchronization |
1 – Enabled | ||||||
202 | U8 | 0 | 0 | 2 | 0 – GNSS (all available) | Satellite System |
1 – GPS | ||||||
2 – GLONASS |